{"title":"Improving DNA recovery and sample throughput using the PrepFiler™ Automated Forensic DNA Extraction Kit on two customised Tecan Fluent® 1080 Automated Workstations","authors":"Nicholas J. O’Rourke,&nbsp;Nicholas S. Steele,&nbsp;Jasmine W. Tay,&nbsp;Colby M. Hymus,&nbsp;Nicholas S. Mountford,&nbsp;Tania M. Neave,&nbsp;Marie S. Rye","doi":"10.1016/j.fsir.2024.100384","DOIUrl":null,"url":null,"abstract":"<div><p>One of the primary goals of forensic laboratories performing DNA recovery and profiling is obtaining a high-quality DNA extract from crime scene samples. This is largely dependent on the sensitivity and reliability of the DNA extraction chemistry utilised, as well as the liquid handling and contamination minimisation techniques employed. Automation of DNA extraction methods on large liquid handling platforms allows high-throughput laboratories to apply sensitive chemistries to reliably process a large number of samples, while minimising manual processes and cross-contamination.</p><p>This study describes the first known implementation of the PrepFiler™ Automated Forensic DNA Extraction Kit on a Tecan Fluent® Gx 1080 Automation Workstation. Two Workstations were customised with the addition of novel “Safe Pipetting Modules” to eliminate sample crossover between wells, which is important in a forensic biology setting to reduce inadvertent DNA transfer. A comparison of DNA extraction efficiency between an optimised PrepFiler™ method and the DNA IQ™ System performed on a Perkin Elmer Janus® Integrator platform showed the optimised PrepFiler™ method consistently extracted a higher yield of DNA from a range of blood inputs, as well as blood and buccal swabs. The PrepFiler™ chemistry also more efficiently removed humic acid and haematin, reducing subsequent PCR inhibition. The subsequent implementation of the optimised PrepFiler™ method onto the Tecan Fluent® Gx workstations showed a further increase in sensitivity, with no evidence of DNA cross-contamination observed. However, the optimised PrepFiler™ method encountered difficulties extracting DNA from fabric substrates, with the PrepFiler <em>Express</em>™ chemistry extracting higher yields on the cartridge-based AutoMate <em>Express</em>™ System.</p><p>Overall, this study demonstrated the Tecan Fluent® Gx 1080 Automation Workstation is a sensitive, reliable and robust method for DNA extraction using the PrepFiler™ Automated Forensic DNA Extraction Kit, and the addition of the novel Safe Pipetting Module makes this platform an attractive option for forensic biology laboratories where minimising inadvertent DNA transfer is of paramount importance.</p></div>","PeriodicalId":36331,"journal":{"name":"Forensic Science International: Reports","volume":"10 ","pages":"Article 100384"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2665910724000331/pdfft?md5=46110917741b3c773b417e3b9393aed2&pid=1-s2.0-S2665910724000331-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Science International: Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2665910724000331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

One of the primary goals of forensic laboratories performing DNA recovery and profiling is obtaining a high-quality DNA extract from crime scene samples. This is largely dependent on the sensitivity and reliability of the DNA extraction chemistry utilised, as well as the liquid handling and contamination minimisation techniques employed. Automation of DNA extraction methods on large liquid handling platforms allows high-throughput laboratories to apply sensitive chemistries to reliably process a large number of samples, while minimising manual processes and cross-contamination.

This study describes the first known implementation of the PrepFiler™ Automated Forensic DNA Extraction Kit on a Tecan Fluent® Gx 1080 Automation Workstation. Two Workstations were customised with the addition of novel “Safe Pipetting Modules” to eliminate sample crossover between wells, which is important in a forensic biology setting to reduce inadvertent DNA transfer. A comparison of DNA extraction efficiency between an optimised PrepFiler™ method and the DNA IQ™ System performed on a Perkin Elmer Janus® Integrator platform showed the optimised PrepFiler™ method consistently extracted a higher yield of DNA from a range of blood inputs, as well as blood and buccal swabs. The PrepFiler™ chemistry also more efficiently removed humic acid and haematin, reducing subsequent PCR inhibition. The subsequent implementation of the optimised PrepFiler™ method onto the Tecan Fluent® Gx workstations showed a further increase in sensitivity, with no evidence of DNA cross-contamination observed. However, the optimised PrepFiler™ method encountered difficulties extracting DNA from fabric substrates, with the PrepFiler Express™ chemistry extracting higher yields on the cartridge-based AutoMate Express™ System.

Overall, this study demonstrated the Tecan Fluent® Gx 1080 Automation Workstation is a sensitive, reliable and robust method for DNA extraction using the PrepFiler™ Automated Forensic DNA Extraction Kit, and the addition of the novel Safe Pipetting Module makes this platform an attractive option for forensic biology laboratories where minimising inadvertent DNA transfer is of paramount importance.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在两台定制的 Tecan Fluent® 1080 自动化工作站上使用 PrepFiler™ 自动化法医 DNA 提取试剂盒,提高 DNA 回收率和样本处理量
法医实验室进行 DNA 复原和特征分析的主要目标之一是从犯罪现场样本中获得高质量的 DNA 提取物。这在很大程度上取决于所使用的 DNA 提取化学方法的灵敏度和可靠性,以及所采用的液体处理和污染最小化技术。大型液体处理平台上的 DNA 提取方法自动化允许高通量实验室使用灵敏的化学试剂可靠地处理大量样本,同时最大限度地减少手工操作和交叉污染。本研究描述了 PrepFiler™ 自动化法医 DNA 提取试剂盒在 Tecan Fluent® Gx 1080 自动化工作站上的首次已知实施。对两台工作站进行了定制,增加了新颖的 "安全移液模块",以消除孔间的样品交叉,这在法医生物学环境中对于减少意外的 DNA 转移非常重要。在珀金埃尔默 Janus® Integrator 平台上对经过优化的 PrepFiler™ 方法和 DNA IQ™ 系统的 DNA 提取效率进行了比较,结果表明经过优化的 PrepFiler™ 方法从一系列血液输入以及血液和颊拭子中提取的 DNA 产率更高。PrepFiler™ 化学方法还能更有效地去除腐殖酸和血红蛋白,减少随后的 PCR 抑制。随后在 Tecan Fluent® Gx 工作站上采用优化的 PrepFiler™ 方法,灵敏度进一步提高,没有发现 DNA 交叉污染的迹象。总之,这项研究表明 Tecan Fluent® Gx 1080 自动化工作站是一种灵敏、可靠、稳健的 DNA 提取方法,可以使用 PrepFiler™ 自动化法医 DNA 提取试剂盒提取 DNA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Forensic Science International: Reports
Forensic Science International: Reports Medicine-Pathology and Forensic Medicine
CiteScore
2.40
自引率
0.00%
发文量
47
审稿时长
57 days
期刊最新文献
Survey of bloodstain pattern analysts regarding pattern classifications on assorted fabrics Missing persons of post-conflict countries: Assessing dental identification through a questionnaire-based study in Syria Technical Report A light touch; Reviewing the relative effectiveness of light sources and physical/chemical techniques for fingermark retrieval in casework From death to the Virgin birth: Multi-analytical investigation of a suspected 16th century painting Medico-legal analysis of the correlation between head trauma and aneurysm rupture: A case report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1