Reducing electromagnetic interference in MR thermometry: A comparison of setup configurations for MR-guided microwave ablations.

Simon Schröer, Daniel Düx, Josef Joaquin Löning Caballero, Julian Glandorf, Thomas Gerlach, Dominik Horstmann, Othmar Belker, Moritz Gutt, Frank Wacker, Oliver Speck, Bennet Hensen, Marcel Gutberlet
{"title":"Reducing electromagnetic interference in MR thermometry: A comparison of setup configurations for MR-guided microwave ablations.","authors":"Simon Schröer, Daniel Düx, Josef Joaquin Löning Caballero, Julian Glandorf, Thomas Gerlach, Dominik Horstmann, Othmar Belker, Moritz Gutt, Frank Wacker, Oliver Speck, Bennet Hensen, Marcel Gutberlet","doi":"10.1016/j.zemedi.2024.07.004","DOIUrl":null,"url":null,"abstract":"<p><p>Magnetic Resonance (MR) thermometry is used for the monitoring of MR-guided microwave ablations (MWA), and for the intraoperative evaluation of ablation regions. Nevertheless, the accuracy of temperature mapping may be compromised by electromagnetic interference emanating from the microwave (MW) generator. This study evaluated different setups for improving magnetic resonance imaging (MRI) during MWA with a modified MW generator. MWA was performed in 15 gel phantoms comparing three setups: The MW generator was placed outside the MR scanner room, either connected to the MW applicator using a penetration panel with a radiofrequency (RF) filter and a 7 m coaxial cable (Setup 1), or through a waveguide using a 5 m coaxial cable (Setup 2). Setup 3 employed the MW generator within the MR scan room, connected by a 5 m coaxial cable. The coaxial cables in setups 2 and 3 were modified with custom shielding to reduce interference. The setups during ablation (active setup) were compared to a reference setup without the presence of the MW system. Thermometry and thermal dose maps (CEM43 model) were compared for the three configurations. Primary endpoints for assessment were signal-to-noise ratio (SNR), temperature precision, Sørensen-Dice-Coefficient (DSC), and RF-noise spectra. Setup 3 showed highly significant electromagnetic interference during ablation with a SNR decrease by -60.4%±13.5% (p<0.001) compared to reference imaging. For setup 1 and setup 2 no significant decrease in SNR was measured with differences of -2.9%±9.8% (p=0.6) and -1.5%±12.8% (p=0.8), respectively. SNR differences were significant between active setups 1 and 3 with -51.2%±16.1% (p<0.001) and between active setups 2 and 3 with -59.0%±15.5% (p<0.001) but not significant between active setups 1 and 2 with 19.0%±13.7% (p=0.09). Furthermore, no significant differences were seen in temperature precision or DSCs between all setups, ranging from 0.33 °C ± 0.04 °C (Setup 1) to 0.38 °C ± 0.06 °C (Setup 3) (p=0.6) and from 87.0%±1.6% (Setup 3) to 88.1%±1.6% (Setup 2) (p=0.58), respectively. Both setups (1 and 2) with the MW generator outside the MR scanner room were beneficial to reduce electromagnetic interference during MWA. Moreover, provided that a shielded cable is utilized in setups 2 and 3, all configurations displayed negligible differences in temperature precision and DSCs, indicating that the location of the MW generator does not significantly impact the accuracy of thermometry during MWA.</p>","PeriodicalId":101315,"journal":{"name":"Zeitschrift fur medizinische Physik","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur medizinische Physik","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.zemedi.2024.07.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Magnetic Resonance (MR) thermometry is used for the monitoring of MR-guided microwave ablations (MWA), and for the intraoperative evaluation of ablation regions. Nevertheless, the accuracy of temperature mapping may be compromised by electromagnetic interference emanating from the microwave (MW) generator. This study evaluated different setups for improving magnetic resonance imaging (MRI) during MWA with a modified MW generator. MWA was performed in 15 gel phantoms comparing three setups: The MW generator was placed outside the MR scanner room, either connected to the MW applicator using a penetration panel with a radiofrequency (RF) filter and a 7 m coaxial cable (Setup 1), or through a waveguide using a 5 m coaxial cable (Setup 2). Setup 3 employed the MW generator within the MR scan room, connected by a 5 m coaxial cable. The coaxial cables in setups 2 and 3 were modified with custom shielding to reduce interference. The setups during ablation (active setup) were compared to a reference setup without the presence of the MW system. Thermometry and thermal dose maps (CEM43 model) were compared for the three configurations. Primary endpoints for assessment were signal-to-noise ratio (SNR), temperature precision, Sørensen-Dice-Coefficient (DSC), and RF-noise spectra. Setup 3 showed highly significant electromagnetic interference during ablation with a SNR decrease by -60.4%±13.5% (p<0.001) compared to reference imaging. For setup 1 and setup 2 no significant decrease in SNR was measured with differences of -2.9%±9.8% (p=0.6) and -1.5%±12.8% (p=0.8), respectively. SNR differences were significant between active setups 1 and 3 with -51.2%±16.1% (p<0.001) and between active setups 2 and 3 with -59.0%±15.5% (p<0.001) but not significant between active setups 1 and 2 with 19.0%±13.7% (p=0.09). Furthermore, no significant differences were seen in temperature precision or DSCs between all setups, ranging from 0.33 °C ± 0.04 °C (Setup 1) to 0.38 °C ± 0.06 °C (Setup 3) (p=0.6) and from 87.0%±1.6% (Setup 3) to 88.1%±1.6% (Setup 2) (p=0.58), respectively. Both setups (1 and 2) with the MW generator outside the MR scanner room were beneficial to reduce electromagnetic interference during MWA. Moreover, provided that a shielded cable is utilized in setups 2 and 3, all configurations displayed negligible differences in temperature precision and DSCs, indicating that the location of the MW generator does not significantly impact the accuracy of thermometry during MWA.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
减少磁共振测温中的电磁干扰:核磁共振引导下微波消融的设置配置比较。
磁共振(MR)测温技术用于监测磁共振引导下的微波消融术(MWA),以及术中对消融区域进行评估。然而,微波(MW)发生器产生的电磁干扰可能会影响温度测绘的准确性。本研究评估了在使用改进型微波发生器进行 MWA 期间改进磁共振成像(MRI)的不同设置。在 15 个凝胶模型中进行了 MWA,对三种设置进行了比较:磁共振波发生器放置在磁共振扫描室外,使用带有射频(RF)滤波器和 7 米同轴电缆的穿透板连接到磁共振波应用器(设置 1),或使用 5 米同轴电缆通过波导管连接(设置 2)。设置 3 使用磁共振扫描室内的 MW 发生器,通过 5 米长的同轴电缆连接。设置 2 和设置 3 中的同轴电缆经过定制屏蔽处理,以减少干扰。将消融过程中的设置(主动设置)与不使用 MW 系统的参考设置进行了比较。对三种配置的热测量和热剂量图(CEM43 模型)进行了比较。评估的主要终点是信噪比 (SNR)、温度精度、索伦森-迪斯系数 (DSC) 和射频噪声频谱。设置 3 在消融过程中显示出非常明显的电磁干扰,信噪比降低了 -60.4%±13.5% (p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of an MR-only radiotherapy treatment planning workflow using a commercial synthetic CT generator for brain and head & neck tumor patients. Impact of the corneal epithelium on the corneal power using 3D raytracing with OCT data. A noise-robust post-processing pipeline for accelerated phase-cycled 23Na Multi-Quantum Coherences MRI. Imaging dose and image quality of kilovoltage imaging implemented on a helical tomotherapy unit. Ultra-high-resolution brain MRI at 0.55T: bSTAR and its application to magnetization transfer ratio imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1