René Nolio Santa Cruz, Hugo Vaz Sampaio, Carlos Becker Westphall, Maximiliano Dutra de Camargo, Daniela Couto Carvalho Barra
{"title":"Intensive care unit nursing workload estimation in smart hospitals","authors":"René Nolio Santa Cruz, Hugo Vaz Sampaio, Carlos Becker Westphall, Maximiliano Dutra de Camargo, Daniela Couto Carvalho Barra","doi":"10.1108/jhom-01-2024-0019","DOIUrl":null,"url":null,"abstract":"PurposeThe objectives of the proposed model are: aiding nursing staff in documentation tasks, which can be onerous and stressful; and helping management by offering an estimate of the nursing workload, which can be considered for administrative purposes, such as staff scheduling.Design/methodology/approachAn exploratory-descriptive study was conducted in order to identify, investigate, and describe the problem of documenting nursing activities and workload estimation in an intensive care unit. Technological solutions were explored, and models were proposed to address these issues.FindingsCross-dataset experiments were performed, and the model was able to offer an adequate estimate of the nursing workload. The results suggest that continuous retraining is essential for maintaining high accuracy. While the proposed model was considered in the context of an adult ICU, it can be adapted to other contexts, such as elderly care.Research limitations/implicationsWhile the proposed solution seems promising, further research is required, such as deploying this system in an ICU and facing challenges in the areas of computer security, medical ethics, and patient data privacy. More patients’ variables could also be collected to improve the workload estimates.Originality/valueNursing workload assessment is critical to improve the cost-benefit ratio in health care, offer high-quality patient care, and reduce unnecessary expenses, and this process is usually manual. An automated device can automatically document the amount of time spent in patient care activities in a more transparent, efficient, and accurate manner, freeing staff for more urgent activities and keeping management better informed about day-to-day nursing operations.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"9 31","pages":""},"PeriodicalIF":17.7000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1108/jhom-01-2024-0019","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
PurposeThe objectives of the proposed model are: aiding nursing staff in documentation tasks, which can be onerous and stressful; and helping management by offering an estimate of the nursing workload, which can be considered for administrative purposes, such as staff scheduling.Design/methodology/approachAn exploratory-descriptive study was conducted in order to identify, investigate, and describe the problem of documenting nursing activities and workload estimation in an intensive care unit. Technological solutions were explored, and models were proposed to address these issues.FindingsCross-dataset experiments were performed, and the model was able to offer an adequate estimate of the nursing workload. The results suggest that continuous retraining is essential for maintaining high accuracy. While the proposed model was considered in the context of an adult ICU, it can be adapted to other contexts, such as elderly care.Research limitations/implicationsWhile the proposed solution seems promising, further research is required, such as deploying this system in an ICU and facing challenges in the areas of computer security, medical ethics, and patient data privacy. More patients’ variables could also be collected to improve the workload estimates.Originality/valueNursing workload assessment is critical to improve the cost-benefit ratio in health care, offer high-quality patient care, and reduce unnecessary expenses, and this process is usually manual. An automated device can automatically document the amount of time spent in patient care activities in a more transparent, efficient, and accurate manner, freeing staff for more urgent activities and keeping management better informed about day-to-day nursing operations.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.