Comparison of sample materials for S100b analysis.

IF 1.3 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2024-09-01 Epub Date: 2024-08-17 DOI:10.1080/00365513.2024.2392247
Kasper Krogh Nielsen, Claus Vinter Bødker Hviid, Aase Handberg, Peter Astrup Christensen
{"title":"Comparison of sample materials for S100b analysis.","authors":"Kasper Krogh Nielsen, Claus Vinter Bødker Hviid, Aase Handberg, Peter Astrup Christensen","doi":"10.1080/00365513.2024.2392247","DOIUrl":null,"url":null,"abstract":"<p><p>Head injury is a potentially lethal and frequently occurring condition in the emergency department (ED). Reliable and fast diagnosis is important both for patients and flow in the ED. Circulating S100B is used to rule out the need for head computer tomography in low-risk patients with mild head injury. The flow of these patients through the ED would benefit from shorter turn-around time. Standard serum clotting tubes require 30-60 min clotting time, followed by an analysis time of 45 min. Here, we evaluated the performance of two alternative blood collection tubes; a rapid serum tube (RST) with a recommend clotting time of 5 min and a hirudin tube (HIR) for instant anticoagulation. S100B measurement was performed on paired blood samples from 221 subjects using a Roche Cobas 602 analyser. The performances of the alternative tubes were evaluated by method comparison to the standard serum clotting tube, repeatability and agreement of results obtained from alternative tubes compared with the standard clotting tube. Both alternative tubes had a minor positive bias (RST = 0.011 µg/L, HIR = 0.008 µg/L). The repeatability was 2% for RST and 10% for HIR, while being 4% for the standard clotting tube. In the agreement analysis, the positive and negative predictive values for RST were 62% and 100% while being 73% and 99% for HIR respectively. Our study suggests that RST is a feasible alternative to reduce laboratory turn-around time in S100b analysis.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"345-349"},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2392247","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/17 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Head injury is a potentially lethal and frequently occurring condition in the emergency department (ED). Reliable and fast diagnosis is important both for patients and flow in the ED. Circulating S100B is used to rule out the need for head computer tomography in low-risk patients with mild head injury. The flow of these patients through the ED would benefit from shorter turn-around time. Standard serum clotting tubes require 30-60 min clotting time, followed by an analysis time of 45 min. Here, we evaluated the performance of two alternative blood collection tubes; a rapid serum tube (RST) with a recommend clotting time of 5 min and a hirudin tube (HIR) for instant anticoagulation. S100B measurement was performed on paired blood samples from 221 subjects using a Roche Cobas 602 analyser. The performances of the alternative tubes were evaluated by method comparison to the standard serum clotting tube, repeatability and agreement of results obtained from alternative tubes compared with the standard clotting tube. Both alternative tubes had a minor positive bias (RST = 0.011 µg/L, HIR = 0.008 µg/L). The repeatability was 2% for RST and 10% for HIR, while being 4% for the standard clotting tube. In the agreement analysis, the positive and negative predictive values for RST were 62% and 100% while being 73% and 99% for HIR respectively. Our study suggests that RST is a feasible alternative to reduce laboratory turn-around time in S100b analysis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于 S100b 分析的样本材料比较。
头部损伤是急诊科(ED)中经常出现的一种潜在致命疾病。可靠、快速的诊断对患者和急诊室的人流都很重要。循环 S100B 可用于排除轻微头部损伤的低风险患者是否需要进行头部计算机断层扫描。缩短周转时间对急诊室的患者流量大有裨益。标准的血清凝固试管需要 30-60 分钟的凝固时间,然后需要 45 分钟的分析时间。在这里,我们评估了两种可供选择的采血管的性能;一种是建议凝血时间为 5 分钟的快速血清管 (RST),另一种是用于即时抗凝的水蛭素管 (HIR)。使用罗氏 Cobas 602 分析仪对 221 名受试者的配对血样进行了 S100B 测量。通过与标准血清凝血试管的方法比较、重复性以及替代试管与标准凝血试管所得结果的一致性,对替代试管的性能进行了评估。两种替代试管都有轻微的正偏差(RST = 0.011 µg/L,HIR = 0.008 µg/L)。RST 的重复性为 2%,HIR 为 10%,而标准凝血试管的重复性为 4%。在一致性分析中,RST 的阳性预测值为 62%,阴性预测值为 100%,而 HIR 的阳性预测值为 73%,阴性预测值为 99%。我们的研究表明,RST 是一种可行的替代方法,可缩短 S100b 分析的实验室周转时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
期刊最新文献
Analytical interference on measurement of immunoglobulins in monoclonal gammopathy. FlowDiff: a simple, flow cytometry-based approach for performing a leukocyte differential count. Reference intervals for 23 common biochemical parameters during pregnancy and the first six postpartum months. Prevalence of monoclonal proteins in patients with isolated hypogammaglobulinemia on serum protein electrophoresis. Challenges of preanalytical variables in erythrocyte sedimentation rate: a CUBE 30 touch evaluation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1