Karel T N Breeman, Reinoud E Knops, Michelle D van der Stoel, Lucas V A Boersma, Sing-Chien Yap, Lieselot van Erven, Vincent F van Dijk, Alexander H Maass, Arthur A M Wilde, Fleur V Y Tjong
{"title":"Trends in adoption of extravascular cardiac implantable electronic devices: the Dutch cohort.","authors":"Karel T N Breeman, Reinoud E Knops, Michelle D van der Stoel, Lucas V A Boersma, Sing-Chien Yap, Lieselot van Erven, Vincent F van Dijk, Alexander H Maass, Arthur A M Wilde, Fleur V Y Tjong","doi":"10.1007/s12471-024-01892-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Conventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry a risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking.</p><p><strong>Objective: </strong>To assess real-world nationwide trends in EVD adoption in the Netherlands.</p><p><strong>Methods: </strong>Using the Netherlands Heart Registration, all consecutive patients with a de novo S‑ICD or conventional single-chamber ICD implantation between 2012-2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014-2020 were included. Trends in adoption are described for various patient and centre characteristics.</p><p><strong>Result: </strong>From 2012-2020, 2190 S‑ICDs and 10,683 conventional ICDs were implanted; from 2014-2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached a plateau. S‑ICD recipients were younger than conventional ICD recipients (p < 0.001) and more often female (p < 0.001); LP recipients were younger than conventional pacemaker recipients (p < 0.001) and more often male (p = 0.03). Both S‑ICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time S‑ICDs were increasingly implanted in centres without cardiothoracic surgery (p < 0.001).</p><p><strong>Conclusion: </strong>This nationwide study demonstrated a relatively quick adoption of innovative EVDs with a plateau after approximately 4 years. S‑ICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but S‑ICD use is expanding beyond those centres.</p>","PeriodicalId":18952,"journal":{"name":"Netherlands Heart Journal","volume":" ","pages":"356-362"},"PeriodicalIF":1.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413308/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Netherlands Heart Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12471-024-01892-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Conventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry a risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking.
Objective: To assess real-world nationwide trends in EVD adoption in the Netherlands.
Methods: Using the Netherlands Heart Registration, all consecutive patients with a de novo S‑ICD or conventional single-chamber ICD implantation between 2012-2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014-2020 were included. Trends in adoption are described for various patient and centre characteristics.
Result: From 2012-2020, 2190 S‑ICDs and 10,683 conventional ICDs were implanted; from 2014-2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached a plateau. S‑ICD recipients were younger than conventional ICD recipients (p < 0.001) and more often female (p < 0.001); LP recipients were younger than conventional pacemaker recipients (p < 0.001) and more often male (p = 0.03). Both S‑ICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time S‑ICDs were increasingly implanted in centres without cardiothoracic surgery (p < 0.001).
Conclusion: This nationwide study demonstrated a relatively quick adoption of innovative EVDs with a plateau after approximately 4 years. S‑ICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but S‑ICD use is expanding beyond those centres.
期刊介绍:
The scope of the Netherlands Heart Journal is to contribute to the national and international literature by publishing scientific papers in the field of cardiovascular medicine. It also provides a platform for Continuing Medical Education for cardiologists and those in training for the speciality of cardiology in the Netherlands.