Reliability and Validity of the Martin Vigorimeter for Grip Strength Measurement in Korean Adults.

IF 1.9 2区 医学 Q2 ORTHOPEDICS Clinics in Orthopedic Surgery Pub Date : 2024-08-01 Epub Date: 2024-06-07 DOI:10.4055/cios23383
Jeong Kil Lee, Meesun Jung, Han Byul Lee, Hyung Jin Chung, Seung Hoo Lee
{"title":"Reliability and Validity of the Martin Vigorimeter for Grip Strength Measurement in Korean Adults.","authors":"Jeong Kil Lee, Meesun Jung, Han Byul Lee, Hyung Jin Chung, Seung Hoo Lee","doi":"10.4055/cios23383","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Grip strength is important for fine motor skills, and one of the measurement tools for grip strength is the Martin Vigorimeter (MV) dynamometer. Studies on establishing the reliability and validity of the MV in Koreans are limited. We aimed to establish the reliability and validity of the MV for grip strength measurement in healthy Korean adults by comparing it with the Jamar dynamometer, the standard tool used by the American Society of Hand Therapists.</p><p><strong>Methods: </strong>In total, 99 healthy participants (50 men and 49 women) were enrolled. Grip strength was measured using the Jamar dynamometer and MV. Reliability and validity were assessed using the intraclass correlation coefficient (ICC) and minimal detectable change (MDC). The correlation between the measurements of the instruments was analyzed using Pearson's correlation. The effect of hand anthropometry was evaluated, and the conversion equation between the instruments was calculated.</p><p><strong>Results: </strong>MV showed excellent reliability (ICC > 0.90, <i>p</i> < 0.001) and validity with a high correlation (0.7 ≤ <i>r</i> < 0.9) with the Jamar dynamometer. The MDC was acceptable for detecting minimal clinically important differences (< 19.5%) in both instruments (Jamar: 3.4%-6.7%, MV: 3.8% to 6.3%). The grip strength measured using the MV was independent of hand anthropometry, unlike that using the Jamar dynamometer.</p><p><strong>Conclusions: </strong>This study provides insights into the relationship between the Jamar and MV instruments for measuring grip strength in Koreans. The MV is a viable alternative to the Jamar dynamometer in Koreans, offering not only reproducible and reliable measurements of grip strength but also the advantage of being unaffected by variations in hand anthropometry.</p>","PeriodicalId":47648,"journal":{"name":"Clinics in Orthopedic Surgery","volume":"16 4","pages":"610-619"},"PeriodicalIF":1.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11262940/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics in Orthopedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4055/cios23383","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Grip strength is important for fine motor skills, and one of the measurement tools for grip strength is the Martin Vigorimeter (MV) dynamometer. Studies on establishing the reliability and validity of the MV in Koreans are limited. We aimed to establish the reliability and validity of the MV for grip strength measurement in healthy Korean adults by comparing it with the Jamar dynamometer, the standard tool used by the American Society of Hand Therapists.

Methods: In total, 99 healthy participants (50 men and 49 women) were enrolled. Grip strength was measured using the Jamar dynamometer and MV. Reliability and validity were assessed using the intraclass correlation coefficient (ICC) and minimal detectable change (MDC). The correlation between the measurements of the instruments was analyzed using Pearson's correlation. The effect of hand anthropometry was evaluated, and the conversion equation between the instruments was calculated.

Results: MV showed excellent reliability (ICC > 0.90, p < 0.001) and validity with a high correlation (0.7 ≤ r < 0.9) with the Jamar dynamometer. The MDC was acceptable for detecting minimal clinically important differences (< 19.5%) in both instruments (Jamar: 3.4%-6.7%, MV: 3.8% to 6.3%). The grip strength measured using the MV was independent of hand anthropometry, unlike that using the Jamar dynamometer.

Conclusions: This study provides insights into the relationship between the Jamar and MV instruments for measuring grip strength in Koreans. The MV is a viable alternative to the Jamar dynamometer in Koreans, offering not only reproducible and reliable measurements of grip strength but also the advantage of being unaffected by variations in hand anthropometry.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
马丁握力计测量韩国成年人握力的可靠性和有效性
背景:握力对精细运动技能非常重要,马丁测力计(MV)是测量握力的工具之一。有关在韩国人中建立 MV 的可靠性和有效性的研究很有限。我们的目的是通过将马丁测力计与美国手部治疗师协会使用的标准工具贾马尔测力计进行比较,确定马丁测力计在韩国健康成年人中测量握力的可靠性和有效性:方法:共招募了 99 名健康参与者(50 名男性和 49 名女性)。使用贾马尔测力计和 MV 测量握力。使用类内相关系数(ICC)和最小可检测变化(MDC)评估了可靠性和有效性。仪器测量值之间的相关性使用皮尔逊相关性进行分析。评估了手部人体测量的影响,并计算了仪器之间的转换方程:MV显示出极佳的可靠性(ICC > 0.90,p < 0.001)和有效性,与Jamar测力计的相关性很高(0.7 ≤ r < 0.9)。MDC在检测两种仪器的最小临床重要差异(< 19.5%)方面是可以接受的(Jamar:3.4%-6.7%,MV:3.8%-6.3%)。使用 MV 测得的握力与手部人体测量学无关,这与使用 Jamar 测力计不同:本研究深入探讨了测量韩国人握力的 Jamar 和 MV 仪器之间的关系。在韩国人中,MV 是贾马尔测力计的可行替代品,它不仅能提供可重复的、可靠的握力测量,还具有不受手部人体测量变化影响的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
4.00%
发文量
85
审稿时长
36 weeks
期刊最新文献
Staged Fixation with Respect to Soft Tissue in Tibial Plateau Fractures with Acute Compartment Syndrome: Correlation Analysis of Complications. The Incidence and Risk Factors of Symptomatic Local Recurrence Following Surgical Treatment for Spinal Metastasis with Involvement of All Three Columns: Focusing on the Extent of Tumor Removal. Transcultural Adaptation of the Korean Version of the International Hip Outcome Tool 12. Incidence and Risk Factors of Deep Vein Thrombosis after Foot and Ankle Surgery. Open Reduction and Internal Fixation of Distal Radius Fractures with Complete Intra-articular Involvement and Diaphyseal Extension.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1