Daniel Jaglarz , Jacek Kowalczewski , Piotr Dudek , Rafał Pankowski , Dariusz Marczak , Dariusz Grzelecki
{"title":"The influence of the surgeon’s handedness and standing position at the operating table on the radiological outcomes in primary total knee arthroplasty","authors":"Daniel Jaglarz , Jacek Kowalczewski , Piotr Dudek , Rafał Pankowski , Dariusz Marczak , Dariusz Grzelecki","doi":"10.1016/j.knee.2024.08.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The purpose of this study was to compare radiological outcomes of total knee arthroplasty (TKA) in mechanical alignment implant positioning in the coronal and sagittal planes depending on surgeons’ handedness and their position at the operating table.</p></div><div><h3>Methods</h3><p>A total number of 200 consecutive patients with idiopathic osteoarthritis and varus knees who underwent TKA were retrospectively included in this research. Patients were operated on by 4 surgeons (50 for each surgeon) selected according to their handedness and position at the operative table. Surgeon I (right-handed, standing at the operating table always on the right side); Surgeon II<!--> <!-->(left-handed, standing at the operating table always on the left side); Surgeon III (right-handed, standing at the operating table on the side of the operated limb); Surgeon IV (left-handed, standing at the operating table on the side of the operated limb).</p></div><div><h3>Results</h3><p>Comparing postoperative radiological results statistically significant differences were calculated in the case of deviation from HKA angle (left TKA -1.5°; Interquartile Range [IQR] = -2.6−[-1] vs right TKA -3°; IQR = -4.5−[-2]; p = 0.01) for surgeon II and MPTA for surgeon IV (left TKA 0°; IQR = -1–0.5 vs right TKA 1°; IQR = 0–2; p < 0.01). Higher deviation from the mechanical alignment angles and implant positioning was revealed for a less convenient operation site for the surgeon.</p></div><div><h3>Conclusion</h3><p>We recommend that all surgeons performing TKAs from the less comfortable side should take great care in establishing the MPTA and HKA angles to avoid surgical errors in implant positioning and limb alignment.</p></div>","PeriodicalId":56110,"journal":{"name":"Knee","volume":"50 ","pages":"Pages 147-153"},"PeriodicalIF":1.6000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0968016024001340/pdfft?md5=d3e0fc69d4931c91fe96adac6d1690fc&pid=1-s2.0-S0968016024001340-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0968016024001340","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The purpose of this study was to compare radiological outcomes of total knee arthroplasty (TKA) in mechanical alignment implant positioning in the coronal and sagittal planes depending on surgeons’ handedness and their position at the operating table.
Methods
A total number of 200 consecutive patients with idiopathic osteoarthritis and varus knees who underwent TKA were retrospectively included in this research. Patients were operated on by 4 surgeons (50 for each surgeon) selected according to their handedness and position at the operative table. Surgeon I (right-handed, standing at the operating table always on the right side); Surgeon II (left-handed, standing at the operating table always on the left side); Surgeon III (right-handed, standing at the operating table on the side of the operated limb); Surgeon IV (left-handed, standing at the operating table on the side of the operated limb).
Results
Comparing postoperative radiological results statistically significant differences were calculated in the case of deviation from HKA angle (left TKA -1.5°; Interquartile Range [IQR] = -2.6−[-1] vs right TKA -3°; IQR = -4.5−[-2]; p = 0.01) for surgeon II and MPTA for surgeon IV (left TKA 0°; IQR = -1–0.5 vs right TKA 1°; IQR = 0–2; p < 0.01). Higher deviation from the mechanical alignment angles and implant positioning was revealed for a less convenient operation site for the surgeon.
Conclusion
We recommend that all surgeons performing TKAs from the less comfortable side should take great care in establishing the MPTA and HKA angles to avoid surgical errors in implant positioning and limb alignment.
期刊介绍:
The Knee is an international journal publishing studies on the clinical treatment and fundamental biomechanical characteristics of this joint. The aim of the journal is to provide a vehicle relevant to surgeons, biomedical engineers, imaging specialists, materials scientists, rehabilitation personnel and all those with an interest in the knee.
The topics covered include, but are not limited to:
• Anatomy, physiology, morphology and biochemistry;
• Biomechanical studies;
• Advances in the development of prosthetic, orthotic and augmentation devices;
• Imaging and diagnostic techniques;
• Pathology;
• Trauma;
• Surgery;
• Rehabilitation.