Intrarater and Interrater Reliability of Quantitative Ultrasound Speed of Sound by Trained Raters at the Distal Radius in Postmenopausal Women.

IF 1.5 4区 医学 Q4 GERIATRICS & GERONTOLOGY Journal of Geriatric Physical Therapy Pub Date : 2024-10-01 Epub Date: 2024-09-18 DOI:10.1519/JPT.0000000000000417
Cynthia J Watson, Matthew J de Ruig, Kent T Saunders
{"title":"Intrarater and Interrater Reliability of Quantitative Ultrasound Speed of Sound by Trained Raters at the Distal Radius in Postmenopausal Women.","authors":"Cynthia J Watson, Matthew J de Ruig, Kent T Saunders","doi":"10.1519/JPT.0000000000000417","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>Quantitative ultrasound (QUS) performed at the distal radius shows potential as an effective tool for evaluating fracture risk, especially in postmenopausal women, but the reliability of this tool has not been reported in this patient population. This study investigated the within-day intrarater and interrater reliability of trained raters performing QUS measures at the distal radius of postmenopausal community-dwelling women.</p><p><strong>Methods: </strong>Eighteen women between the ages of 56 and 87 years were recruited from senior centers in the Greenville area of South Carolina and consented to participate. A QUS bone sonometer was used in this study; the trained raters performed 3 repeated speed of sound (SOS) measures at the nondominant radius of each participant on the same day. Intraclass correlation coefficients (ICCs) were calculated (model 3,1 for intrarater and 2,3 for interrater reliability) to determine the reliability within and between raters. In addition, we calculated the standard error of measurement (SEM) and the minimal detectable change at 95% confidence interval (MDC 95 ).</p><p><strong>Results: </strong>The within-day intrarater reliability was excellent for both physical therapist raters (ICC (3,1) ranging from 0.93 to 0.91). The SEM and MDC for the within-day intrarater reliability measures were small for both raters (SEM = 36.79-38.75 or 0.92%-0.97% of the pooled mean; MDC 95  = 101.99-107.40). The interrater reliability for SOS measurements using radial QUS was good with an ICC (2,3) of 0.77 (95% CI, 0.36-0.92) for 3 averaged measures. The SEM and MDC were larger for the interrater reliability measures (SEM = 62.79 or 1.57% of the pooled mean; MDC 95  = 174.05).</p><p><strong>Conclusions: </strong>Quantitative ultrasound SOS measurement at the distal radius showed excellent within-day intrarater and good interrater (when 3 measures were averaged) reliability in community-dwelling postmenopausal women. The SEM and MDC 95 were also low for interrater reliability when a mean of 3 trials was used. This study is the first to demonstrate that this particular QUS device at the radius may be a reliable fracture risk screening tool for postmenopausal women.</p>","PeriodicalId":49035,"journal":{"name":"Journal of Geriatric Physical Therapy","volume":" ","pages":"E159-E166"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Geriatric Physical Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1519/JPT.0000000000000417","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/18 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"GERIATRICS & GERONTOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: Quantitative ultrasound (QUS) performed at the distal radius shows potential as an effective tool for evaluating fracture risk, especially in postmenopausal women, but the reliability of this tool has not been reported in this patient population. This study investigated the within-day intrarater and interrater reliability of trained raters performing QUS measures at the distal radius of postmenopausal community-dwelling women.

Methods: Eighteen women between the ages of 56 and 87 years were recruited from senior centers in the Greenville area of South Carolina and consented to participate. A QUS bone sonometer was used in this study; the trained raters performed 3 repeated speed of sound (SOS) measures at the nondominant radius of each participant on the same day. Intraclass correlation coefficients (ICCs) were calculated (model 3,1 for intrarater and 2,3 for interrater reliability) to determine the reliability within and between raters. In addition, we calculated the standard error of measurement (SEM) and the minimal detectable change at 95% confidence interval (MDC 95 ).

Results: The within-day intrarater reliability was excellent for both physical therapist raters (ICC (3,1) ranging from 0.93 to 0.91). The SEM and MDC for the within-day intrarater reliability measures were small for both raters (SEM = 36.79-38.75 or 0.92%-0.97% of the pooled mean; MDC 95  = 101.99-107.40). The interrater reliability for SOS measurements using radial QUS was good with an ICC (2,3) of 0.77 (95% CI, 0.36-0.92) for 3 averaged measures. The SEM and MDC were larger for the interrater reliability measures (SEM = 62.79 or 1.57% of the pooled mean; MDC 95  = 174.05).

Conclusions: Quantitative ultrasound SOS measurement at the distal radius showed excellent within-day intrarater and good interrater (when 3 measures were averaged) reliability in community-dwelling postmenopausal women. The SEM and MDC 95 were also low for interrater reliability when a mean of 3 trials was used. This study is the first to demonstrate that this particular QUS device at the radius may be a reliable fracture risk screening tool for postmenopausal women.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
训练有素的评分员对绝经后妇女桡骨远端定量超声波声速的校内和校间信度
背景和目的:在桡骨远端进行的定量超声(QUS)显示出作为评估骨折风险的有效工具的潜力,尤其是在绝经后妇女中,但该工具在这一患者群体中的可靠性尚未见报道。本研究调查了训练有素的评分员在绝经后社区居住妇女的桡骨远端进行 QUS 测量时的日内评分和评分间可靠性:研究从南卡罗来纳州格林维尔地区的老年中心招募了 18 名年龄在 56 岁至 87 岁之间的妇女并征得她们的同意。研究中使用了 QUS 骨声波仪;训练有素的评分员在同一天对每位参与者的非优势桡骨重复进行了 3 次声速 (SOS) 测量。我们计算了类内相关系数(ICC)(3,1 模型表示评分者内部的可靠性,2,3 模型表示评分者之间的可靠性),以确定评分者内部和评分者之间的可靠性。此外,我们还计算了测量标准误差(SEM)和 95% 置信区间(MDC95)的最小可检测变化:结果:两位物理治疗师评分者的日内评分可靠性都很好(ICC(3,1) 在 0.93 到 0.91 之间)。两位评分者的日内评分可靠性测量的 SEM 和 MDC 都很小(SEM = 36.79-38.75 或汇总平均值的 0.92%-0.97%;MDC95 = 101.99-107.40)。使用径向 QUS 测量 SOS 的评分者间可靠性良好,3 次平均测量的 ICC(2,3) 为 0.77(95% CI,0.36-0.92)。在检查者之间的可靠性测量中,SEM和MDC较大(SEM = 62.79,占汇总平均值的1.57%;MDC95 = 174.05):结论:在社区居住的绝经后妇女中,桡骨远端定量超声SOS测量显示出极佳的日内可靠性和较好的测量间可靠性(3次测量取平均值)。当使用 3 次试验的平均值时,SEM 和 MDC95 在检查者间的可靠性也较低。这项研究首次证明,桡骨处的这种特殊 QUS 装置可能是绝经后妇女可靠的骨折风险筛查工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Geriatric Physical Therapy
Journal of Geriatric Physical Therapy GERIATRICS & GERONTOLOGY-REHABILITATION
CiteScore
3.70
自引率
4.20%
发文量
58
审稿时长
>12 weeks
期刊介绍: ​Journal of Geriatric Physical Therapy is the leading source of clinically applicable evidence for achieving optimal health, wellness, mobility, and physical function across the continuum of health status for the aging adult. The mission of the Academy of Geriatric Physical Therapy is building a community that advances the profession of physical therapy to optimize the experience of aging.
期刊最新文献
A Scoping Review of the Predictive Qualities of Walking Speed in Older Adults. Associations of Usual and Fast Gait Speed With Physical Performance and Balance Confidence in Community-Dwelling Older Adults: Implications for Assessment. Simple Mobility Tests Predict Use of Assistive Devices in Older Adults. Step Test Evaluation of Performance on Stairs (STEPS): Assessing Stair Function in Older Adults. The Power of Language: Words to Mend or Fuel Ageism Within Geriatrics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1