Intraindividual Comparison of Image Artifacts of Two Generations of Rotatable Cochlear Implant Magnets.

Rayoung Kim, Simon Schleyer, Hans Björn Gehl, Holger Sudhoff, Peter Goon, Ingo Todt
{"title":"Intraindividual Comparison of Image Artifacts of Two Generations of Rotatable Cochlear Implant Magnets.","authors":"Rayoung Kim, Simon Schleyer, Hans Björn Gehl, Holger Sudhoff, Peter Goon, Ingo Todt","doi":"10.5152/iao.2024.231466","DOIUrl":null,"url":null,"abstract":"<p><p>In cochlear implant recipients, the diagnostic value of magnetic resonance imaging (MRI) scans is reduced by image artifacts. The static magnetic field of a 3.0T scanner is associated with the risk of implant demagnetization. The development of rotatable implant magnets aimed to support the advancement of 3.0T MRI scanners and eliminate the risk of demagnetization of cochlear implant magnets. This study aimed to compare the image artifacts caused by first-t and second-generation rotatable cochlear implant magnets in 3.0T MRI. Three Tesla MRI T2W TSE sequences were performed on 3 subjects with first- and second-generation rotatable cochlear implant magnets. The cochlear implant was fixed to the head at the implantation position by a swim cap. The size of the image artifact was determined in the transverse plane. Intraindividual comparative analyses showed that within the margin of combined uncertainty of 5 mm at a resolution of 2 mm, the cochlear implant-induced image artifacts in all subjects showed for both (first- and second-generation rotatable cochlear implant magnets), the same maximum image artifact dimension of 125 mm. We could show that no difference in image artifact size was detected within the margin of error determined by resolution, localized induced shift of the scan, and reproducibility of the tilt angle of the head relative to the chest in a living subject. Assumed improved magnet attachment can be reached without compromising of the magnet artifact size.</p>","PeriodicalId":94238,"journal":{"name":"The journal of international advanced otology","volume":"20 4","pages":"306-311"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11363200/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of international advanced otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/iao.2024.231466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In cochlear implant recipients, the diagnostic value of magnetic resonance imaging (MRI) scans is reduced by image artifacts. The static magnetic field of a 3.0T scanner is associated with the risk of implant demagnetization. The development of rotatable implant magnets aimed to support the advancement of 3.0T MRI scanners and eliminate the risk of demagnetization of cochlear implant magnets. This study aimed to compare the image artifacts caused by first-t and second-generation rotatable cochlear implant magnets in 3.0T MRI. Three Tesla MRI T2W TSE sequences were performed on 3 subjects with first- and second-generation rotatable cochlear implant magnets. The cochlear implant was fixed to the head at the implantation position by a swim cap. The size of the image artifact was determined in the transverse plane. Intraindividual comparative analyses showed that within the margin of combined uncertainty of 5 mm at a resolution of 2 mm, the cochlear implant-induced image artifacts in all subjects showed for both (first- and second-generation rotatable cochlear implant magnets), the same maximum image artifact dimension of 125 mm. We could show that no difference in image artifact size was detected within the margin of error determined by resolution, localized induced shift of the scan, and reproducibility of the tilt angle of the head relative to the chest in a living subject. Assumed improved magnet attachment can be reached without compromising of the magnet artifact size.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两代可旋转人工耳蜗磁铁图像伪影的个体内比较。
对于人工耳蜗植入者,磁共振成像(MRI)扫描的诊断价值会因图像伪影而降低。3.0T 扫描仪的静态磁场与植入体退磁的风险有关。可旋转植入磁体的开发旨在支持 3.0T MRI 扫描仪的发展,消除人工耳蜗植入磁体的退磁风险。本研究旨在比较第一代和第二代可旋转人工耳蜗磁体在 3.0T 磁共振成像中造成的图像伪影。研究人员对 3 名使用第一代和第二代可旋转人工耳蜗磁体的受试者进行了三特斯拉 MRI T2W TSE 序列检查。人工耳蜗通过泳帽固定在植入位置的头部。在横向平面上确定图像伪影的大小。个体内比较分析表明,在分辨率为 2 毫米的情况下,在 5 毫米的综合不确定性范围内,所有受试者(第一代和第二代可旋转人工耳蜗磁体)的人工耳蜗引起的图像伪影的最大尺寸均为 125 毫米。我们可以证明,在由分辨率、扫描的局部诱导偏移以及活体受试者头部相对于胸部的倾斜角度的可重复性决定的误差范围内,没有检测到图像伪影大小的差异。假定磁铁附着性得到改善,但不会影响磁铁伪影的大小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An International Survey of the Diagnosis and Management of Ménière's Disease Amongst Otolaryngology Consultants. Associations of Blood Lipids with the Risk and Prognosis of Sudden Sensorineural Hearing Loss: A Meta-analysis. Auditory Memory and Visual Memory in Typically Developing Children: Modality Dependence/ Independence. Auditory Memory and Visual Memory in Typically Developing Children: Modality Dependence/ Independence. Constant Dizziness Versus Episodic Vertigo in Ménière's Disease: Health-Related Quality of Life, Cognitive Dissonance, and Postural Problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1