Oscillatory potential findings in patients with acute ischaemic central retinal vein occlusion.

IF 2 Q2 OPHTHALMOLOGY BMJ Open Ophthalmology Pub Date : 2024-08-13 DOI:10.1136/bmjophth-2023-001582
Ya Qu, Li Ran, Gang Wang, Min Wang, Shiying Li
{"title":"Oscillatory potential findings in patients with acute ischaemic central retinal vein occlusion.","authors":"Ya Qu, Li Ran, Gang Wang, Min Wang, Shiying Li","doi":"10.1136/bmjophth-2023-001582","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To explore the sensitive components of full-field electroretinography (ERG) as indicators of retina function at the onset of acute ischaemic central retinal vein occlusion (CRVO).</p><p><strong>Methods: </strong>11 patients (11 eyes) with ischaemic CRVO and 32 patients (32 eyes) with non-ischaemic CRVO who presented with first-episode unilateral CRVO within 1 month of symptom onset and with no previous intervention were examined by the International Society for Clinical Electrophysiology of Vision standard ERG.</p><p><strong>Results: </strong>A significant amplitude decline and peak time delay in light-adapted (LA) 3 ERG and LA 30 Hz flicker ERG (p<0.05 for all) was found in the ischaemic CRVO eyes, compared with the non-ischaemic CRVO eyes. The b/a amplitude ratio of dark-adapted (DA) 3 ERG, DA 10 ERG and LA 3 ERG was significantly different between the ischaemic and non-ischaemic groups (p<0.05 for all). Regarding oscillatory potentials (OPs), the amplitudes of OP1, OP2 and OP3 as well as the sum of DA 3 OP1-4 amplitudes (∑OPs) showed significant changes (p<0.01 for all) between two groups. No peak time delay of OPs was found between the ischaemic and non-ischaemic CRVO eyes.</p><p><strong>Conclusion: </strong>The amplitude of DA 0.01 ERG, components of LA 3 ERG and LA 30 Hz flicker ERG, and the b/a amplitude ratio could be among the most sensitive indicators in patients with acute ischaemic CRVO. The amplitudes of OP1, OP2, OP3 and ∑OPs in the CRVO eyes were reduced to 40% of the control values, showing that this quantitative method is reliable for detecting ischaemic retinal diseases, even in early stage.</p>","PeriodicalId":9286,"journal":{"name":"BMJ Open Ophthalmology","volume":"9 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11331877/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjophth-2023-001582","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: To explore the sensitive components of full-field electroretinography (ERG) as indicators of retina function at the onset of acute ischaemic central retinal vein occlusion (CRVO).

Methods: 11 patients (11 eyes) with ischaemic CRVO and 32 patients (32 eyes) with non-ischaemic CRVO who presented with first-episode unilateral CRVO within 1 month of symptom onset and with no previous intervention were examined by the International Society for Clinical Electrophysiology of Vision standard ERG.

Results: A significant amplitude decline and peak time delay in light-adapted (LA) 3 ERG and LA 30 Hz flicker ERG (p<0.05 for all) was found in the ischaemic CRVO eyes, compared with the non-ischaemic CRVO eyes. The b/a amplitude ratio of dark-adapted (DA) 3 ERG, DA 10 ERG and LA 3 ERG was significantly different between the ischaemic and non-ischaemic groups (p<0.05 for all). Regarding oscillatory potentials (OPs), the amplitudes of OP1, OP2 and OP3 as well as the sum of DA 3 OP1-4 amplitudes (∑OPs) showed significant changes (p<0.01 for all) between two groups. No peak time delay of OPs was found between the ischaemic and non-ischaemic CRVO eyes.

Conclusion: The amplitude of DA 0.01 ERG, components of LA 3 ERG and LA 30 Hz flicker ERG, and the b/a amplitude ratio could be among the most sensitive indicators in patients with acute ischaemic CRVO. The amplitudes of OP1, OP2, OP3 and ∑OPs in the CRVO eyes were reduced to 40% of the control values, showing that this quantitative method is reliable for detecting ischaemic retinal diseases, even in early stage.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
急性缺血性视网膜中央静脉闭塞患者的振荡电位发现。
目的:探讨在急性缺血性视网膜中央静脉闭塞(CRVO)发病时,全视场视网膜电图(ERG)的敏感成分作为视网膜功能的指标。方法:采用国际视力临床电生理学会标准ERG对11例缺血性CRVO患者(11眼)和32例非缺血性CRVO患者(32眼)进行检查,这些患者在症状出现后1个月内首次出现单侧CRVO,且之前未进行过干预:结果:光适应(LA)3 ERG和LA 30 Hz闪烁ERG的振幅明显下降,峰值时间明显延迟(p结论:DA 0.01 ERG 的振幅、LA 3 ERG 和 LA 30 Hz 闪烁 ERG 的成分以及 b/a 振幅比可能是急性缺血性 CRVO 患者最敏感的指标之一。CRVO眼的OP1、OP2、OP3和∑OP的振幅降低到对照值的40%,这表明这种定量方法即使在早期也能可靠地检测缺血性视网膜疾病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMJ Open Ophthalmology
BMJ Open Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
4.20%
发文量
104
审稿时长
20 weeks
期刊最新文献
Investigation of choroidal vascular alterations in eyes with myopia using ultrawidefield optical coherence tomography angiography. Recent advances in the application of artificial intelligence in age-related macular degeneration. Network-based hub biomarker discovery for glaucoma. Investigating the effects of simulated high altitude on colour discrimination. Total retinal thickness is an important factor in evaluating diabetic retinal neurodegeneration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1