{"title":"Early fault detection via combining multilinear PCA with retrospective monitoring using weighted features","authors":"Burak Alakent","doi":"10.1007/s43153-024-00483-7","DOIUrl":null,"url":null,"abstract":"<p>Current multivariate statistical process monitoring is mostly based on data-based models with the principal aim of detecting faults promptly. To increase fault detection performance, various methods, such as novel learners, sliding window-based methods, subspaces based on query point estimation residuals, and feature/component selection methods have been proposed. On the other hand, hierarchical and combined modeling have only been recently considered; furthermore, the online sampled observations, once assessed by the monitoring scheme, are not usually used again for fault detection. In the current study, we show how to obtain valuable information on faults via re-examining the recently sampled points in a conveniently built hierarchical monitoring scheme. The top level consists of a combination of a novel query point estimation method based on multilinear principal component analysis (PCA) and PCA model of the estimation residuals. Upon a warning signal from the upper level, the bottom level is implemented, that consists of retrospective PCA monitoring of the recently sampled observations, scaled with respect to estimation residuals. Implementation of the proposed scheme on a demonstrative process and Tennessee Eastman Plant data exhibits decrease both in fault detection delay and missed detection rate compared to both traditional and the recently proposed methods.</p>","PeriodicalId":9194,"journal":{"name":"Brazilian Journal of Chemical Engineering","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Chemical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s43153-024-00483-7","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Current multivariate statistical process monitoring is mostly based on data-based models with the principal aim of detecting faults promptly. To increase fault detection performance, various methods, such as novel learners, sliding window-based methods, subspaces based on query point estimation residuals, and feature/component selection methods have been proposed. On the other hand, hierarchical and combined modeling have only been recently considered; furthermore, the online sampled observations, once assessed by the monitoring scheme, are not usually used again for fault detection. In the current study, we show how to obtain valuable information on faults via re-examining the recently sampled points in a conveniently built hierarchical monitoring scheme. The top level consists of a combination of a novel query point estimation method based on multilinear principal component analysis (PCA) and PCA model of the estimation residuals. Upon a warning signal from the upper level, the bottom level is implemented, that consists of retrospective PCA monitoring of the recently sampled observations, scaled with respect to estimation residuals. Implementation of the proposed scheme on a demonstrative process and Tennessee Eastman Plant data exhibits decrease both in fault detection delay and missed detection rate compared to both traditional and the recently proposed methods.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用加权特征将多线性 PCA 与回顾性监测相结合,实现早期故障检测
目前的多元统计过程监控大多基于数据模型,主要目的是及时发现故障。为了提高故障检测性能,人们提出了各种方法,如新型学习器、基于滑动窗口的方法、基于查询点估计残差的子空间以及特征/组件选择方法。另一方面,分层建模和组合建模最近才被考虑;此外,在线采样的观测结果一旦经过监控方案的评估,通常不会再次用于故障检测。在当前的研究中,我们展示了如何在一个方便构建的分层监控方案中,通过重新检查最近的采样点来获取有价值的故障信息。顶层由基于多线性主成分分析(PCA)的新型查询点估算方法和估算残差的 PCA 模型组合而成。上层发出警告信号后,下层开始实施,包括对最近采样的观测数据进行追溯 PCA 监测,并根据估计残差进行缩放。与传统方法和最新提出的方法相比,在示范流程和田纳西州伊士曼工厂数据上实施拟议方案可减少故障检测延迟和漏检率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Brazilian Journal of Chemical Engineering
Brazilian Journal of Chemical Engineering 工程技术-工程:化工
CiteScore
2.50
自引率
0.00%
发文量
84
审稿时长
6.8 months
期刊介绍: The Brazilian Journal of Chemical Engineering is a quarterly publication of the Associação Brasileira de Engenharia Química (Brazilian Society of Chemical Engineering - ABEQ) aiming at publishing papers reporting on basic and applied research and innovation in the field of chemical engineering and related areas.
期刊最新文献
C4 hydrocarbons to value-added chemicals over Keggin-type heteropolyacids: structure-properties, reaction parameters, and mechanisms Utilization of blue light-emitting diodes in Ensifer meliloti cultivation for enhanced production of antioxidant biopolymers Correlation of the solubility of isoniazid in some aqueous cosolvent mixtures using different mathematical models Doehlert matrix-based optimization of degradation of Rhodamine B in a swirling flow photolytic reactor operated in recirculation mode Application of DieselB10 formulations with short-chain alcohols in diesel cycle engines: phase equilibrium, physicochemical and thermodynamic properties and power curves
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1