Laura Aguilera Saiz , Wouter J. Heerink , Harald C. Groen , Marijn A.J. Hiep , Henk G. van der Poel , Esther M.K. Wit , Jakko A. Nieuwenhuijzen , Ton A. Roeleveld , André N. Vis , Maarten L. Donswijk , Pim J. van Leeuwen , Theo J.M. Ruers
{"title":"Feasibility of Image-guided Navigation with Electromagnetic Tracking During Robot-assisted Sentinel Node Biopsy: A Prospective Study","authors":"Laura Aguilera Saiz , Wouter J. Heerink , Harald C. Groen , Marijn A.J. Hiep , Henk G. van der Poel , Esther M.K. Wit , Jakko A. Nieuwenhuijzen , Ton A. Roeleveld , André N. Vis , Maarten L. Donswijk , Pim J. van Leeuwen , Theo J.M. Ruers","doi":"10.1016/j.eururo.2024.07.022","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and objective</h3><div>Image-guided surgical navigation (IGSN) can enhance surgical precision and safety. The expansion of minimally invasive surgery has increased the demand for integration of these navigation systems into robot-assisted surgery. Our objective was to evaluate the integration of electromagnetic tracking with IGSN in robot-assisted sentinel lymph node biopsy (SLNB).</div></div><div><h3>Methods</h3><div>We conducted a prospective feasibility study to test the use of IGSN in SLNB. In total, 25 patients scheduled for SLNB at The Netherlands Cancer Institute were included (March 2022 to March 2023). SLNB using IGSN was performed using a standardised technique with a da Vinci robot (Intuitive Surgical, Sunnyvale, CA, USA) in four-arm configuration. Feasibility was determined as the percentage of sentinel nodes (SNs) successfully identified via IGSN. Successful SN resection was defined as SNs correctly localised via navigation and validated ex vivo with a gamma probe. Surgeon feedback on the robot-assisted IGSN workflow was evaluated using the System Usability Scale (SUS).</div></div><div><h3>Key findings and limitations</h3><div>In accordance with the protocol, the first five patients were used for workflow optimisation, and the subsequent 20 patients were included in the analysis. IGSN led to successful identification of 91% (50/55) of the SNs. There were no complications associated with navigation. The surgeon feedback (SUS) was 60.9, with lowest scores reported for the user interface and workflow integration.</div></div><div><h3>Conclusions</h3><div>IGSN during robot-assisted surgery was feasible and safe. The technique allowed identification and removal of predefined small pelvic lymph nodes.</div></div><div><h3>Patient summary</h3><div>We carried out a study on the feasibility of imaging-guided navigation in robot-assisted prostate surgery. Our results show that this technique is feasible, safe, and effective.</div></div>","PeriodicalId":12223,"journal":{"name":"European urology","volume":"87 4","pages":"Pages 482-490"},"PeriodicalIF":25.2000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European urology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0302283824025107","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/22 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and objective
Image-guided surgical navigation (IGSN) can enhance surgical precision and safety. The expansion of minimally invasive surgery has increased the demand for integration of these navigation systems into robot-assisted surgery. Our objective was to evaluate the integration of electromagnetic tracking with IGSN in robot-assisted sentinel lymph node biopsy (SLNB).
Methods
We conducted a prospective feasibility study to test the use of IGSN in SLNB. In total, 25 patients scheduled for SLNB at The Netherlands Cancer Institute were included (March 2022 to March 2023). SLNB using IGSN was performed using a standardised technique with a da Vinci robot (Intuitive Surgical, Sunnyvale, CA, USA) in four-arm configuration. Feasibility was determined as the percentage of sentinel nodes (SNs) successfully identified via IGSN. Successful SN resection was defined as SNs correctly localised via navigation and validated ex vivo with a gamma probe. Surgeon feedback on the robot-assisted IGSN workflow was evaluated using the System Usability Scale (SUS).
Key findings and limitations
In accordance with the protocol, the first five patients were used for workflow optimisation, and the subsequent 20 patients were included in the analysis. IGSN led to successful identification of 91% (50/55) of the SNs. There were no complications associated with navigation. The surgeon feedback (SUS) was 60.9, with lowest scores reported for the user interface and workflow integration.
Conclusions
IGSN during robot-assisted surgery was feasible and safe. The technique allowed identification and removal of predefined small pelvic lymph nodes.
Patient summary
We carried out a study on the feasibility of imaging-guided navigation in robot-assisted prostate surgery. Our results show that this technique is feasible, safe, and effective.
期刊介绍:
European Urology is a peer-reviewed journal that publishes original articles and reviews on a broad spectrum of urological issues. Covering topics such as oncology, impotence, infertility, pediatrics, lithiasis and endourology, the journal also highlights recent advances in techniques, instrumentation, surgery, and pediatric urology. This comprehensive approach provides readers with an in-depth guide to international developments in urology.