3D-printed zirconia orthodontic brackets: Effect of printing method on dimensional accuracy.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-08-21 DOI:10.1111/ocr.12847
Zhi Tang, Jingtao Dai, Anlan Yu, Ping Li, Chufeng Liu, Xiaoqing Shen
{"title":"3D-printed zirconia orthodontic brackets: Effect of printing method on dimensional accuracy.","authors":"Zhi Tang, Jingtao Dai, Anlan Yu, Ping Li, Chufeng Liu, Xiaoqing Shen","doi":"10.1111/ocr.12847","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study investigated the effect of additive manufacturing (AM) methods on the slot height dimensions and accuracy of 3D-printed orthodontic brackets.</p><p><strong>Methods: </strong>A 3D model of a standard Mclaughlin Bennett Trevisi bracket was used as a reference to print the ceramic bracket in a 90° orientation using two representative AM methods: digital light processing (DLP) and material jetting (MJ). The dimensional accuracy and slot heights were determined using a scanning electron microscope and an optical scanner. Also, all specimens were analysed using the Geomagic Control X 3D inspection software. The root mean square (RMS) values were used for trueness and precision assessment. Statistical analyses were performed using an independent sample t-test.</p><p><strong>Results: </strong>Slot height dimensions, trueness RMS, and precision RMS were statistically affected by different AM methods (p < .01). There was a significant difference between the different printing methods, with DLP meeting the tolerance requirements (mean slot height = 0.557 ± 0.018 mm) and MJ being slightly below them (mean slot height = 0.544 ± 0.021 mm). However, MJ significantly outperformed DLP in terms of accuracy. Among the two printing methods, MJ was associated with higher trueness (RMS = 0.025 ± 0.004 mm) and precision (RMS = 0.038 ± 0.005 mm).</p><p><strong>Conclusions: </strong>Both tested AM methods yielded clinically acceptable outcomes, with the RMS range set to ±100 μm and the slot height tolerance established at 0.549-0.569 mm. The MJ technology achieved the highest accuracy.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/ocr.12847","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study investigated the effect of additive manufacturing (AM) methods on the slot height dimensions and accuracy of 3D-printed orthodontic brackets.

Methods: A 3D model of a standard Mclaughlin Bennett Trevisi bracket was used as a reference to print the ceramic bracket in a 90° orientation using two representative AM methods: digital light processing (DLP) and material jetting (MJ). The dimensional accuracy and slot heights were determined using a scanning electron microscope and an optical scanner. Also, all specimens were analysed using the Geomagic Control X 3D inspection software. The root mean square (RMS) values were used for trueness and precision assessment. Statistical analyses were performed using an independent sample t-test.

Results: Slot height dimensions, trueness RMS, and precision RMS were statistically affected by different AM methods (p < .01). There was a significant difference between the different printing methods, with DLP meeting the tolerance requirements (mean slot height = 0.557 ± 0.018 mm) and MJ being slightly below them (mean slot height = 0.544 ± 0.021 mm). However, MJ significantly outperformed DLP in terms of accuracy. Among the two printing methods, MJ was associated with higher trueness (RMS = 0.025 ± 0.004 mm) and precision (RMS = 0.038 ± 0.005 mm).

Conclusions: Both tested AM methods yielded clinically acceptable outcomes, with the RMS range set to ±100 μm and the slot height tolerance established at 0.549-0.569 mm. The MJ technology achieved the highest accuracy.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三维打印氧化锆正畸托槽:打印方法对尺寸精度的影响
目的:本研究探讨了增材制造(AM)方法对 3D 打印正畸托槽槽高尺寸和精度的影响:本研究调查了增材制造(AM)方法对三维打印正畸托槽槽高尺寸和精度的影响:以标准 Mclaughlin Bennett Trevisi 托槽的三维模型为参考,使用两种具有代表性的 AM 方法:数字光处理 (DLP) 和材料喷射 (MJ) 以 90° 方向打印陶瓷托槽。使用扫描电子显微镜和光学扫描仪确定了尺寸精度和槽高度。此外,还使用 Geomagic Control X 3D 检测软件对所有试样进行了分析。均方根(RMS)值用于真实度和精度评估。统计分析采用独立样本 t 检验:结果:槽高度尺寸、真实度均方根和精度均方根受不同 AM 方法的统计影响(p 结论:两种测试 AM 方法都能获得临床意义上的槽高度尺寸、真实度均方根和精度均方根:所测试的两种 AM 方法都获得了临床上可接受的结果,均方根范围设定为 ±100 μm,槽高度公差设定为 0.549-0.569 mm。MJ 技术的精确度最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1