An unusual retrieval of semi-detached stent: A multistage procedure

Mahmut Ekrem Cunetoglu, Volkan Kozluca, Bilge Nazar Ates, Cagdas Ozdol, Ali Timucin Altin
{"title":"An unusual retrieval of semi-detached stent: A multistage procedure","authors":"Mahmut Ekrem Cunetoglu,&nbsp;Volkan Kozluca,&nbsp;Bilge Nazar Ates,&nbsp;Cagdas Ozdol,&nbsp;Ali Timucin Altin","doi":"10.1016/j.crmic.2024.100042","DOIUrl":null,"url":null,"abstract":"<div><p>The occurrence of coronary artery stent detachment from the balloon is infrequent during cardiac procedures, although it poses a potentially grave consequence. It can result in the development of induced coronary thrombosis, myocardial infarction, and disruption of peripheral and cerebral blood circulation. There is no universally accepted procedure for extracting the stent, however, several techniques and their combinations can be employed based on the specific circumstances of the case and the ingenuity of the operator. Various techniques were employed to extract the stripped stent in the right coronary artery (RCA), and ultimately it was effectively retrieved using an untested approach.</p></div>","PeriodicalId":100217,"journal":{"name":"Cardiovascular Revascularization Medicine: Interesting Cases","volume":"3 ","pages":"Article 100042"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2950275624000388/pdfft?md5=10fa7b9c42f39a3e2c4337efaa7d6877&pid=1-s2.0-S2950275624000388-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Revascularization Medicine: Interesting Cases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2950275624000388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The occurrence of coronary artery stent detachment from the balloon is infrequent during cardiac procedures, although it poses a potentially grave consequence. It can result in the development of induced coronary thrombosis, myocardial infarction, and disruption of peripheral and cerebral blood circulation. There is no universally accepted procedure for extracting the stent, however, several techniques and their combinations can be employed based on the specific circumstances of the case and the ingenuity of the operator. Various techniques were employed to extract the stripped stent in the right coronary artery (RCA), and ultimately it was effectively retrieved using an untested approach.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不寻常的半脱落支架取出术:多阶段手术
在心脏手术过程中,冠状动脉支架从球囊脱落的情况并不常见,但它可能造成严重后果。它可能导致诱发冠状动脉血栓形成、心肌梗死以及外周和大脑血液循环的破坏。目前还没有公认的提取支架的程序,但可以根据具体情况和操作者的聪明才智采用多种技术及其组合。为了取出右冠状动脉(RCA)中剥离的支架,我们采用了多种技术,最终使用一种未经测试的方法有效地取出了支架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Challenges in managing vascular complications and iatrogenic injuries in end-stage renal disease: A case report Percutaneous coronary intervention of ostial left main coronary artery chronic total occlusion Abandoned guidewire recapture from aortic root using “Guidewire twirling technique” Inverted left atrial appendage developing after mitral valve replacement surgery An enigmatic presentation of surgical bioprosthetic aortic valve stenosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1