{"title":"Ultrasonic localization method based on Chan‐WLS algorithm for detecting power transformer partial discharge faults by fibre optic F‐P sensing array","authors":"Hong Liu, Tianhe Yang, Zhixian Zhang, Haoyuan Tian, Yuxuan Song, Qiuxia Sun, Wei Wang, Yunjun Geng, Weigen Chen","doi":"10.1049/hve2.12472","DOIUrl":null,"url":null,"abstract":"Fibre optic F‐P sensor has become one of the mainstream detection methods for partial discharge faults due to their advantages of good insulation, high sensitivity, resistance to electromagnetic interference, simple structure and inexpensive pricing. The first‐order resonant frequency of the acoustically sensitive diaphragm of the F‐P sensor is given based on the theory of plate and shell vibration, and the fibre optic F‐P sensing array is designed based on the Fabry–Perot interference principle. A sensor installation method is also proposed for introducing a fibre optic F‐P probe into the power transformer interior using a fibre optic penetrator through flange at the power transformer oil change valve. A system of non‐linear equations is developed by utilising the time difference of arrival (TDOA) of the partial discharge ultrasound signal propagation to the F‐P sensing array. The Chan‐WLS algorithm is used to convert the non‐linear equations in the TDOA localisation method into a non‐linear optimisation problem to be solved and experimentally verified on the 220 kV real power transformer. The experimental results show that the error in the partial discharge fault localisation is solved based on the Chan‐WLS algorithm and the actual location is 20.27 cm, which is within the acceptable error.","PeriodicalId":48649,"journal":{"name":"High Voltage","volume":" 4","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Voltage","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1049/hve2.12472","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Fibre optic F‐P sensor has become one of the mainstream detection methods for partial discharge faults due to their advantages of good insulation, high sensitivity, resistance to electromagnetic interference, simple structure and inexpensive pricing. The first‐order resonant frequency of the acoustically sensitive diaphragm of the F‐P sensor is given based on the theory of plate and shell vibration, and the fibre optic F‐P sensing array is designed based on the Fabry–Perot interference principle. A sensor installation method is also proposed for introducing a fibre optic F‐P probe into the power transformer interior using a fibre optic penetrator through flange at the power transformer oil change valve. A system of non‐linear equations is developed by utilising the time difference of arrival (TDOA) of the partial discharge ultrasound signal propagation to the F‐P sensing array. The Chan‐WLS algorithm is used to convert the non‐linear equations in the TDOA localisation method into a non‐linear optimisation problem to be solved and experimentally verified on the 220 kV real power transformer. The experimental results show that the error in the partial discharge fault localisation is solved based on the Chan‐WLS algorithm and the actual location is 20.27 cm, which is within the acceptable error.
High VoltageEnergy-Energy Engineering and Power Technology
CiteScore
9.60
自引率
27.30%
发文量
97
审稿时长
21 weeks
期刊介绍:
High Voltage aims to attract original research papers and review articles. The scope covers high-voltage power engineering and high voltage applications, including experimental, computational (including simulation and modelling) and theoretical studies, which include:
Electrical Insulation
● Outdoor, indoor, solid, liquid and gas insulation
● Transient voltages and overvoltage protection
● Nano-dielectrics and new insulation materials
● Condition monitoring and maintenance
Discharge and plasmas, pulsed power
● Electrical discharge, plasma generation and applications
● Interactions of plasma with surfaces
● Pulsed power science and technology
High-field effects
● Computation, measurements of Intensive Electromagnetic Field
● Electromagnetic compatibility
● Biomedical effects
● Environmental effects and protection
High Voltage Engineering
● Design problems, testing and measuring techniques
● Equipment development and asset management
● Smart Grid, live line working
● AC/DC power electronics
● UHV power transmission
Special Issues. Call for papers:
Interface Charging Phenomena for Dielectric Materials - https://digital-library.theiet.org/files/HVE_CFP_ICP.pdf
Emerging Materials For High Voltage Applications - https://digital-library.theiet.org/files/HVE_CFP_EMHVA.pdf