Outcomes of a hydroxyapatite ceramic-coated femoral stem in primary total hip arthroplasty: a report of excellent survivorship from a single United Kingdom centre.

IF 1.8 Q2 ORTHOPEDICS SICOT-J Pub Date : 2024-01-01 Epub Date: 2024-08-14 DOI:10.1051/sicotj/2024026
Karim M Abdelghafour, Sherif A Khaled, Khaled F M Abdel-Kader, Hazem A Azeem, Nirav N Shah
{"title":"Outcomes of a hydroxyapatite ceramic-coated femoral stem in primary total hip arthroplasty: a report of excellent survivorship from a single United Kingdom centre.","authors":"Karim M Abdelghafour, Sherif A Khaled, Khaled F M Abdel-Kader, Hazem A Azeem, Nirav N Shah","doi":"10.1051/sicotj/2024026","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hydroxyapatite (HA) coated femoral stems were introduced to enhance the biological fixation at the implant-bone interface, aiming to increase the longevity and survival of the prostheses. We aimed to assess the long-term outcomes of an HA ceramic (HAC) coated stem in primary total hip arthroplasty (THA), assess the stem survival, and clinically evaluate the patients using patient-reported outcome measures (PROMs) and radiological evaluation of stem osseointegration.</p><p><strong>Patients and methods: </strong>This was a prospective evaluation of a retrospective cohort of 385 patients (442 hips) who underwent primary THA between June 2008 and December 2018. The mean age was 63.83 years (range, 30-82 years). During the follow-up duration, 23 patients died, and 36 patients (38 hips) were lost to follow-up. Prospective data collected for 326 patients (381 hips) was used to evaluate stem survival with the Kaplan-Meier method using aseptic loosening or any revision as the endpoint. Clinical evaluation was done using the EuroQol five-dimension (EQ-5D) scoring system and PROMs using the Oxford Hip Score (OHS) and Merle D'Aubigne Postel (MDP) score. Radiological assessments were performed using the Engh radiological criteria for stem osteointegration.</p><p><strong>Results: </strong>The mean follow-up duration was 9.39 years (range, 4-14.5 years). The survival of the HAC-coated femoral stem was 100% (95% confidence interval [CI], 96.7-100%) at 14 years with aseptic loosening as the endpoint, and 98.9% (CI, 96.7-100%) at 14 years with stem revision for any reason as the endpoint. The mean OHS was 44.5 (range, 30-48), and the mean MDP score was 15.87 (range, 10-18). Radiological evaluations showed full osseointegration of all stems.</p><p><strong>Conclusion: </strong>This HAC-coated femoral stem has shown excellent survivorship, functional outcomes, and full osseointegration at the final follow-up.</p>","PeriodicalId":46378,"journal":{"name":"SICOT-J","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11325862/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICOT-J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/sicotj/2024026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Hydroxyapatite (HA) coated femoral stems were introduced to enhance the biological fixation at the implant-bone interface, aiming to increase the longevity and survival of the prostheses. We aimed to assess the long-term outcomes of an HA ceramic (HAC) coated stem in primary total hip arthroplasty (THA), assess the stem survival, and clinically evaluate the patients using patient-reported outcome measures (PROMs) and radiological evaluation of stem osseointegration.

Patients and methods: This was a prospective evaluation of a retrospective cohort of 385 patients (442 hips) who underwent primary THA between June 2008 and December 2018. The mean age was 63.83 years (range, 30-82 years). During the follow-up duration, 23 patients died, and 36 patients (38 hips) were lost to follow-up. Prospective data collected for 326 patients (381 hips) was used to evaluate stem survival with the Kaplan-Meier method using aseptic loosening or any revision as the endpoint. Clinical evaluation was done using the EuroQol five-dimension (EQ-5D) scoring system and PROMs using the Oxford Hip Score (OHS) and Merle D'Aubigne Postel (MDP) score. Radiological assessments were performed using the Engh radiological criteria for stem osteointegration.

Results: The mean follow-up duration was 9.39 years (range, 4-14.5 years). The survival of the HAC-coated femoral stem was 100% (95% confidence interval [CI], 96.7-100%) at 14 years with aseptic loosening as the endpoint, and 98.9% (CI, 96.7-100%) at 14 years with stem revision for any reason as the endpoint. The mean OHS was 44.5 (range, 30-48), and the mean MDP score was 15.87 (range, 10-18). Radiological evaluations showed full osseointegration of all stems.

Conclusion: This HAC-coated femoral stem has shown excellent survivorship, functional outcomes, and full osseointegration at the final follow-up.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
羟基磷灰石陶瓷涂层股骨柄在初级全髋关节置换术中的效果:一份来自英国单一中心的极佳存活率报告。
背景:羟基磷灰石(HA)涂层股骨柄的引入是为了增强植入物与骨界面的生物固定,从而延长假体的寿命和存活率。我们的目的是评估HA陶瓷(HAC)涂层股骨柄在初级全髋关节置换术(THA)中的长期疗效、评估股骨柄的存活率,并使用患者报告的疗效指标(PROMs)和股骨柄骨结合的放射学评估对患者进行临床评估:这是对2008年6月至2018年12月期间接受初级THA的385名患者(442个髋关节)的回顾性队列进行的前瞻性评估。平均年龄为63.83岁(30-82岁)。随访期间,23 名患者死亡,36 名患者(38 个髋关节)失去随访机会。收集到的326名患者(381个髋关节)的前瞻性数据采用Kaplan-Meier法,以无菌性松动或任何翻修为终点,评估骨干存活率。临床评估采用EuroQol五维(EQ-5D)评分系统,PROM采用牛津髋关节评分(OHS)和Merle D'Aubigne Postel评分(MDP)。放射学评估采用恩格(Engh)髋关节骨整合放射学标准:平均随访时间为9.39年(4-14.5年)。以无菌性松动为终点,HAC涂层股骨柄14年的存活率为100%(95%置信区间[CI],96.7-100%);以任何原因的柄翻修为终点,HAC涂层股骨柄14年的存活率为98.9%(CI,96.7-100%)。平均OHS为44.5(范围为30-48),平均MDP评分为15.87(范围为10-18)。放射学评估显示,所有股骨柄均完全骨结合:结论:这种HAC涂层股骨柄显示了极佳的存活率、功能性结果以及最终随访时的完全骨结合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
SICOT-J
SICOT-J ORTHOPEDICS-
CiteScore
3.20
自引率
12.50%
发文量
44
审稿时长
14 weeks
期刊最新文献
Combining inertial navigation with transacetabular ligament in total hip arthroplasty via direct anterior approach results in excellent accuracy compared to standard manual technique Flexion contracture can cause component mismatch in the Prophecy® preoperative patient-specific instrumentation for Evolution® medial-pivot knee system Vitamin D deficiency in Scheuermann’s disease is associated with increased adverse outcomes Adapting hip arthroplasty practices during the COVID-19 pandemic: Assessing the impact of outpatient care sudden increase on early complications and clinical outcomes. Outcomes of total hip arthroplasty using dual mobility cups following failed internal fixation of proximal femoral fractures at a mean follow-up of 6 years.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1