Determination of S, Ni, Cu in copper-nickel sulfide ores by total reflection X-ray fluorescence analysis: experience of participation in the interlaboratory comparisons

A. N. Zhilicheva, G. Pashkova, A. V. Karkhova, N. N. Ukhova, V. Chubarov
{"title":"Determination of S, Ni, Cu in copper-nickel sulfide ores by total reflection X-ray fluorescence analysis: experience of participation in the interlaboratory comparisons","authors":"A. N. Zhilicheva, G. Pashkova, A. V. Karkhova, N. N. Ukhova, V. Chubarov","doi":"10.26896/1028-6861-2024-90-7-8-16","DOIUrl":null,"url":null,"abstract":"The quality of the determination of S, Ni, Cu in copper-nickel sulfide ores was assessed in the framework of the program for interlaboratory comparative tests (ICT) using total reflection X-ray fluorescence analysis (TXRF) taking into account the criteria for methods for determining the chemical composition of mineral raw materials. Certified TXRF techniques for the analysis of mineral materials are absent, so the interlaboratory comparison test was used to control and improve the accuracy of measurements by TXRF. Powdered ore samples were prepared as suspensions by wet grinding: 100 mg of the powder, 4 ml of ultra-pure water and 250 μl of the Ga standard solution were milled using 20 g of ZrO2 balls 1 mm in diameter in the mixing mill for 10 minutes at a frequency of 20 Hz. The ratio of the intensities of the characteristic lines of the analyzed elements and the Ga internal standard was chosen as an analytical signal. To plot calibration curves, a set of ore reference samples was analyzed using certified procedures (atomic absorption spectrometry for Cu, Ni, gravimetry for S). The quality of the TXRF analysis was assessed by the value of Z-criterion. The measurement error did not exceed 5 rel. %. The relative percentage differences between the TXRF results and the results obtained in the interlaboratory study was less than 10%. The described method can be used for rapid analysis of copper-nickel sulfide ores.","PeriodicalId":13559,"journal":{"name":"Industrial laboratory. Diagnostics of materials","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Industrial laboratory. Diagnostics of materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26896/1028-6861-2024-90-7-8-16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The quality of the determination of S, Ni, Cu in copper-nickel sulfide ores was assessed in the framework of the program for interlaboratory comparative tests (ICT) using total reflection X-ray fluorescence analysis (TXRF) taking into account the criteria for methods for determining the chemical composition of mineral raw materials. Certified TXRF techniques for the analysis of mineral materials are absent, so the interlaboratory comparison test was used to control and improve the accuracy of measurements by TXRF. Powdered ore samples were prepared as suspensions by wet grinding: 100 mg of the powder, 4 ml of ultra-pure water and 250 μl of the Ga standard solution were milled using 20 g of ZrO2 balls 1 mm in diameter in the mixing mill for 10 minutes at a frequency of 20 Hz. The ratio of the intensities of the characteristic lines of the analyzed elements and the Ga internal standard was chosen as an analytical signal. To plot calibration curves, a set of ore reference samples was analyzed using certified procedures (atomic absorption spectrometry for Cu, Ni, gravimetry for S). The quality of the TXRF analysis was assessed by the value of Z-criterion. The measurement error did not exceed 5 rel. %. The relative percentage differences between the TXRF results and the results obtained in the interlaboratory study was less than 10%. The described method can be used for rapid analysis of copper-nickel sulfide ores.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用全反射 X 射线荧光分析法测定硫化铜镍矿石中的硒、镍、铜:参与实验室间比较的经验
在实验室间比较试验(ICT)计划框架内,利用全反射 X 射线荧光分析法(TXRF)对铜镍硫化矿中 S、Ni、Cu 的测定质量进行了评估,同时考虑到了矿物原料化学成分测定方法的标准。目前还没有用于分析矿物材料的经过认证的 TXRF 技术,因此采用实验室间比较试验来控制和提高 TXRF 测量的准确性。粉末矿石样品通过湿法研磨制备成悬浮液:将 100 毫克粉末、4 毫升超纯水和 250 微升 Ga 标准溶液在混合研磨机中用 20 克直径为 1 毫米的 ZrO2 球以 20 赫兹的频率研磨 10 分钟。分析元素和镓内标物的特征线强度之比被选为分析信号。为了绘制校准曲线,使用认证程序(铜、镍的原子吸收光谱法,S 的重力分析法)对一组矿石参考样品进行了分析。TXRF 分析的质量根据 Z 标准值进行评估。测量误差不超过 5%。TXRF 分析结果与实验室间研究结果之间的相对百分比差异小于 10%。所述方法可用于硫化铜镍矿的快速分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of the use of polyvinyl alcohol in the manufacture of pressed samples for X-ray fluorescence analysis Determination of the criterion for the morphological classification of etching pits formed in InSb single crystals grown by the Czochralski method in the crystallographic direction [111] and doped with tellurium The paradigm shift in mathematical methods of research Low cycle fracture resistance of the superalloy at single- and two-frequency modes of loading Fatigue fracture of 316L steel manufactured by selective laser melting method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1