{"title":"Effect of Deep Learning Image Reconstruction Algorithms on Radiomic Features of Pulmonary Nodules in Ultra-Low-Dose CT.","authors":"Zhijuan Zheng, Yuying Liang, Zhehao Wu, Qijia Han, Zhu Ai, Kun Ma, Zhiming Xiang","doi":"10.1097/RCT.0000000000001634","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The purpose of this study is to explore the impact of deep learning image reconstruction (DLIR) algorithm on the quantification of radiomic features in ultra-low-dose computed tomography (ULD-CT) compared with adaptive statistical iterative reconstruction-Veo (ASIR-V).</p><p><strong>Methods: </strong>One hundred eighty-three patients with pulmonary nodules underwent standard-dose computed tomography (SDCT) (4.30 ± 0.36 mSv) and ULD-CT (UL-A, 0.57 ± 0.09 mSv or UL-B, 0.33 ± 0.04 mSv). SDCT was the reference standard using (ASIR-V) at 50% strength (50%ASIR-V). ULD-CT was reconstructed with 50%ASIR-V, DLIR at medium and high strength (DLIR-M, DLIR-H). Radiomics analysis extracted 102 features, and the intraclass correlation coefficient (ICC) quantified reproducibility between ULD-CT and SDCT reconstructed by 50%ASIR-V, DLIR-M, and DLIR-H for each feature.</p><p><strong>Results: </strong>Among 102 radiomic features, the percentages of reproducibility of 50%ASIR-V, DLIR-M, and DLIR-H were 48.04% (49/102), 49.02% (50/102), and 52.94% (54/102), respectively. Shape and first order features demonstrated high reproducibility across different reconstruction algorithms and radiation doses, with mean ICC values exceeding 0.75. In texture features, DLIR-M and DLIR-H showed improved mean ICC values for pure ground glass nodules (pGGNs) from 0.69 ± 0.23 to 0.75 ± 0.18 and 0.81 ± 0.12, respectively, compared with 50%ASIR-V. Similarly, the mean ICC values for solid nodules (SNs) increased from 0.60 ± 0.19 to 0.66 ± 0.14 and 0.69 ± 0.13, respectively. Additionally, the mean ICC values of texture features for pGGNs and SNs in both ULD-CT groups decreased with reduced radiation dose.</p><p><strong>Conclusions: </strong>DLIR can improve the reproducibility of radiomic features at ultra-low doses compared with ASIR-V. In addition, pGGNs showed better reproducibility at ultra-low doses than SNs.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001634","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The purpose of this study is to explore the impact of deep learning image reconstruction (DLIR) algorithm on the quantification of radiomic features in ultra-low-dose computed tomography (ULD-CT) compared with adaptive statistical iterative reconstruction-Veo (ASIR-V).
Methods: One hundred eighty-three patients with pulmonary nodules underwent standard-dose computed tomography (SDCT) (4.30 ± 0.36 mSv) and ULD-CT (UL-A, 0.57 ± 0.09 mSv or UL-B, 0.33 ± 0.04 mSv). SDCT was the reference standard using (ASIR-V) at 50% strength (50%ASIR-V). ULD-CT was reconstructed with 50%ASIR-V, DLIR at medium and high strength (DLIR-M, DLIR-H). Radiomics analysis extracted 102 features, and the intraclass correlation coefficient (ICC) quantified reproducibility between ULD-CT and SDCT reconstructed by 50%ASIR-V, DLIR-M, and DLIR-H for each feature.
Results: Among 102 radiomic features, the percentages of reproducibility of 50%ASIR-V, DLIR-M, and DLIR-H were 48.04% (49/102), 49.02% (50/102), and 52.94% (54/102), respectively. Shape and first order features demonstrated high reproducibility across different reconstruction algorithms and radiation doses, with mean ICC values exceeding 0.75. In texture features, DLIR-M and DLIR-H showed improved mean ICC values for pure ground glass nodules (pGGNs) from 0.69 ± 0.23 to 0.75 ± 0.18 and 0.81 ± 0.12, respectively, compared with 50%ASIR-V. Similarly, the mean ICC values for solid nodules (SNs) increased from 0.60 ± 0.19 to 0.66 ± 0.14 and 0.69 ± 0.13, respectively. Additionally, the mean ICC values of texture features for pGGNs and SNs in both ULD-CT groups decreased with reduced radiation dose.
Conclusions: DLIR can improve the reproducibility of radiomic features at ultra-low doses compared with ASIR-V. In addition, pGGNs showed better reproducibility at ultra-low doses than SNs.
期刊介绍:
The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).