Does the Angulation of the Screws in the Zero-P Implant Affect the Clinical and Radiological Outcomes of Patients?

IF 1.8 2区 医学 Q2 ORTHOPEDICS Orthopaedic Surgery Pub Date : 2024-11-01 Epub Date: 2024-08-06 DOI:10.1111/os.14182
Cheng-Yi Huang, Xia-Qing Sheng, Ting-Kui Wu, Bei-Yu Wang, Ding-Ke Wen, Li He, Hao Liu
{"title":"Does the Angulation of the Screws in the Zero-P Implant Affect the Clinical and Radiological Outcomes of Patients?","authors":"Cheng-Yi Huang, Xia-Qing Sheng, Ting-Kui Wu, Bei-Yu Wang, Ding-Ke Wen, Li He, Hao Liu","doi":"10.1111/os.14182","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>When implanting the Zero-P device, the screws of Zero-P form a bone wedge with a 40 ± 5° cranial and caudal angle (CCA). However, no study has been performed in the optimal CCA of the Zero-P implant. To investigate whether the cranial/caudal angles (CCA) of the screws affect the clinical and radiological outcomes in patients undergoing ACDF with the Zero-P implant.</p><p><strong>Methods: </strong>From January 2016 to December 2023, we retrospectively analyzed 186 patients who underwent 1-level ACDF with the Zero-P device. The patients were divided into four groups: group A (cranial angle ≤40°, caudal angle ≤40°); group B (cranial angle ≤40°, caudal angle >40°); group C (cranial angle >40°, caudal angle ≤40°); and group D (cranial angle >40°, caudal angle >40°). The clinical outcomes, including Japanese Orthopaedic Association (JOA), neck disability index (NDI), and visual analogue scale (VAS) scores, the radiological parameters, including cervical lordosis (CL), cervical lordosis of operated segments (OPCL), intervertebral space height (ISH) and fusion rate (FR), and the complications, were evaluated and compared. Parametric tests, non-parametric tests, and chi-square tests were conducted to analyze the data.</p><p><strong>Results: </strong>The OPCL of group A was significantly less than that of the other groups at the final follow-up (p < 0.05). The ISH of group D was significantly less than that of group A at the final follow-up (p < 0.05). The subsidence rate of group A was significantly less than that of group D at the final follow-up (p < 0.05). At the final follow-up, the upper adjacent-level degeneration (ASD) of group D was significantly less severe than that of groups A and B (p < 0.05). The clinical outcomes do not differ among groups (p > 0.05).</p><p><strong>Conclusion: </strong>A larger CCA of the screws (cranial angle >40°, caudal angle >40°) was better for maintaining OPCL and reducing the incidence of ASD. A smaller CCA of the screws (cranial angle ≤40°, caudal angle ≤40°) was better for maintaining ISH and reducing the rate of subsidence.</p>","PeriodicalId":19566,"journal":{"name":"Orthopaedic Surgery","volume":" ","pages":"2699-2707"},"PeriodicalIF":1.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11541112/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.14182","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: When implanting the Zero-P device, the screws of Zero-P form a bone wedge with a 40 ± 5° cranial and caudal angle (CCA). However, no study has been performed in the optimal CCA of the Zero-P implant. To investigate whether the cranial/caudal angles (CCA) of the screws affect the clinical and radiological outcomes in patients undergoing ACDF with the Zero-P implant.

Methods: From January 2016 to December 2023, we retrospectively analyzed 186 patients who underwent 1-level ACDF with the Zero-P device. The patients were divided into four groups: group A (cranial angle ≤40°, caudal angle ≤40°); group B (cranial angle ≤40°, caudal angle >40°); group C (cranial angle >40°, caudal angle ≤40°); and group D (cranial angle >40°, caudal angle >40°). The clinical outcomes, including Japanese Orthopaedic Association (JOA), neck disability index (NDI), and visual analogue scale (VAS) scores, the radiological parameters, including cervical lordosis (CL), cervical lordosis of operated segments (OPCL), intervertebral space height (ISH) and fusion rate (FR), and the complications, were evaluated and compared. Parametric tests, non-parametric tests, and chi-square tests were conducted to analyze the data.

Results: The OPCL of group A was significantly less than that of the other groups at the final follow-up (p < 0.05). The ISH of group D was significantly less than that of group A at the final follow-up (p < 0.05). The subsidence rate of group A was significantly less than that of group D at the final follow-up (p < 0.05). At the final follow-up, the upper adjacent-level degeneration (ASD) of group D was significantly less severe than that of groups A and B (p < 0.05). The clinical outcomes do not differ among groups (p > 0.05).

Conclusion: A larger CCA of the screws (cranial angle >40°, caudal angle >40°) was better for maintaining OPCL and reducing the incidence of ASD. A smaller CCA of the screws (cranial angle ≤40°, caudal angle ≤40°) was better for maintaining ISH and reducing the rate of subsidence.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
零 P 种植体中螺钉的角度是否会影响患者的临床和放射结果?
目的:在植入 Zero-P 装置时,Zero-P 的螺钉会形成一个 40 ± 5° 头尾角 (CCA) 的骨楔。然而,目前还没有关于 Zero-P 植入体最佳 CCA 的研究。目的:研究螺钉的头颅/尾椎角度(CCA)是否会影响使用Zero-P种植体进行ACDF的患者的临床和放射学结果:从2016年1月至2023年12月,我们回顾性分析了186例使用Zero-P装置接受1级ACDF的患者。患者分为四组:A组(颅角≤40°,尾角≤40°);B组(颅角≤40°,尾角>40°);C组(颅角>40°,尾角≤40°);D组(颅角>40°,尾角>40°)。对包括日本骨科协会(JOA)、颈部残疾指数(NDI)和视觉模拟量表(VAS)评分在内的临床结果、包括颈椎前凸(CL)、手术节段颈椎前凸(OPCL)、椎间隙高度(ISH)和融合率(FR)在内的放射学参数以及并发症进行了评估和比较。对数据进行了参数检验、非参数检验和卡方检验:结果:最终随访时,A 组的 OPCL 明显低于其他组(P 0.05):结论:螺钉的CCA越大(颅角>40°,尾角>40°),越有利于维持OPCL和降低ASD的发生率。较小的螺钉CCA(颅角≤40°,尾角≤40°)更有利于维持ISH和降低下沉率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Orthopaedic Surgery
Orthopaedic Surgery ORTHOPEDICS-
CiteScore
3.40
自引率
14.30%
发文量
374
审稿时长
20 weeks
期刊介绍: Orthopaedic Surgery (OS) is the official journal of the Chinese Orthopaedic Association, focusing on all aspects of orthopaedic technique and surgery. The journal publishes peer-reviewed articles in the following categories: Original Articles, Clinical Articles, Review Articles, Guidelines, Editorials, Commentaries, Surgical Techniques, Case Reports and Meeting Reports.
期刊最新文献
Observation of the Clinical Efficacy of Self-Modified Skin-Stretching Device in the Treatment of Soft-Tissue Defects of the Heel: A Retrospective Single-Arm Cohort Study. How Accurately Does Bone Mineral Density Predict Bone Strength? A Clinical Observational Study of Osteoporosis Vertebral Compression Fractures in Postmenopausal Women. Comparison of Therapeutic Effects of Different Rehabilitation Methods on Patients Undergoing Total Knee Arthroplasty: A Network Meta-Analysis of Randomized Controlled Trials. Pear-Shaped Disc as a Risk Factor for Postoperative Sclerotic Modic Changes After Transforaminal Lumbar Interbody Fusion. Research Progress on the Posterior Midline Lumbar Spinous Process-Splitting Approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1