Optimizing K-means clustering center selection with density-based spatial cluster in radial basis function neural network for load forecasting of smart solar microgrid

IF 1.6 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Electrical Engineering Pub Date : 2024-07-29 DOI:10.1007/s00202-024-02599-y
Thao Nguyen Da, Ming-Yuan Cho, Phuong Nguyen Thanh
{"title":"Optimizing K-means clustering center selection with density-based spatial cluster in radial basis function neural network for load forecasting of smart solar microgrid","authors":"Thao Nguyen Da, Ming-Yuan Cho, Phuong Nguyen Thanh","doi":"10.1007/s00202-024-02599-y","DOIUrl":null,"url":null,"abstract":"<p>Many researchers have investigated estimating and forecasting load power by utilizing many approaches and techniques in neural networks. In this case study, a novel method is proposed to achieve higher accuracy in load-predicting performance in the smart solar microgrid. The K-means cluster is optimized with a density-based spatial cluster and is then utilized to determine the center points in the radial basis function neural network. The proposed method is analyzed and evaluated in the dataset, which is accumulated from the advanced meter infrastructure (AMI) in the smart solar microgrid in 6 months. The proposed methodology is deployed in load power forecasting in various horizons ranging from 10, 20, and 30 min. This optimized technique was inspected and compared against persistence methods, which only apply K-means cluster for center selection in RBF neural network, by using MATLAB simulations. The experimental results proved that the developing enhancement could achieve the maximum improvement of 7.432% <i>R</i>-square, 70.519% mean absolute percentage error (MAPE), and 80.769% root mean squared error (RMSE). The optimized algorithm could effectively eliminate the maximum average of 2.418% of the outer points in the dataset, which decreased the learning time during the modeling process and acquired better convergent velocity and stability compared with the persistent method. Moreover, when combined with enhanced methodology, the 10-min interval data had higher effectiveness and accuracy than the 20-min and 30-min data.</p>","PeriodicalId":50546,"journal":{"name":"Electrical Engineering","volume":"151 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s00202-024-02599-y","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Many researchers have investigated estimating and forecasting load power by utilizing many approaches and techniques in neural networks. In this case study, a novel method is proposed to achieve higher accuracy in load-predicting performance in the smart solar microgrid. The K-means cluster is optimized with a density-based spatial cluster and is then utilized to determine the center points in the radial basis function neural network. The proposed method is analyzed and evaluated in the dataset, which is accumulated from the advanced meter infrastructure (AMI) in the smart solar microgrid in 6 months. The proposed methodology is deployed in load power forecasting in various horizons ranging from 10, 20, and 30 min. This optimized technique was inspected and compared against persistence methods, which only apply K-means cluster for center selection in RBF neural network, by using MATLAB simulations. The experimental results proved that the developing enhancement could achieve the maximum improvement of 7.432% R-square, 70.519% mean absolute percentage error (MAPE), and 80.769% root mean squared error (RMSE). The optimized algorithm could effectively eliminate the maximum average of 2.418% of the outer points in the dataset, which decreased the learning time during the modeling process and acquired better convergent velocity and stability compared with the persistent method. Moreover, when combined with enhanced methodology, the 10-min interval data had higher effectiveness and accuracy than the 20-min and 30-min data.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用径向基函数神经网络中基于密度的空间聚类优化 K-means 聚类中心选择,用于智能太阳能微电网的负荷预测
许多研究人员利用神经网络中的多种方法和技术对负荷功率的估计和预测进行了研究。在本案例研究中,提出了一种新方法,以实现更高精度的智能太阳能微电网负荷预测性能。通过基于密度的空间聚类对 K-means 聚类进行优化,然后利用 K-means 聚类确定径向基函数神经网络的中心点。提出的方法在数据集中进行了分析和评估,数据集是智能太阳能微电网中先进的电表基础设施(AMI)在 6 个月内积累的数据。所提出的方法被部署在 10、20 和 30 分钟等不同范围的负荷功率预测中。通过使用 MATLAB 仿真,对这一优化技术进行了检验,并与仅在 RBF 神经网络中使用 K-means 聚类进行中心选择的持续性方法进行了比较。实验结果证明,开发的增强算法最大程度地提高了 7.432% 的 R-square、70.519% 的平均绝对百分比误差(MAPE)和 80.769% 的均方根误差(RMSE)。优化后的算法能有效消除数据集中最大平均 2.418% 的外围点,减少了建模过程中的学习时间,收敛速度和稳定性均优于传统方法。此外,结合增强方法,10 分钟间隔数据的有效性和准确性均高于 20 分钟和 30 分钟数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Electrical Engineering
Electrical Engineering 工程技术-工程:电子与电气
CiteScore
3.60
自引率
16.70%
发文量
0
审稿时长
>12 weeks
期刊介绍: The journal “Electrical Engineering” following the long tradition of Archiv für Elektrotechnik publishes original papers of archival value in electrical engineering with a strong focus on electric power systems, smart grid approaches to power transmission and distribution, power system planning, operation and control, electricity markets, renewable power generation, microgrids, power electronics, electrical machines and drives, electric vehicles, railway electrification systems and electric transportation infrastructures, energy storage in electric power systems and vehicles, high voltage engineering, electromagnetic transients in power networks, lightning protection, electrical safety, electrical insulation systems, apparatus, devices, and components. Manuscripts describing theoretical, computer application and experimental research results are welcomed. Electrical Engineering - Archiv für Elektrotechnik is published in agreement with Verband der Elektrotechnik Elektronik Informationstechnik eV (VDE).
期刊最新文献
A method for assessing and locating protection measurement loop errors based on an improved similarity algorithm Microgrid energy management with renewable energy using gravitational search algorithm Generation expansion planning incorporating the recuperation of older power plants for economic advantage Robot dynamics-based cable fault diagnosis using stacked transformer encoder layers Rule based coordinated source and demand side energy management of a remote area power supply system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1