The validity and reliability of the My Jump 2 application for trained junior and adult athletes

IF 0.8 4区 医学 Q4 SPORT SCIENCES Science & Sports Pub Date : 2024-08-01 DOI:10.1016/j.scispo.2023.08.007
{"title":"The validity and reliability of the My Jump 2 application for trained junior and adult athletes","authors":"","doi":"10.1016/j.scispo.2023.08.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>To examine the reliability, validity, and usefulness of the My Jump 2 application compared to an infrared platform photoelectric cell system in young and adult professional athletes.</p></div><div><h3>Equipment and methods</h3><p>Twenty-one junior athletes (16.0<!--> <!-->±<!--> <!-->1.8 years old) and nineteen professional adults (20.7<!--> <!-->±<!--> <!-->7.7 years old) performed six countermovement jumps (CMJ) and six squat jumps (SJ) measured simultaneously by the optical jump device (infrared platform) and the My Jump 2 application.</p></div><div><h3>Results</h3><p>The results revealed very high correlations between the My Jump 2 application and the infrared platform photoelectric cell system for both SJ (r<!--> <!-->=<!--> <!-->0.99, <em>P</em> <!-->&lt;<!--> <span>0.001) and CMJ (r</span> <!-->=<!--> <!-->0.99, <em>P</em> <!-->&lt;<!--> <!-->0.001). Furthermore, high reproducibility (ICC<!--> <!-->&gt;<!--> <!-->0.86) and low coefficients of variation (CV<!--> <!-->&lt;<!--> <!-->5%) were observed for all measurements.</p></div><div><h3>Conclusion</h3><p>My Jump 2 application presents excellent validity, reliability, and applicability for SJ and CMJ jump assessments in both young male athletes and professional adults.</p></div><div><h3>Objectif</h3><p>Il s’agit d’examiner la fiabilité, la validité et l’utilité de l’application My Jump 2 par comparaison à un système de cellules photoélectriques à plate-forme infrarouge, chez des athlètes professionnels jeunes et adultes.</p></div><div><h3>Matériels et méthodes</h3><p>Vingt et un athlètes juniors (16,0<!--> <!-->±<!--> <!-->1,8 ans) et dix-neuf adultes professionnels (20,7<!--> <!-->±<!--> <!-->7,7 ans) ont exécuté six sauts en contre-mouvement (CMJ) et six sauts en squat (SJ) mesurés simultanément par le dispositif de saut optique (plate-forme infrarouge) et l’application My Jump 2.</p></div><div><h3>Résultats</h3><p>Les résultats ont révélé des corrélations très élevées entre l’application My Jump 2 et le système de cellules photoélectriques à plate-forme infrarouge pour SJ (r<!--> <!-->=<!--> <!-->0,99, <em>p</em> <!-->&lt;<!--> <!-->0,001) et CMJ (r<!--> <!-->=<!--> <!-->0,99, <em>p</em> <!-->&lt;<!--> <!-->0,001). De plus, une reproductibilité élevée (ICC<!--> <!-->&gt;<!--> <!-->0,86) et de faibles coefficients de variation (CV<!--> <!-->&lt;<!--> <!-->5 %) ont été observés pour toutes les mesures.</p></div><div><h3>Conclusion</h3><p>L’application My Jump 2 présente une validité, une fiabilité et une applicabilité excellentes pour les évaluations de saut SJ et CMJ chez les jeunes athlètes masculins et les adultes professionnels.</p></div>","PeriodicalId":21728,"journal":{"name":"Science & Sports","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science & Sports","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0765159724000996","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To examine the reliability, validity, and usefulness of the My Jump 2 application compared to an infrared platform photoelectric cell system in young and adult professional athletes.

Equipment and methods

Twenty-one junior athletes (16.0 ± 1.8 years old) and nineteen professional adults (20.7 ± 7.7 years old) performed six countermovement jumps (CMJ) and six squat jumps (SJ) measured simultaneously by the optical jump device (infrared platform) and the My Jump 2 application.

Results

The results revealed very high correlations between the My Jump 2 application and the infrared platform photoelectric cell system for both SJ (r = 0.99, P < 0.001) and CMJ (r = 0.99, P < 0.001). Furthermore, high reproducibility (ICC > 0.86) and low coefficients of variation (CV < 5%) were observed for all measurements.

Conclusion

My Jump 2 application presents excellent validity, reliability, and applicability for SJ and CMJ jump assessments in both young male athletes and professional adults.

Objectif

Il s’agit d’examiner la fiabilité, la validité et l’utilité de l’application My Jump 2 par comparaison à un système de cellules photoélectriques à plate-forme infrarouge, chez des athlètes professionnels jeunes et adultes.

Matériels et méthodes

Vingt et un athlètes juniors (16,0 ± 1,8 ans) et dix-neuf adultes professionnels (20,7 ± 7,7 ans) ont exécuté six sauts en contre-mouvement (CMJ) et six sauts en squat (SJ) mesurés simultanément par le dispositif de saut optique (plate-forme infrarouge) et l’application My Jump 2.

Résultats

Les résultats ont révélé des corrélations très élevées entre l’application My Jump 2 et le système de cellules photoélectriques à plate-forme infrarouge pour SJ (r = 0,99, p < 0,001) et CMJ (r = 0,99, p < 0,001). De plus, une reproductibilité élevée (ICC > 0,86) et de faibles coefficients de variation (CV < 5 %) ont été observés pour toutes les mesures.

Conclusion

L’application My Jump 2 présente une validité, une fiabilité et une applicabilité excellentes pour les évaluations de saut SJ et CMJ chez les jeunes athlètes masculins et les adultes professionnels.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
针对训练有素的青少年和成年运动员的 "我的跳跃 2 "应用程序的有效性和可靠性
设备和方法21 名青少年运动员(16.0 ± 1.8 岁)和 19 名成年专业运动员(20.7 ± 7.结果结果表明,"我的跳跃 2 "应用程序与红外平台光电传感器系统在 SJ(r = 0.99,P <;0.001)和 CMJ(r = 0.99,P <;0.001)方面的相关性非常高。此外,所有测量结果的再现性(ICC >0.86)都很高,变异系数(CV <5%)也很低。目的研究 My Jump 2 应用程序与红外线平台光电管系统在年轻和成年专业运动员中的可靠性、有效性和适用性。材料和方法21 名青少年运动员(16.0 ± 1.8 岁)和 19 名成年专业运动员(20.7 ± 7.7 岁)分别进行了六次反身跳(CMJ)和六次蹲跳(SJ),同时用光学跳跃装置(红外平台)和 My Jump 2 应用程序进行测量。结果结果显示,"我的跳跃 2 "应用程序和红外线平台光电管系统对 SJ(r = 0.99,p < 0.001)和 CMJ(r = 0.99,p < 0.001)的相关性非常高。结论 My Jump 2 应用程序在年轻男性运动员和专业成年人的 SJ 和 CMJ 跳远评估中具有出色的有效性、可靠性和适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Science & Sports
Science & Sports 社会科学-运动科学
CiteScore
1.50
自引率
18.20%
发文量
143
审稿时长
19.7 weeks
期刊介绍: Science & Sports is a peer-reviewed journal, publishing worldwide high-quality and impactful papers of medical, scientific and applied technical research in the different fields of sports and physical activities: sport medicine, exercise physiology, sport physiology and performance, nutrition, traumatology relating to sport, rehabilitation or adapted physical activities. It facilitates the transfer of knowledge and technology between the clinic, research and practice in physical and athletic activity.
期刊最新文献
Editorial Board Incidental physical activity and circulating irisin levels in the adult population: A systematic review and meta-analysis État des lieux de la prévention antidopage chez les joueuses et joueurs de rugby amateurs de 15 ans et plus, licenciés en Eure-et-Loir Hydration status of esports players in a live competition Standardization of evaluation and exercise prescription for deep water running with normobaric hypoxia exposure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1