Abibatou Konate-Toure, Valérie A Bedia-Tanoh, Fulgence K Kassi, Henriette Vanga-Bosson, Etienne K Angora, Estelle G M Kone, Sebastien A J Miezan, Vincent Djohan, Pulcherie C M Barro-Kiki, Hervé E I Menan, William Yavo
{"title":"Assessment of the performance of five malaria rapid diagnostic tests in health facilities in Abidjan (Côte d'Ivoire).","authors":"Abibatou Konate-Toure, Valérie A Bedia-Tanoh, Fulgence K Kassi, Henriette Vanga-Bosson, Etienne K Angora, Estelle G M Kone, Sebastien A J Miezan, Vincent Djohan, Pulcherie C M Barro-Kiki, Hervé E I Menan, William Yavo","doi":"10.17420/ap7002.525","DOIUrl":null,"url":null,"abstract":"<p><p>Regular monitoring of malaria rapid diagnostic tests (RDTs) for the management of uncomplicated malaria in healthcare facilities is a key factor in improving diagnostic quality and ensuring better case management. This study aimed to assess the performance of five RDTs (Standard Q Malaria P.f Ag and Standard Q Malaria P.f/Pan (SD Biosensor, Korea), One Step Malaria HRP2/pLDH (P.f/Pan) (Guangzhou Wondfo Biotech Co., Ltd., China), Malaria Pf/Pan (B&O Pharm, France), and Malaria test P.f/pan (Das Labor, Germany)) in two healthcare facilities in Abidjan. This cross-sectional study was conducted between September and October 2022. Overall, 250 patients suffering from uncomplicated malaria were included with a predominance of female patients (56.6%). The mean age was 22.3 years (SD = 20.6; range, 0.17-73). Of the patients tested, forty-six (46) tested positive for thick smears, reflecting a prevalence of 18.5%. Plasmodium falciparum was the most commonly detected species (93.5%). The geometric mean parasitemia was 6,111.80 parasites/μl (SD = 80,026.93) (range: 116-412461). The sensitivity ranged from 95.24% to 95.65%, whereas the specificity ranged from 93.07 to 94.09% for all five tests evaluated. The false positive rate of the tests was less than 10%. No invalid test results were reported. Two-thirds of P. malariae cases detected by microscopy showed also positive results with all the RDTs. All five RDTs showed 100% sensitivity at low parasitemia levels (< 1,000 parasites/μl blood) including three cases of parasites < 200 parasites/μl blood. This study demonstrated the importance of monitoring the performance of RDTs in clinical samples.</p>","PeriodicalId":7987,"journal":{"name":"Annals of parasitology","volume":"70 2","pages":"81-90"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of parasitology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17420/ap7002.525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Regular monitoring of malaria rapid diagnostic tests (RDTs) for the management of uncomplicated malaria in healthcare facilities is a key factor in improving diagnostic quality and ensuring better case management. This study aimed to assess the performance of five RDTs (Standard Q Malaria P.f Ag and Standard Q Malaria P.f/Pan (SD Biosensor, Korea), One Step Malaria HRP2/pLDH (P.f/Pan) (Guangzhou Wondfo Biotech Co., Ltd., China), Malaria Pf/Pan (B&O Pharm, France), and Malaria test P.f/pan (Das Labor, Germany)) in two healthcare facilities in Abidjan. This cross-sectional study was conducted between September and October 2022. Overall, 250 patients suffering from uncomplicated malaria were included with a predominance of female patients (56.6%). The mean age was 22.3 years (SD = 20.6; range, 0.17-73). Of the patients tested, forty-six (46) tested positive for thick smears, reflecting a prevalence of 18.5%. Plasmodium falciparum was the most commonly detected species (93.5%). The geometric mean parasitemia was 6,111.80 parasites/μl (SD = 80,026.93) (range: 116-412461). The sensitivity ranged from 95.24% to 95.65%, whereas the specificity ranged from 93.07 to 94.09% for all five tests evaluated. The false positive rate of the tests was less than 10%. No invalid test results were reported. Two-thirds of P. malariae cases detected by microscopy showed also positive results with all the RDTs. All five RDTs showed 100% sensitivity at low parasitemia levels (< 1,000 parasites/μl blood) including three cases of parasites < 200 parasites/μl blood. This study demonstrated the importance of monitoring the performance of RDTs in clinical samples.
期刊介绍:
The Annals of Parasitology (formerly Wiadomości Parazytologiczne) is an official, peer reviewed quarterly of the Polish Parasitological Society. The Annals of Parasitology publishes original papers, review articles, short notes and case reports in the fields of parasitology, mycology, and related disciplines. It also accepts interdisciplinary articles, scientific conference proceedings, book reviews. An important mission of our journal is to inform our Readers about the activities of the Polish Parasitological Society and advancement of parasitology both in Poland and elsewhere.