Night-time blood pressure dipping, but not 24-h blood pressure level, is linked to increased 24-h ocular volume slope.

IF 1.2 4区 医学 Q3 OPHTHALMOLOGY Arquivos brasileiros de oftalmologia Pub Date : 2024-08-02 eCollection Date: 2024-01-01 DOI:10.5935/0004-2749.2022-0236
Janusz Skrzypecki, F M Szymański, J Przybek-Skrzypecka, Justyna Izdebska, A Ryś-Czaporowska, K J Filipiak, Jacek P Szaflik
{"title":"Night-time blood pressure dipping, but not 24-h blood pressure level, is linked to increased 24-h ocular volume slope.","authors":"Janusz Skrzypecki, F M Szymański, J Przybek-Skrzypecka, Justyna Izdebska, A Ryś-Czaporowska, K J Filipiak, Jacek P Szaflik","doi":"10.5935/0004-2749.2022-0236","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study investigated the relationship between blood pressure and intraocular pressure in treatmentnaive, non-glaucoma patients with different blood pressure statuses, focusing on the 24-h ocular volume and nocturnal blood pressure decline.</p><p><strong>Methods: </strong>Treatment-naive, non-glaucoma patients undergoing hypertension evaluation were enrolled as study participants. Simultaneous 24-h ambulatory blood pressure measurement and 24-h ocular volume recording with a contact lens sensor. We also compared ocular volume curve parameters between normotensive and hypertensive patients, as well as between those with and without nocturnal blood pressure decline.</p><p><strong>Results: </strong>A total of 21 patients, including 7 normotensive and 14 treatment-naive hypertensive individuals, were included in the study. of them, 11 were dippers and 10 were non-dippers. No significant difference in the 24-h ocular volume slope was observed between the hypertensive and normotensive patients (p=0.284). However, dippers had a significantly higher 24-h ocular volume slope (p=0.004) and nocturnal contact lens sensor output (p=0.041) than non-dippers.</p><p><strong>Conclusion: </strong>Nocturnal blood pressure decline, rather than the blood pressure level, is associated with the increased 24-h ocular volume slope and nocturnal ocular volume. Further studies are required to determine whether the acceleration of glaucoma progression in dippers is primarily due to low blood pressure, high intraocular pressure, or a combination of both.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"88 1","pages":"e20220236"},"PeriodicalIF":1.2000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12585022/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arquivos brasileiros de oftalmologia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5935/0004-2749.2022-0236","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study investigated the relationship between blood pressure and intraocular pressure in treatmentnaive, non-glaucoma patients with different blood pressure statuses, focusing on the 24-h ocular volume and nocturnal blood pressure decline.

Methods: Treatment-naive, non-glaucoma patients undergoing hypertension evaluation were enrolled as study participants. Simultaneous 24-h ambulatory blood pressure measurement and 24-h ocular volume recording with a contact lens sensor. We also compared ocular volume curve parameters between normotensive and hypertensive patients, as well as between those with and without nocturnal blood pressure decline.

Results: A total of 21 patients, including 7 normotensive and 14 treatment-naive hypertensive individuals, were included in the study. of them, 11 were dippers and 10 were non-dippers. No significant difference in the 24-h ocular volume slope was observed between the hypertensive and normotensive patients (p=0.284). However, dippers had a significantly higher 24-h ocular volume slope (p=0.004) and nocturnal contact lens sensor output (p=0.041) than non-dippers.

Conclusion: Nocturnal blood pressure decline, rather than the blood pressure level, is associated with the increased 24-h ocular volume slope and nocturnal ocular volume. Further studies are required to determine whether the acceleration of glaucoma progression in dippers is primarily due to low blood pressure, high intraocular pressure, or a combination of both.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
夜间血压下降(而非 24 小时血压水平)与 24 小时眼容量斜率增加有关。
目的:本研究调查了不同血压状态的非青光眼患者的血压与眼压之间的关系,重点是 24 小时眼容量和夜间血压下降情况:研究对象为接受高血压评估的非青光眼患者。使用隐形眼镜传感器同时测量 24 小时动态血压和记录 24 小时眼容量。我们还比较了正常血压患者和高血压患者的眼容量曲线参数,以及夜间血压下降患者和非夜间血压下降患者的眼容量曲线参数:研究共纳入 21 名患者,包括 7 名血压正常者和 14 名未接受治疗的高血压患者。高血压患者和正常血压患者的 24 小时眼容量斜率无明显差异(P=0.284)。然而,与非嗜尿者相比,嗜尿者的 24 小时眼容量斜率(p=0.004)和夜间隐形眼镜传感器输出量(p=0.041)明显更高:结论:夜间血压下降而非血压水平与 24 小时眼容量斜率和夜间眼容量增加有关。还需要进一步研究,以确定糖尿病患者青光眼进展加速的主要原因是低血压、高眼压,还是两者的共同作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.60
自引率
0.00%
发文量
200
审稿时长
6-12 weeks
期刊介绍: The ABO-ARQUIVOS BRASILEIROS DE OFTALMOLOGIA (ABO, ISSN 0004-2749 - print and ISSN 1678-2925 - (ABO, ISSN 0004-2749 - print and ISSN 1678-2925 - electronic version), the official bimonthly publication of the Brazilian Council of Ophthalmology (CBO), aims to disseminate scientific studies in Ophthalmology, Visual Science and Health public, by promoting research, improvement and updating of professionals related to the field.
期刊最新文献
Kahook Dual-Blade goniotomy combined with phacoemulsification in primary open-angle glaucoma patients: long-term results. Impact of mydriasis on image gradability and automated diabetic retinopathy screening with a handheld camera. A real-world setting evaluation. Management of glaucoma during pregnancy and lactation: clinical considerations and therapeutic strategies. Surgical procedures in glaucoma: A preferred practice pattern report by the Latin American Glaucoma Society. Custom slow-coagulation transscleral cyclophotocoagulation: a novel cyclophotocoagulation technique for refractory glaucoma patients in a safety-net eye hospital in Mexico.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1