Sameh Hany Emile, Justin Dourado, Peter Rogers, Anjelli Wignakumar, Nir Horesh, Zoe Garoufalia, Rachel Gefen, Steven D Wexner
{"title":"Umbrella review of systematic reviews on the efficacy and safety of using mesh in the prevention of parastomal hernias.","authors":"Sameh Hany Emile, Justin Dourado, Peter Rogers, Anjelli Wignakumar, Nir Horesh, Zoe Garoufalia, Rachel Gefen, Steven D Wexner","doi":"10.1007/s10029-024-03137-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This umbrella review aimed to summarize the findings and conclusions of published systematic reviews on the prophylactic role of mesh against parastomal hernias in colorectal surgery.</p><p><strong>Methods: </strong>PRISMA-compliant umbrella overview of systematic reviews on the role of mesh in prevention of parastomal hernias was conducted. PubMed and Scopus were searched through November 2023. Main outcomes were efficacy and safety of mesh. Efficacy was assessed by the rates of clinically and radiologically detected hernias and the need for surgical repair, while safety was assessed by the rates of overall complications.</p><p><strong>Results: </strong>19 systematic reviews were assessed; 7 included only patients with end colostomy and 12 included patients with either ileostomy or colostomy. The use of mesh significantly reduced the risk of clinically detected parastomal hernias in all reviews except one. Seven reviews reported a significantly lower risk of radiologically detected parastomal hernias with the use of mesh. The pooled hazards ratio of clinically detected and radiologically detected parastomal hernias was 0.33 (95%CI: 0.26-0.41) and 0.55 (95%CI: 0.45-0.68), respectively. Six reviews reported a significant reduction in the need for surgical repair when a mesh was used whereas six reviews found a similar need for hernia repair. The pooled hazards ratio for surgical hernia repair was 0.46 (95%CI: 0.35-0.62). Eight reviews reported similar complications in the two groups. The pooled hazard ratio of complications was 0.81 (95%CI: 0.66-1).</p><p><strong>Conclusions: </strong>The use of surgical mesh is likely effective and safe in the prevention of parastomal hernias without an increased risk of overall complications.</p>","PeriodicalId":13168,"journal":{"name":"Hernia","volume":" ","pages":"1577-1589"},"PeriodicalIF":2.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11457579/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hernia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10029-024-03137-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/23 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This umbrella review aimed to summarize the findings and conclusions of published systematic reviews on the prophylactic role of mesh against parastomal hernias in colorectal surgery.
Methods: PRISMA-compliant umbrella overview of systematic reviews on the role of mesh in prevention of parastomal hernias was conducted. PubMed and Scopus were searched through November 2023. Main outcomes were efficacy and safety of mesh. Efficacy was assessed by the rates of clinically and radiologically detected hernias and the need for surgical repair, while safety was assessed by the rates of overall complications.
Results: 19 systematic reviews were assessed; 7 included only patients with end colostomy and 12 included patients with either ileostomy or colostomy. The use of mesh significantly reduced the risk of clinically detected parastomal hernias in all reviews except one. Seven reviews reported a significantly lower risk of radiologically detected parastomal hernias with the use of mesh. The pooled hazards ratio of clinically detected and radiologically detected parastomal hernias was 0.33 (95%CI: 0.26-0.41) and 0.55 (95%CI: 0.45-0.68), respectively. Six reviews reported a significant reduction in the need for surgical repair when a mesh was used whereas six reviews found a similar need for hernia repair. The pooled hazards ratio for surgical hernia repair was 0.46 (95%CI: 0.35-0.62). Eight reviews reported similar complications in the two groups. The pooled hazard ratio of complications was 0.81 (95%CI: 0.66-1).
Conclusions: The use of surgical mesh is likely effective and safe in the prevention of parastomal hernias without an increased risk of overall complications.
期刊介绍:
Hernia was founded in 1997 by Jean P. Chevrel with the purpose of promoting clinical studies and basic research as they apply to groin hernias and the abdominal wall . Since that time, a true revolution in the field of hernia studies has transformed the field from a ”simple” disease to one that is very specialized. While the majority of surgeries for primary inguinal and abdominal wall hernia are performed in hospitals worldwide, complex situations such as multi recurrences, complications, abdominal wall reconstructions and others are being studied and treated in specialist centers. As a result, major institutions and societies are creating specific parameters and criteria to better address the complexities of hernia surgery.
Hernia is a journal written by surgeons who have made abdominal wall surgery their specific field of interest, but we will consider publishing content from any surgeon who wishes to improve the science of this field. The Journal aims to ensure that hernia surgery is safer and easier for surgeons as well as patients, and provides a forum to all surgeons in the exchange of new ideas, results, and important research that is the basis of professional activity.