Variable-density velocity-selective magnetization preparation for non-contrast-enhanced peripheral MR angiography.

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL Physical and Engineering Sciences in Medicine Pub Date : 2024-12-01 Epub Date: 2024-07-30 DOI:10.1007/s13246-024-01464-3
Minyoung Kim, Inpyeong Hwang, Seung Hong Choi, Jaeseok Park, Taehoon Shin
{"title":"Variable-density velocity-selective magnetization preparation for non-contrast-enhanced peripheral MR angiography.","authors":"Minyoung Kim, Inpyeong Hwang, Seung Hong Choi, Jaeseok Park, Taehoon Shin","doi":"10.1007/s13246-024-01464-3","DOIUrl":null,"url":null,"abstract":"<p><p>Velocity-selective (VS) magnetization preparation has shown great promise for non-contrast-enhanced (NCE) magnetic resonance angiography (MRA) with the ability to generate positive angiographic contrast directly using a single 3D acquisition. However, existing VS-MRA methods have an issue of aliased saturation around a certain velocity, known as velocity field-of-view (vFOV), which can cause undesired signal loss in arteries. This study aimed to develop a new version of the VS preparation pulse sequence that overcomes the aliased saturation problem in conventional VS preparation. Utilizing the fact that an excitation profile is the Fourier transform of excitation k-space sampling, we sampled the k-space in a non-uniform fashion by scaling gradient pulses accordingly to have aliased excitation diffused over velocity. The variable density sampling function was numerically optimized to maximize the average of the velocity passband signal while minimizing its variance. The optimized variable density VS magnetization was validated through Bloch simulations and applied to peripheral NCE MRA in healthy subjects. The in-vivo experiments showed that the proposed variable density VS-MRA significantly lowered arterial signal loss observed in conventional VS-MRA, as evidenced by a higher arterial signal-to-noise ratio (58.50 ± 14.29 vs. 55.54 ± 12.32; p < 0.05) and improved artery-to-background contrast-to-noise ratio (22.75 ± 7.57 vs. 20.60 ± 6.51; p < 0.05).</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":" ","pages":"1763-1771"},"PeriodicalIF":2.4000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-024-01464-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Velocity-selective (VS) magnetization preparation has shown great promise for non-contrast-enhanced (NCE) magnetic resonance angiography (MRA) with the ability to generate positive angiographic contrast directly using a single 3D acquisition. However, existing VS-MRA methods have an issue of aliased saturation around a certain velocity, known as velocity field-of-view (vFOV), which can cause undesired signal loss in arteries. This study aimed to develop a new version of the VS preparation pulse sequence that overcomes the aliased saturation problem in conventional VS preparation. Utilizing the fact that an excitation profile is the Fourier transform of excitation k-space sampling, we sampled the k-space in a non-uniform fashion by scaling gradient pulses accordingly to have aliased excitation diffused over velocity. The variable density sampling function was numerically optimized to maximize the average of the velocity passband signal while minimizing its variance. The optimized variable density VS magnetization was validated through Bloch simulations and applied to peripheral NCE MRA in healthy subjects. The in-vivo experiments showed that the proposed variable density VS-MRA significantly lowered arterial signal loss observed in conventional VS-MRA, as evidenced by a higher arterial signal-to-noise ratio (58.50 ± 14.29 vs. 55.54 ± 12.32; p < 0.05) and improved artery-to-background contrast-to-noise ratio (22.75 ± 7.57 vs. 20.60 ± 6.51; p < 0.05).

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于非对比度增强外周磁共振血管造影的可变密度速度选择性磁化准备。
速度选择性(VS)磁化准备在非对比度增强(NCE)磁共振血管造影(MRA)中大有可为,它能通过一次三维采集直接生成正血管造影对比度。然而,现有的 VS-MRA 方法存在一个问题,即在一定速度(称为速度视场(vFOV))周围存在混叠饱和,这会导致动脉中出现不希望出现的信号丢失。本研究旨在开发一种新版 VS 准备脉冲序列,以克服传统 VS 准备中的混叠饱和问题。利用激发曲线是激发 k 空间采样的傅立叶变换这一事实,我们通过相应缩放梯度脉冲对 k 空间进行非均匀采样,使混叠激发在速度上扩散。变密度采样函数经过数值优化,使速度通带信号的平均值最大化,同时使其方差最小化。通过布洛赫模拟验证了优化的可变密度 VS 磁化,并将其应用于健康受试者的外周 NCE MRA。体内实验表明,所提出的可变密度 VS-MRA 显著降低了传统 VS-MRA 中观察到的动脉信号损失,更高的动脉信噪比(58.50 ± 14.29 vs. 55.54 ± 12.32;p<0.05)证明了这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
期刊最新文献
Autoencoder based data clustering for identifying anomalous repetitive hand movements, and behavioral transition patterns in children. Guidance on selecting and evaluating AI auto-segmentation systems in clinical radiotherapy: insights from a six-vendor analysis. Evaluating the prognostic value of radiomics and clinical features in metastatic prostate cancer using [68Ga]Ga-PSMA-11 PET/CT. In-silico evaluation of the effect of set-up errors on dose delivery during mouse irradiations with a Cs-137 cell irradiator-based collimator system. Use of a virtual phantom to assess the capability of a treatment planning system to perform magnetic resonance image distortion correction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1