{"title":"Endobronchial Closure for Peripheral Pulmonary Air Leakage.","authors":"Shoji Okado, Shota Nakamura, Keiyu Sato, Harushi Ueno, Takayasu Ito, Kazuhide Sato, Shotaro Okachi, Yohei Uehara, Misa Matsumoto, Natsumi Shimazaki, Katsuya Miyagawa, Toyofumi Fengshi Chen-Yoshikawa","doi":"10.1159/000540652","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>A minimally invasive alternative to surgery for treating pneumothorax has been developed, aiming to reduce risks while maintaining efficacy. This study conducted basic experiments using ex vivo and in vivo pig lung employing a super-thin catheter for treatment. This new device injects fibrin glue directly into the responsible lesion to close the air leak, which has two features: thin design and double-lumen.</p><p><strong>Methods: </strong>The experimental setup involved utilizing trachea and both lung specimens from pigs under positive pressure ventilation. To simulate pneumothorax, artificial fistulas were created on the lung surfaces. The super-thin catheter, guided through a bronchoscope near the fistula, was used to embolize the peripheral bronchus by injecting a fibrin preparation. Then, an air leak test was conducted afterward to assess the efficacy of the treatment. Additionally, a similar pneumothorax model was induced in alive pig under general anesthesia to evaluate its curability.</p><p><strong>Results: </strong>In the extracted pig lungs, embolization was performed in 21 cases, resulting in the cessation of air leaks in 19 cases, corresponding to a 90.5% cure rate. Notably, no major adverse events occurred with the treatment devices. Similarly, in living pigs, pneumothorax was successfully treated, with no recurrence observed up to the seventh postoperative day.</p><p><strong>Conclusion: </strong>The novel treatment device utilizing a super-thin catheter offers a minimally invasive and highly curative option for pneumothorax. These promising results suggest the potential for further development and human clinical trials, which could revolutionize the treatment of pneumothorax, reducing risks and improving outcomes.</p>","PeriodicalId":21048,"journal":{"name":"Respiration","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiration","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000540652","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: A minimally invasive alternative to surgery for treating pneumothorax has been developed, aiming to reduce risks while maintaining efficacy. This study conducted basic experiments using ex vivo and in vivo pig lung employing a super-thin catheter for treatment. This new device injects fibrin glue directly into the responsible lesion to close the air leak, which has two features: thin design and double-lumen.
Methods: The experimental setup involved utilizing trachea and both lung specimens from pigs under positive pressure ventilation. To simulate pneumothorax, artificial fistulas were created on the lung surfaces. The super-thin catheter, guided through a bronchoscope near the fistula, was used to embolize the peripheral bronchus by injecting a fibrin preparation. Then, an air leak test was conducted afterward to assess the efficacy of the treatment. Additionally, a similar pneumothorax model was induced in alive pig under general anesthesia to evaluate its curability.
Results: In the extracted pig lungs, embolization was performed in 21 cases, resulting in the cessation of air leaks in 19 cases, corresponding to a 90.5% cure rate. Notably, no major adverse events occurred with the treatment devices. Similarly, in living pigs, pneumothorax was successfully treated, with no recurrence observed up to the seventh postoperative day.
Conclusion: The novel treatment device utilizing a super-thin catheter offers a minimally invasive and highly curative option for pneumothorax. These promising results suggest the potential for further development and human clinical trials, which could revolutionize the treatment of pneumothorax, reducing risks and improving outcomes.
期刊介绍:
''Respiration'' brings together the results of both clinical and experimental investigations on all aspects of the respiratory system in health and disease. Clinical improvements in the diagnosis and treatment of chest and lung diseases are covered, as are the latest findings in physiology, biochemistry, pathology, immunology and pharmacology. The journal includes classic features such as editorials that accompany original articles in clinical and basic science research, reviews and letters to the editor. Further sections are: Technical Notes, The Eye Catcher, What’s Your Diagnosis?, The Opinion Corner, New Drugs in Respiratory Medicine, New Insights from Clinical Practice and Guidelines. ''Respiration'' is the official journal of the Swiss Society for Pneumology (SGP) and also home to the European Association for Bronchology and Interventional Pulmonology (EABIP), which occupies a dedicated section on Interventional Pulmonology in the journal. This modern mix of different features and a stringent peer-review process by a dedicated editorial board make ''Respiration'' a complete guide to progress in thoracic medicine.