Conventional PCR-based versus next-generation sequencing-based approach for T-cell receptor γ gene clonality assessment in mature T-cell lymphomas: A phase 3 diagnostic accuracy study

Riccardo Donelli, A. Gazzola, C. Mannu, Maryam Etebari, M. Navari, P. Piccaluga
{"title":"Conventional PCR-based versus next-generation sequencing-based approach for T-cell receptor γ gene clonality assessment in mature T-cell lymphomas: A phase 3 diagnostic accuracy study","authors":"Riccardo Donelli, A. Gazzola, C. Mannu, Maryam Etebari, M. Navari, P. Piccaluga","doi":"10.14440/jbm.2024.0002","DOIUrl":null,"url":null,"abstract":"Background: Clonality assessment is currently the major molecular analysis utilized to support the diagnosis of suspicious lymphoid malignancies. Clonal rearrangements of the V-J segments of T-cell receptor G chain locus (TCRγ or TRG) have been observed in almost all types of T neoplasms, such as T-cell-related non-Hodgkin lymphomas and leukemias. At present, the gold standard for clonality evaluation is multiplex polymerase chain reaction (PCR), plus subsequent capillary electrophoresis/heteroduplex analyses, and/or Sanger sequencing. This approach overcomes the problem with the conventional Southern blot hybridization and is more efficient, simple, fast, and reproducible. In the recent years, the new next-generation sequencing (NGS) technologies provided alternative techniques for the analysis of antigen receptors genes, which presented several advantages, such as increased efficiency, specificity (SP), sensitivity (ST), resolution, and objectivity of the results, leading to a better classification, stratification, and monitoring of lymphoid malignancies. Nonetheless, these technologies are still far from being the new gold standard since further studies are warranted to prove their utility. The present study aimed to assess the diagnostic accuracy of these two methods by comparing a commercial NGS-based assay for the evaluation of TRG locus with the gold standard PCR-based one, to fulfill the requirements of a phase 3 diagnostic accuracy study. Methods: We assessed the TRG gene rearrangements in 72 cases using the conventional and highly-validated PCR-based assay proposed by EuroClonality consortium, an alternative commercial PCR-based assay, namely, IdentiClone® TCR Gamma Gene Rearrangement Assay 2.0, and a commercial NGS-based assay, that is, Invivoscribe LymphoTrack® Dx MiSeq® (both by Invivoscribe Technologies Inc., San Diego, CA, USA), to determine the diagnostic accuracy of the latter, and compare them with reference diagnoses made based on observation of clinical manifestations, cytohistological, and immunohistochemical analyses. Statistical values were calculated using the Oxford CATmaker software package. Results: Using standardized criteria of interpretation, the obtained results showed a diagnostic accuracy of 90.3% (correspondence in 65 out of 72 cases) of the test under investigation, with a ST of 86%, a SP of 95%, a positive predicting value of 94%, and a negative predicting value of 88%, demonstrating that Invivoscribe LymphoTrack® Dx MiSeq® assay had high efficiency and reliability in detecting clonal TRG gene rearrangements in T-cell non-Hodgkin lymphomas. Conclusions: This diagnostic accuracy study yielded comparable results using a validated PCR-based approach and a new NGS-based one. Subsequent studies and cost-effectiveness evaluation are needed to put the NGS-based clonality assessment into routine diagnostic practice.\n","PeriodicalId":73618,"journal":{"name":"Journal of biological methods","volume":"54 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biological methods","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14440/jbm.2024.0002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Clonality assessment is currently the major molecular analysis utilized to support the diagnosis of suspicious lymphoid malignancies. Clonal rearrangements of the V-J segments of T-cell receptor G chain locus (TCRγ or TRG) have been observed in almost all types of T neoplasms, such as T-cell-related non-Hodgkin lymphomas and leukemias. At present, the gold standard for clonality evaluation is multiplex polymerase chain reaction (PCR), plus subsequent capillary electrophoresis/heteroduplex analyses, and/or Sanger sequencing. This approach overcomes the problem with the conventional Southern blot hybridization and is more efficient, simple, fast, and reproducible. In the recent years, the new next-generation sequencing (NGS) technologies provided alternative techniques for the analysis of antigen receptors genes, which presented several advantages, such as increased efficiency, specificity (SP), sensitivity (ST), resolution, and objectivity of the results, leading to a better classification, stratification, and monitoring of lymphoid malignancies. Nonetheless, these technologies are still far from being the new gold standard since further studies are warranted to prove their utility. The present study aimed to assess the diagnostic accuracy of these two methods by comparing a commercial NGS-based assay for the evaluation of TRG locus with the gold standard PCR-based one, to fulfill the requirements of a phase 3 diagnostic accuracy study. Methods: We assessed the TRG gene rearrangements in 72 cases using the conventional and highly-validated PCR-based assay proposed by EuroClonality consortium, an alternative commercial PCR-based assay, namely, IdentiClone® TCR Gamma Gene Rearrangement Assay 2.0, and a commercial NGS-based assay, that is, Invivoscribe LymphoTrack® Dx MiSeq® (both by Invivoscribe Technologies Inc., San Diego, CA, USA), to determine the diagnostic accuracy of the latter, and compare them with reference diagnoses made based on observation of clinical manifestations, cytohistological, and immunohistochemical analyses. Statistical values were calculated using the Oxford CATmaker software package. Results: Using standardized criteria of interpretation, the obtained results showed a diagnostic accuracy of 90.3% (correspondence in 65 out of 72 cases) of the test under investigation, with a ST of 86%, a SP of 95%, a positive predicting value of 94%, and a negative predicting value of 88%, demonstrating that Invivoscribe LymphoTrack® Dx MiSeq® assay had high efficiency and reliability in detecting clonal TRG gene rearrangements in T-cell non-Hodgkin lymphomas. Conclusions: This diagnostic accuracy study yielded comparable results using a validated PCR-based approach and a new NGS-based one. Subsequent studies and cost-effectiveness evaluation are needed to put the NGS-based clonality assessment into routine diagnostic practice.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
成熟T细胞淋巴瘤T细胞受体γ基因克隆性评估中基于PCR的传统方法与基于新一代测序的方法的比较:3期诊断准确性研究
背景:克隆性评估是目前用于支持诊断可疑淋巴恶性肿瘤的主要分子分析方法。在几乎所有类型的 T 细胞肿瘤(如 T 细胞相关的非霍奇金淋巴瘤和白血病)中都可观察到 T 细胞受体 G 链基因座(TCRγ 或 TRG)V-J 段的克隆重排。目前,克隆性评估的黄金标准是多重聚合酶链反应(PCR),以及随后的毛细管电泳/双链分析和/或桑格测序。这种方法克服了传统 Southern 印迹杂交的问题,更高效、简单、快速、可重复。近年来,新的新一代测序(NGS)技术为抗原受体基因分析提供了替代技术,具有效率高、特异性(SP)强、灵敏度(ST)高、分辨率高、结果客观等优点,可更好地对淋巴恶性肿瘤进行分类、分层和监测。尽管如此,这些技术仍远未成为新的金标准,因为还需要进一步的研究来证明它们的实用性。本研究旨在评估这两种方法的诊断准确性,将基于 NGS 的商用检测方法与基于 PCR 的金标准检测方法进行比较,以评估 TRG 基因座的诊断准确性,从而满足 3 期诊断准确性研究的要求。方法:我们评估了 72 个病例的 TRG 基因重排情况,分别使用了欧洲克隆联盟(EuroClonality consortium)提出的经过高度验证的传统 PCR 检测方法、另一种基于 PCR 的商业检测方法 IdentiClone® TCR Gamma 基因重排检测 2.0 和基于 NGS 的商业检测方法 Invivoscribe LymphoTrack® Dx MiSeq®(均由 Invivoscribe Technologies Inc、美国加利福尼亚州圣迭戈市),以确定后者的诊断准确性,并将其与根据临床表现观察、细胞组织学和免疫组化分析做出的参考诊断进行比较。统计值使用牛津 CATmaker 软件包进行计算。结果:使用标准化解释标准得出的结果显示,该检测方法的诊断准确率为 90.3%(72 个病例中有 65 个对应),ST 为 86%,SP 为 95%,阳性预测值为 94%,阴性预测值为 88%,表明 Invivoscribe LymphoTrack® Dx MiSeq® 检测方法在检测 T 细胞非霍奇金淋巴瘤的克隆 TRG 基因重排方面具有很高的效率和可靠性。结论:这项诊断准确性研究使用基于 PCR 的有效方法和基于 NGS 的新方法得出了相似的结果。要将基于 NGS 的克隆性评估应用到常规诊断实践中,还需要进行后续研究和成本效益评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reappraisal of the fundamental mechanisms of the sHA14-1 molecule as a Bcl-2/Bcl-XL ligand in the context of anticancer therapy: A cell biological study. Combined T1-weighted MRI and diffusion MRI tractography of paraventricular, locus coeruleus, and dorsal vagal complex connectivity in brainstem-hypothalamic nuclei. Hematological parameters of the European hake (Merluccius merluccius) in Toroneos Gulf, northern Greece: A case study. Advanced UltraTech approach for distinguishing granulomatous from non-granulomatous corneal endothelial exudates in autoimmune rheumatic anterior uveitis. Extraordinary variance in meta-analysis of venom toxicity of 160 most lethal ophidians and guidelines for estimating human lethal dose range.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1