Virtual surgical planning and use of a 3D-printed, patient-specific reduction system for minimally invasive plate osteosynthesis of diaphyseal tibial fractures in dogs: A historic case control study.
Logan M Scheuermann, Daniel D Lewis, Matthew D Johnson, Adam H Biedrzycki, Stanley E Kim
{"title":"Virtual surgical planning and use of a 3D-printed, patient-specific reduction system for minimally invasive plate osteosynthesis of diaphyseal tibial fractures in dogs: A historic case control study.","authors":"Logan M Scheuermann, Daniel D Lewis, Matthew D Johnson, Adam H Biedrzycki, Stanley E Kim","doi":"10.1111/vsu.14112","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the efficacy and clinical outcomes of computed tomography (CT)-based virtual surgical planning (VSP) and a three-dimensional (3D)-printed, patient-specific reduction system to conventional indirect reduction techniques for diaphyseal tibial fractures stabilized using minimally invasive plate osteosynthesis (MIPO) in dogs.</p><p><strong>Study design: </strong>A prospective clinical study with a historic control cohort.</p><p><strong>Sample population: </strong>Dogs undergoing MIPO stabilization of diaphyseal tibial fractures using a custom 3D-printed reduction system (3D-MIPO; n = 15) or conventional indirect reduction techniques (c-MIPO; n = 14).</p><p><strong>Methods: </strong>Dogs were prospectively enrolled to the 3D-MIPO group and CT scans were used to design and fabricate a custom 3D-printed reduction system to facilitate MIPO. Medical records were searched to identify dogs for the c-MIPO group. Pre-, intra- and postoperative parameters were compared between groups.</p><p><strong>Results: </strong>The duration from presentation until surgery was 23 h longer in the 3D-MIPO group (p = .002). Fewer intraoperative fluoroscopic images were acquired (p < .001) and mean surgical duration was 34 min shorter in the 3D-MIPO group (p = .014). Median postoperative tibial length, frontal alignment, and sagittal alignment were within 4 mm, 3° and 3°, respectively, of the contralateral tibia in both groups and did not differ between reduction groups (p > .1). Postoperative complications occurred in 27% and 14% of fractures in the 3D-MIPO and c-MIPO groups, respectively.</p><p><strong>Conclusion: </strong>Both reduction methods yielded comparable results. Although the preoperative planning and guide preparation was time consuming, surgery times were shorter and fluoroscopy use was less in the 3D-MIPO group.</p><p><strong>Clinical significance: </strong>VSP and the custom 3D-printed reduction system facilitated efficient MIPO.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":"53 6","pages":"1052-1061"},"PeriodicalIF":1.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.14112","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To compare the efficacy and clinical outcomes of computed tomography (CT)-based virtual surgical planning (VSP) and a three-dimensional (3D)-printed, patient-specific reduction system to conventional indirect reduction techniques for diaphyseal tibial fractures stabilized using minimally invasive plate osteosynthesis (MIPO) in dogs.
Study design: A prospective clinical study with a historic control cohort.
Sample population: Dogs undergoing MIPO stabilization of diaphyseal tibial fractures using a custom 3D-printed reduction system (3D-MIPO; n = 15) or conventional indirect reduction techniques (c-MIPO; n = 14).
Methods: Dogs were prospectively enrolled to the 3D-MIPO group and CT scans were used to design and fabricate a custom 3D-printed reduction system to facilitate MIPO. Medical records were searched to identify dogs for the c-MIPO group. Pre-, intra- and postoperative parameters were compared between groups.
Results: The duration from presentation until surgery was 23 h longer in the 3D-MIPO group (p = .002). Fewer intraoperative fluoroscopic images were acquired (p < .001) and mean surgical duration was 34 min shorter in the 3D-MIPO group (p = .014). Median postoperative tibial length, frontal alignment, and sagittal alignment were within 4 mm, 3° and 3°, respectively, of the contralateral tibia in both groups and did not differ between reduction groups (p > .1). Postoperative complications occurred in 27% and 14% of fractures in the 3D-MIPO and c-MIPO groups, respectively.
Conclusion: Both reduction methods yielded comparable results. Although the preoperative planning and guide preparation was time consuming, surgery times were shorter and fluoroscopy use was less in the 3D-MIPO group.
Clinical significance: VSP and the custom 3D-printed reduction system facilitated efficient MIPO.
期刊介绍:
Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations.
It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.