Comparative evaluation of local and downstream responses in two commercially available paclitaxel-coated balloons in healthy peripheral arteries of a swine model

IF 2.3 4区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiovascular Pathology Pub Date : 2024-08-22 DOI:10.1016/j.carpath.2024.107688
{"title":"Comparative evaluation of local and downstream responses in two commercially available paclitaxel-coated balloons in healthy peripheral arteries of a swine model","authors":"","doi":"10.1016/j.carpath.2024.107688","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>To investigate the local, downstream, and systemic effects of 2 different paclitaxel-coated balloons.</p></div><div><h3>Design</h3><p>Preclinical study in healthy peripheral arteries of a swine model, with randomized allocation of the distribution of the devices: the test paclitaxel-coated balloon (PCB) (Luminor<sup>Ⓡ</sup>), a control PCB (IN.PACT<sup>Ⓡ</sup>), and a plain angioplasty balloon (Oceanus<sup>Ⓡ</sup>), considering single (1×) and overlapping (3×) doses with simple blind histologic analysis.</p></div><div><h3>Methods</h3><p>Twenty animals underwent balloon angioplasty at 1× or 3× doses in the external and internal branches of both femoral arteries and were followed-up for 28 days. Postprocedural and follow-up angiography were carried out. Comprehensive necropsy and histology were used to evaluate the local, downstream and systemic effects.</p></div><div><h3>Results</h3><p>Angioplasty was successfully carried out in all animals. Significant protocol deviations appeared in 3 arteries (treated with Oceanus®) without clinical relevance. Those samples were excluded from the analysis. All the animals survived the follow-up period without major clinical issues. Local signs of drug toxicity were less marked with Luminor® than IN.PACT® at 1× dose, including endothelial loss (<em>P</em> = .0828), intima/media inflammation (<em>P = .</em>0004), transmural medial smooth muscle cell (SMC) loss (<em>P = .</em>0016), wall thickness loss (<em>P = .</em>0141), presence of fibrin in the vascular wall (<em>P = .</em>0054), and adventitial inflammation (<em>P = .</em>0080). A similar pattern was observed at the 3× dose for endothelial loss (<em>P = .</em>0011), intima/media inflammation (<em>P</em> &lt; .0001), circumferential SMC loss (<em>P = .</em>0004), medial SMC replacement with proteoglycans (<em>P = .</em>0014), fibrin (<em>P</em> = .0034), and collagen content (<em>P = .</em>0205). Downstream vascular histologic changes were mild although more prevalent in the IN.PACT® 3× group (<em>P</em> = .006). No systemic effects of toxicity were detected in any of the samples analyzed.</p></div><div><h3>Conclusion</h3><p>Luminor® showed better healing pattern (lower inflammation, and endothelial and muscular loss) than IN.PACT® balloon. The effect was evident at single and triple doses. The prevalence of downstream lesions, albeit low, was higher with the triple dose of IN.PACT® compared with Luminor®.</p></div>","PeriodicalId":9451,"journal":{"name":"Cardiovascular Pathology","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S105488072400084X/pdfft?md5=5cc18fef6fc22cd638ff97f9b9e647a6&pid=1-s2.0-S105488072400084X-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Pathology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S105488072400084X","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To investigate the local, downstream, and systemic effects of 2 different paclitaxel-coated balloons.

Design

Preclinical study in healthy peripheral arteries of a swine model, with randomized allocation of the distribution of the devices: the test paclitaxel-coated balloon (PCB) (Luminor), a control PCB (IN.PACT), and a plain angioplasty balloon (Oceanus), considering single (1×) and overlapping (3×) doses with simple blind histologic analysis.

Methods

Twenty animals underwent balloon angioplasty at 1× or 3× doses in the external and internal branches of both femoral arteries and were followed-up for 28 days. Postprocedural and follow-up angiography were carried out. Comprehensive necropsy and histology were used to evaluate the local, downstream and systemic effects.

Results

Angioplasty was successfully carried out in all animals. Significant protocol deviations appeared in 3 arteries (treated with Oceanus®) without clinical relevance. Those samples were excluded from the analysis. All the animals survived the follow-up period without major clinical issues. Local signs of drug toxicity were less marked with Luminor® than IN.PACT® at 1× dose, including endothelial loss (P = .0828), intima/media inflammation (P = .0004), transmural medial smooth muscle cell (SMC) loss (P = .0016), wall thickness loss (P = .0141), presence of fibrin in the vascular wall (P = .0054), and adventitial inflammation (P = .0080). A similar pattern was observed at the 3× dose for endothelial loss (P = .0011), intima/media inflammation (P < .0001), circumferential SMC loss (P = .0004), medial SMC replacement with proteoglycans (P = .0014), fibrin (P = .0034), and collagen content (P = .0205). Downstream vascular histologic changes were mild although more prevalent in the IN.PACT® 3× group (P = .006). No systemic effects of toxicity were detected in any of the samples analyzed.

Conclusion

Luminor® showed better healing pattern (lower inflammation, and endothelial and muscular loss) than IN.PACT® balloon. The effect was evident at single and triple doses. The prevalence of downstream lesions, albeit low, was higher with the triple dose of IN.PACT® compared with Luminor®.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比较评估两种市售紫杉醇涂层球囊在猪健康外周动脉模型中的局部和下游反应。
目的:研究两种不同的紫杉醇涂层球囊对局部、下游和全身的影响:研究两种不同紫杉醇涂层球囊的局部、下游和全身效应:设计:在猪模型的健康外周动脉中进行临床前研究,随机分配设备:试验紫杉醇涂层球囊(PCB)(Luminor®)、对照PCB(IN.PACT®)和普通血管成形球囊(Oceanus®),考虑单一(1×)和重叠(3×)剂量,并进行简单的盲组织学分析:方法:20 只动物接受了双股动脉外支和内支 1× 或 3× 剂量的球囊血管成形术,并随访 28 天。进行术后和随访血管造影。采用全面尸检和组织学方法评估局部、下游和全身影响:结果:所有动物都成功进行了血管成形术。三条动脉(用 Oceanus® 治疗)出现了明显的方案偏差,但无临床意义。这些样本被排除在分析之外。所有动物在随访期间均无重大临床问题。与 IN.PACT® 相比,在使用 1 倍剂量时,Luminor® 的局部药物毒性症状不明显,包括内皮损失(p=0.0828)、内膜/中层炎症(p=0.0004)、跨壁内侧平滑肌细胞(SMC)损失(p=0.0016)、管壁厚度损失(p=0.0141)、血管壁出现纤维蛋白(p=0.0054)和临壁炎症(p=0.0080)。在 3 倍剂量下,也观察到了类似的模式,包括内皮损失(p=0.0011)、内膜/中层炎症(p< 0.0001)、周向 SMC 损失(p=0.0004)、内侧 SMC 被蛋白多糖替代(p=0.0014)、纤维蛋白(p=0.0034)和胶原含量(p=0.0205)。下游血管组织学变化轻微,但在 IN.PACT® 3× 组中更为普遍(p=0.006)。在分析的所有样本中均未检测到系统毒性影响:结论:与 IN.PACT® 球囊相比,Luminor® 显示出更好的愈合模式(较低的炎症、内皮和肌肉损失)。单剂量和三剂量的效果都很明显。与 Luminor® 相比,IN.PACT® 三倍剂量的下游病变发生率虽然较低,但却更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Cardiovascular Pathology
Cardiovascular Pathology 医学-病理学
CiteScore
7.50
自引率
2.70%
发文量
71
审稿时长
18 days
期刊介绍: Cardiovascular Pathology is a bimonthly journal that presents articles on topics covering the entire spectrum of cardiovascular disease. The Journal''s primary objective is to publish papers on disease-oriented morphology and pathogenesis from clinicians and scientists in the cardiovascular field. Subjects covered include cardiovascular biology, prosthetic devices, molecular biology and experimental models of cardiovascular disease.
期刊最新文献
Cause of Death for Heart Transplant Patients, an Autopsy Study. Interplay of atherosclerosis and medial degeneration in human ascending aorta Sudden cardiac death caused by Kawasaki coronary artery vasculitis in a child with Hodgkin's lymphoma. Case report and literature review. Unlocking Vascular Vitality: Exploring the Impact of LIMA Harvesting Technique on Endothelial Health. Sudden infant death syndrome “Gray Zone” in newborn with pneumonia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1