Intense Noxious Stimulus during an Adequate Depth of General Anesthesia Produces a Transient Burst Suppression Pattern in a Density Spectral Array

Pub Date : 2024-08-08 DOI:10.1055/s-0044-1787977
R. Mariappan, James T. Magar
{"title":"Intense Noxious Stimulus during an Adequate Depth of General Anesthesia Produces a Transient Burst Suppression Pattern in a Density Spectral Array","authors":"R. Mariappan, James T. Magar","doi":"10.1055/s-0044-1787977","DOIUrl":null,"url":null,"abstract":"There has been renewed interest in utilizing electroencephalogram (EEG)/processed EEG to assess the response to noxious stimuli under general anesthesia (GA). We are submitting multiple observations that explore the intriguing phenomenon of the transient burst suppression pattern (BSP) in the density spectral array (DSA) of the SedLine Masimo during intense noxious stimulation under GA. Three patients underwent spine surgery under sevoflurane/total intravenous anesthesia with adequate depth. Sudden transient BSP was noted on the DSA during an intense noxious stimulus. Traditionally, BSP on the processed EEG/DSA under GA in a hemodynamically stable patient indicates excessive hypnosis. It is usually treated by reducing the dose of a hypnotic agent. Decreasing the depth of anesthesia (DOA) in the presence of intense pain can have adverse consequences, especially in high-risk patients. Awareness of processed EEG/DSA changes associated with intense noxious stimuli, helps the anesthesiologist to titrate analgesia without altering DOA.","PeriodicalId":0,"journal":{"name":"","volume":"2 10","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1787977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

There has been renewed interest in utilizing electroencephalogram (EEG)/processed EEG to assess the response to noxious stimuli under general anesthesia (GA). We are submitting multiple observations that explore the intriguing phenomenon of the transient burst suppression pattern (BSP) in the density spectral array (DSA) of the SedLine Masimo during intense noxious stimulation under GA. Three patients underwent spine surgery under sevoflurane/total intravenous anesthesia with adequate depth. Sudden transient BSP was noted on the DSA during an intense noxious stimulus. Traditionally, BSP on the processed EEG/DSA under GA in a hemodynamically stable patient indicates excessive hypnosis. It is usually treated by reducing the dose of a hypnotic agent. Decreasing the depth of anesthesia (DOA) in the presence of intense pain can have adverse consequences, especially in high-risk patients. Awareness of processed EEG/DSA changes associated with intense noxious stimuli, helps the anesthesiologist to titrate analgesia without altering DOA.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
在适当深度的全身麻醉过程中,强刺激会在密度谱阵列中产生瞬时爆发抑制模式
利用脑电图(EEG)/脑电图处理来评估全身麻醉(GA)下对有害刺激的反应重新引起了人们的兴趣。我们提交了多项观察结果,探讨了在 GA 下受到强烈有害刺激时,SedLine Masimo 的密度谱阵列(DSA)中出现的瞬时爆发抑制模式(BSP)这一有趣现象。三名患者在足够深度的七氟醚/全静脉麻醉下接受了脊柱手术。在强烈的有害刺激下,DSA 上出现了突然的瞬时 BSP。传统上,血流动力学稳定的患者在 GA 下处理的 EEG/DSA 上出现 BSP 表示催眠过度。治疗方法通常是减少催眠药的剂量。在剧烈疼痛的情况下降低麻醉深度(DOA)可能会产生不良后果,尤其是对高危患者。意识到与剧烈疼痛刺激相关的脑电图/DSA 变化有助于麻醉师在不改变 DOA 的情况下滴定镇痛剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1