{"title":"Improved Robustness for Deep Learning-based Segmentation of Multi-Center Myocardial Perfusion MRI Datasets Using Data Adaptive Uncertainty-guided Space-time Analysis.","authors":"Dilek M Yalcinkaya, Khalid Youssef, Bobak Heydari, Janet Wei, Noel Bairey Merz, Robert Judd, Rohan Dharmakumar, Orlando P Simonetti, Jonathan W Weinsaft, Subha V Raman, Behzad Sharif","doi":"10.1016/j.jocmr.2024.101082","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Fully automatic analysis of myocardial perfusion MRI datasets enables rapid and objective reporting of stress/rest studies in patients with suspected ischemic heart disease. Developing deep learning techniques that can analyze multi-center datasets despite limited training data and variations in software (pulse sequence) and hardware (scanner vendor) is an ongoing challenge.</p><p><strong>Methods: </strong>Datasets from 3 medical centers acquired at 3T (n = 150 subjects; 21,150 first-pass images) were included: an internal dataset (inD; n = 95) and two external datasets (exDs; n = 55) used for evaluating the robustness of the trained deep neural network (DNN) models against differences in pulse sequence (exD-1) and scanner vendor (exD-2). A subset of inD (n = 85) was used for training/validation of a pool of DNNs for segmentation, all using the same spatiotemporal U-Net architecture and hyperparameters but with different parameter initializations. We employed a space-time sliding-patch analysis approach that automatically yields a pixel-wise \"uncertainty map\" as a byproduct of the segmentation process. In our approach, dubbed Data Adaptive Uncertainty-Guided Space-time (DAUGS) analysis, a given test case is segmented by all members of the DNN pool and the resulting uncertainty maps are leveraged to automatically select the \"best\" one among the pool of solutions. For comparison, we also trained a DNN using the established approach with the same settings (hyperparameters, data augmentation, etc.).</p><p><strong>Results: </strong>The proposed DAUGS analysis approach performed similarly to the established approach on the internal dataset (Dice score for the testing subset of inD: 0.896 ± 0.050 vs. 0.890 ± 0.049; p = n.s.) whereas it significantly outperformed on the external datasets (Dice for exD-1: 0.885 ± 0.040 vs. 0.849 ± 0.065, p < 0.005; Dice for exD-2: 0.811 ± 0.070 vs. 0.728 ± 0.149, p < 0.005). Moreover, the number of image series with \"failed\" segmentation (defined as having myocardial contours that include bloodpool or are noncontiguous in ≥1 segment) was significantly lower for the proposed vs. the established approach (4.3% vs. 17.1%, p < 0.0005).</p><p><strong>Conclusions: </strong>The proposed DAUGS analysis approach has the potential to improve the robustness of deep learning methods for segmentation of multi-center stress perfusion datasets with variations in the choice of pulse sequence, site location or scanner vendor.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"101082"},"PeriodicalIF":4.2000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2024.101082","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Fully automatic analysis of myocardial perfusion MRI datasets enables rapid and objective reporting of stress/rest studies in patients with suspected ischemic heart disease. Developing deep learning techniques that can analyze multi-center datasets despite limited training data and variations in software (pulse sequence) and hardware (scanner vendor) is an ongoing challenge.

Methods: Datasets from 3 medical centers acquired at 3T (n = 150 subjects; 21,150 first-pass images) were included: an internal dataset (inD; n = 95) and two external datasets (exDs; n = 55) used for evaluating the robustness of the trained deep neural network (DNN) models against differences in pulse sequence (exD-1) and scanner vendor (exD-2). A subset of inD (n = 85) was used for training/validation of a pool of DNNs for segmentation, all using the same spatiotemporal U-Net architecture and hyperparameters but with different parameter initializations. We employed a space-time sliding-patch analysis approach that automatically yields a pixel-wise "uncertainty map" as a byproduct of the segmentation process. In our approach, dubbed Data Adaptive Uncertainty-Guided Space-time (DAUGS) analysis, a given test case is segmented by all members of the DNN pool and the resulting uncertainty maps are leveraged to automatically select the "best" one among the pool of solutions. For comparison, we also trained a DNN using the established approach with the same settings (hyperparameters, data augmentation, etc.).

Results: The proposed DAUGS analysis approach performed similarly to the established approach on the internal dataset (Dice score for the testing subset of inD: 0.896 ± 0.050 vs. 0.890 ± 0.049; p = n.s.) whereas it significantly outperformed on the external datasets (Dice for exD-1: 0.885 ± 0.040 vs. 0.849 ± 0.065, p < 0.005; Dice for exD-2: 0.811 ± 0.070 vs. 0.728 ± 0.149, p < 0.005). Moreover, the number of image series with "failed" segmentation (defined as having myocardial contours that include bloodpool or are noncontiguous in ≥1 segment) was significantly lower for the proposed vs. the established approach (4.3% vs. 17.1%, p < 0.0005).

Conclusions: The proposed DAUGS analysis approach has the potential to improve the robustness of deep learning methods for segmentation of multi-center stress perfusion datasets with variations in the choice of pulse sequence, site location or scanner vendor.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用数据自适应不确定性引导的时空分析提高基于深度学习的多中心心肌灌注 MRI 数据集分割的鲁棒性
背景:对心肌灌注 MRI 数据集进行全自动分析可快速、客观地报告疑似缺血性心脏病患者的应激/静息研究结果。尽管训练数据有限,且软件(脉冲序列)和硬件(扫描仪供应商)存在差异,但开发能够分析多中心数据集的深度学习技术仍是一项持续的挑战:方法: 包括3个医疗中心在3T采集的数据集(n = 150名受试者;21,150幅第一次通过图像):一个内部数据集(inD;n = 95)和两个外部数据集(exDs;n = 55),用于评估训练好的深度神经网络(DNN)模型对脉冲序列(exD-1)和扫描仪供应商(exD-2)差异的鲁棒性。inD子集(n = 85)用于训练/验证用于分割的DNN池,所有DNN均使用相同的时空U-Net架构和超参数,但参数初始化不同。我们采用了一种时空滑动补丁分析方法,作为分割过程的副产品,它能自动生成像素级的 "不确定性图"。我们的方法被称为 "数据自适应不确定性引导的时空(DAUGS)分析",一个给定的测试案例由 DNN 池中的所有成员进行分割,并利用由此产生的不确定性图在解决方案池中自动选择 "最佳 "解决方案。为了进行比较,我们还使用相同设置(超参数、数据增强等)的既定方法训练了 DNN:结果:提议的 DAUGS 分析方法在内部数据集上的表现与既定方法相似(inD 测试子集的 Dice 分数:0.896 ± 0.050 vs. 0.890 ± 0.049;p = n. s.s.),而在外部数据集上则明显优于内部数据集(exD-1 的 Dice 分数:0.885 ± 0.040 vs. 0.849 ± 0.065,p < 0.005;exD-2 的 Dice 分数:0.811 ± 0.070 vs. 0.728 ± 0.149,p < 0.005)。此外,建议方法与既有方法相比,"分割失败"(定义为心肌轮廓包含血池或≥1个节段不连续)的图像系列数量显著减少(4.3% vs. 17.1%,p < 0.0005):所提出的 DAUGS 分析方法有可能提高深度学习方法的稳健性,以便在脉冲序列、站点位置或扫描仪供应商选择不同的情况下分割多中心压力灌注数据集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
10.90
自引率
12.50%
发文量
61
审稿时长
6-12 weeks
期刊介绍: Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to: New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system. New methods to enhance or accelerate image acquisition and data analysis. Results of multicenter, or larger single-center studies that provide insight into the utility of CMR. Basic biological perceptions derived by CMR methods.
期刊最新文献
Absence of cardiac impairment in patients after SARS-CoV-2 infection: a long-term follow-up study. Simultaneous Multislice Cardiac Multimapping based on Locally Low-Rank and Sparsity Constraints. Joint suppression of cardiac bSSFP cine banding and flow artifacts using twofold phase-cycling and a dual-encoder neural network. Non-Invasively Measured Myocardial Torsional Modulus: Comparison to Invasive Evaluation of Diastolic Function. Design and Rationale of MYOFLAME-19 RCT: MYOcardial protection to reduce inFLAMmatory heart disease due to COVID-19 Infection using CMR Endpoints.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1