Feasibility of Assessment of Habitual Salt Intake Using a 24-h Urinary Salt Excretion Self-Measuring Device.

IF 3.2 3区 医学 Q2 ENDOCRINOLOGY & METABOLISM Annals of Nutrition and Metabolism Pub Date : 2024-08-09 DOI:10.1159/000540797
Nozomi Morikawa, Kotaro Yamasue, Osamu Tochikubo
{"title":"Feasibility of Assessment of Habitual Salt Intake Using a 24-h Urinary Salt Excretion Self-Measuring Device.","authors":"Nozomi Morikawa, Kotaro Yamasue, Osamu Tochikubo","doi":"10.1159/000540797","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>To assess habitual salt intake, tools are needed to measure 24-h urinary salt excretion repeatedly. We developed and validated a new portable salt monitor, which measures salt excreted per urination and sums the values to provide an accurate estimate of urinary salt excretion over 24 h.</p><p><strong>Methods: </strong>A previously developed salt monitor was improved with respect to the capacity, volume sensors, and equation for urinary sodium chloride concentration estimation. In 20 healthy Japanese female volunteers, 24-h urinary salt excretion was measured using the salt monitor and a conventional 24-h urine collection method on eight nonconsecutive days.</p><p><strong>Results: </strong>In a total of 157 days, there were no fixed or proportional errors between the methods. The mean salt intake over 8 days was 8.5 ± 2.0 g/day for the 24-h urine collection and 8.3 ± 2.3 g/day for the salt monitor, showing a strong correlation (r = 0.912, p &lt; 0.001). At a cut-off value of 6 g, the salt monitor was able to completely classify individuals by habitual salt intake.</p><p><strong>Conclusion: </strong>The validity of the new salt monitor was confirmed. The device can be considered an alternative to the traditional 24-h urine collection for repeated surveys and self-management of daily salt intake.</p>","PeriodicalId":8269,"journal":{"name":"Annals of Nutrition and Metabolism","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Nutrition and Metabolism","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000540797","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: To assess habitual salt intake, tools are needed to measure 24-h urinary salt excretion repeatedly. We developed and validated a new portable salt monitor, which measures salt excreted per urination and sums the values to provide an accurate estimate of urinary salt excretion over 24 h.

Methods: A previously developed salt monitor was improved with respect to the capacity, volume sensors, and equation for urinary sodium chloride concentration estimation. In 20 healthy Japanese female volunteers, 24-h urinary salt excretion was measured using the salt monitor and a conventional 24-h urine collection method on eight nonconsecutive days.

Results: In a total of 157 days, there were no fixed or proportional errors between the methods. The mean salt intake over 8 days was 8.5 ± 2.0 g/day for the 24-h urine collection and 8.3 ± 2.3 g/day for the salt monitor, showing a strong correlation (r = 0.912, p < 0.001). At a cut-off value of 6 g, the salt monitor was able to completely classify individuals by habitual salt intake.

Conclusion: The validity of the new salt monitor was confirmed. The device can be considered an alternative to the traditional 24-h urine collection for repeated surveys and self-management of daily salt intake.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用 24 小时尿盐排泄自测装置评估习惯性盐摄入量的可行性。
简介:要评估习惯性盐摄入量,需要有工具来反复测量 24 小时尿盐排泄量。我们开发并验证了一种新型便携式盐分监测仪,该仪器可测量每次排尿排出的盐分,并将数值相加,以准确估计 24 小时内的尿盐排泄量:方法:我们对之前开发的盐分监测仪的容量、体积传感器和尿液氯化钠浓度估算公式进行了改进。在 20 名健康的日本女性志愿者中,使用盐分监测仪和传统的 24 小时尿液收集方法,在非连续的 8 天中测量了 24 小时尿盐排泄量:结果:在总共 157 天的测量中,两种方法之间没有固定误差或比例误差。8 天内 24 小时尿液采集法的平均盐摄入量为 8.5 ± 2.0 克/天,而盐分监测仪的平均盐摄入量为 8.3 ± 2.3 克/天,两者显示出很强的相关性(r = 0.912,p < 0.001)。在截断值为 6 克时,盐分监测仪能够完全按照习惯性盐分摄入量对个人进行分类:新型盐分监测仪的有效性得到了证实。讨论/结论:新型盐分监测仪的有效性得到了证实。该仪器可被视为传统的 24 小时尿液收集方法的替代品,用于重复调查和每日盐分摄入量的自我管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of Nutrition and Metabolism
Annals of Nutrition and Metabolism 医学-内分泌学与代谢
CiteScore
6.50
自引率
0.00%
发文量
55
审稿时长
6-12 weeks
期刊介绍: ''Annals of Nutrition and Metabolism'' is a leading international peer-reviewed journal for sharing information on human nutrition, metabolism and related fields, covering the broad and multidisciplinary nature of science in nutrition and metabolism. As the official journal of both the International Union of Nutritional Sciences (IUNS) and the Federation of European Nutrition Societies (FENS), the journal has a high visibility among both researchers and users of research outputs, including policy makers, across Europe and around the world.
期刊最新文献
Prevalence of Undernutrition and Its Contributing Factors Among Cancer Patients in Africa - A Systematic Review and Meta-Analysis of Observational Studies. An Update on the Diagnosis and Management of Faltering Growth and Catch-Up Growth in Young Children. Seasonal differences of 25-hydroxyvitamin D concentrations in children and adolescents from Mexico City and Metropolitan Area. Stored Energy and Recovery: A Key Factor in Post-stroke Sarcopenia Management. The Importance of Assessing Growth in Infants and Young Children.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1