Safety and accuracy of stereoelectroencephalography for pediatric and young adult patients with prior craniotomy.

IF 2.1 3区 医学 Q3 CLINICAL NEUROLOGY Journal of neurosurgery. Pediatrics Pub Date : 2024-08-23 DOI:10.3171/2024.6.PEDS24198
Peter H Yang, Nathan Wulfekammer, Amanda V Jenson, Elliot G Neal, Stuart Tomko, John Zempel, Peter Brunner, Sean D McEvoy, Matthew D Smyth, Jarod L Roland
{"title":"Safety and accuracy of stereoelectroencephalography for pediatric and young adult patients with prior craniotomy.","authors":"Peter H Yang, Nathan Wulfekammer, Amanda V Jenson, Elliot G Neal, Stuart Tomko, John Zempel, Peter Brunner, Sean D McEvoy, Matthew D Smyth, Jarod L Roland","doi":"10.3171/2024.6.PEDS24198","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The authors assessed the safety and accuracy of stereoelectroencephalography (SEEG) electrode implantation in pediatric patients who had previously undergone craniotomy compared to those without prior cranial surgery.</p><p><strong>Methods: </strong>The authors performed a retrospective analysis of patients under 25 years of age with medically refractory epilepsy at a single institution who underwent SEEG electrode placement between March 2016 and July 2023. Surgical history and demographic characteristics were collected from the electronic medical records. The coordinates of the anchor bolts and their respective SEEG electrode contacts were manually annotated using postoperative head CT scans. Bolt coordinates were used to calculate the initiated electrode trajectory set by the bolt by using the least-squares method to define a line along the bolt, projected along the length of the electrode. The shortest distance from each electrode contact to this line was calculated to obtain the error measurement. Statistical analysis was conducted using the Kolmogorov-Smirnov test to compare the distribution of errors between groups, the Student t-test was used for continuous variables, and the chi-square/Fisher's exact test was used for categorical variables.</p><p><strong>Results: </strong>Fifty-eight patients underwent a total of 60 SEEG placements and met the inclusion criteria. Eighteen had a history of prior craniotomy and 40 without prior surgery, indicating entirely native cranial bone. Mean age, sex, and mean number of electrodes implanted per surgery were similar between groups. For the electrode contact furthest from the bolt, a mean (IQR) deviation of 1.32 (0.73-2.53) mm was noted for the prior craniotomy group and 1.08 (0.65-1.55) mm for the native bone group (p < 0.0001). A greater number of outliers for the contact furthest from the bolt, defined as > 6 mm from the initiated electrode trajectory, was seen in the prior craniotomy group (p < 0.0001). The complication rate was low and not statistically different between groups.</p><p><strong>Conclusions: </strong>The authors' analysis draws attention to the effect of the intracranial biomechanical environment along the path of the electrode after traversing past the anchor bolt and found that prior craniotomy was associated with a higher number of contacts with a significant deviation from the initiated trajectory. Despite these deviations, we did not find a difference in the overall low complication rate in both groups. Therefore, the authors conclude that SEEG electrode placement is a safe option in pediatric patients even after prior craniotomy.</p>","PeriodicalId":16549,"journal":{"name":"Journal of neurosurgery. Pediatrics","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgery. Pediatrics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3171/2024.6.PEDS24198","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The authors assessed the safety and accuracy of stereoelectroencephalography (SEEG) electrode implantation in pediatric patients who had previously undergone craniotomy compared to those without prior cranial surgery.

Methods: The authors performed a retrospective analysis of patients under 25 years of age with medically refractory epilepsy at a single institution who underwent SEEG electrode placement between March 2016 and July 2023. Surgical history and demographic characteristics were collected from the electronic medical records. The coordinates of the anchor bolts and their respective SEEG electrode contacts were manually annotated using postoperative head CT scans. Bolt coordinates were used to calculate the initiated electrode trajectory set by the bolt by using the least-squares method to define a line along the bolt, projected along the length of the electrode. The shortest distance from each electrode contact to this line was calculated to obtain the error measurement. Statistical analysis was conducted using the Kolmogorov-Smirnov test to compare the distribution of errors between groups, the Student t-test was used for continuous variables, and the chi-square/Fisher's exact test was used for categorical variables.

Results: Fifty-eight patients underwent a total of 60 SEEG placements and met the inclusion criteria. Eighteen had a history of prior craniotomy and 40 without prior surgery, indicating entirely native cranial bone. Mean age, sex, and mean number of electrodes implanted per surgery were similar between groups. For the electrode contact furthest from the bolt, a mean (IQR) deviation of 1.32 (0.73-2.53) mm was noted for the prior craniotomy group and 1.08 (0.65-1.55) mm for the native bone group (p < 0.0001). A greater number of outliers for the contact furthest from the bolt, defined as > 6 mm from the initiated electrode trajectory, was seen in the prior craniotomy group (p < 0.0001). The complication rate was low and not statistically different between groups.

Conclusions: The authors' analysis draws attention to the effect of the intracranial biomechanical environment along the path of the electrode after traversing past the anchor bolt and found that prior craniotomy was associated with a higher number of contacts with a significant deviation from the initiated trajectory. Despite these deviations, we did not find a difference in the overall low complication rate in both groups. Therefore, the authors conclude that SEEG electrode placement is a safe option in pediatric patients even after prior craniotomy.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对曾接受开颅手术的儿童和年轻成人患者进行立体脑电图检查的安全性和准确性。
目的:作者评估了立体脑电图(SEEG)电极植入的安全性和准确性:作者评估了曾接受开颅手术的儿科患者与未接受开颅手术的患者相比,立体脑电图(SEEG)电极植入的安全性和准确性:作者对2016年3月至2023年7月期间在一家医疗机构接受SEEG电极植入术的25岁以下医学难治性癫痫患者进行了回顾性分析。从电子病历中收集了手术史和人口统计学特征。使用术后头部 CT 扫描手动标注锚栓坐标及其各自的 SEEG 电极接触点。螺栓坐标用于计算螺栓设定的初始电极轨迹,方法是使用最小二乘法沿螺栓定义一条线,并沿电极长度投影。计算每个电极触点到这条直线的最短距离,从而获得误差测量值。统计分析采用 Kolmogorov-Smirnov 检验比较组间误差分布,连续变量采用学生 t 检验,分类变量采用卡方/费舍尔精确检验:58 名患者共接受了 60 次 SEEG 放置,均符合纳入标准。其中 18 人曾接受过开颅手术,40 人未接受过手术,这表明他们的颅骨完全是原生的。两组患者的平均年龄、性别和每次手术植入电极的平均数量相似。对于离螺栓最远的电极接触点,开颅手术前组的平均(IQR)偏差为 1.32 (0.73-2.53) mm,而原生骨组的平均(IQR)偏差为 1.08 (0.65-1.55) mm(P < 0.0001)。先前开颅手术组中,距离螺栓最远的接触点(定义为距离初始电极轨迹 > 6 mm)的异常值数量较多(p < 0.0001)。并发症发生率较低,组间无统计学差异:作者的分析提醒人们注意电极穿过锚栓后颅内生物力学环境对电极轨迹的影响,并发现之前进行过开颅手术的患者接触次数较多,且明显偏离初始轨迹。尽管存在这些偏差,但我们并未发现两组在总体低并发症发生率方面存在差异。因此,作者认为 SEEG 电极置入术对儿科患者来说是一种安全的选择,即使之前进行过开颅手术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of neurosurgery. Pediatrics
Journal of neurosurgery. Pediatrics 医学-临床神经学
CiteScore
3.40
自引率
10.50%
发文量
307
审稿时长
2 months
期刊介绍: Information not localiced
期刊最新文献
Pediatric CSF diversion procedures for treatment of hydrocephalus during the COVID-19 pandemic. The impact of spheno-occipital synchondrosis exposure via extended endoscopic endonasal surgery on midface growth in pediatric patients. Association between social determinants of health and select neurosurgical procedures in the National Spina Bifida Patient Registry. Letter to the Editor. Sleep apnea and Chiari malformation type I. Predictors of postsurgical retethering in pediatric fatty or tight filum terminale: a systematic review and meta-analysis of 1167 patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1