Bernd Zeiss, Eric Offermann, Annick Gillet, Erik Haghedooren, Markus Bischof
{"title":"Prefilled Ophthalmic syringes - New Possibilities in Terminal Sterilization.","authors":"Bernd Zeiss, Eric Offermann, Annick Gillet, Erik Haghedooren, Markus Bischof","doi":"10.5731/pdajpst.2024.012968","DOIUrl":null,"url":null,"abstract":"<p><p>In a joint study carried out by Gerresheimer, Sterigenics and Früh, it could be shown that also NO<sub>2</sub> is well suited to terminally sterilize prefilled ophthalmic syringes. In detail 5 topics were addressed: (1) Compare EtO vs. NO<sub>2</sub> penetration into the filled syringe; (2) Analyze gas ingress though 4 different plunger stoppers including silicone oil free and standard rubber plungers; (3) Scrutinize gas ingress through 2 different cap designs based on different elastomer properties; (4) Investigate gas permeation through COP plastic barrels compared to glass; (5) Check if the Tyvek®-layer has an influence on either sterilization.Depending on the needs a suitable sterilization method, packaging and syringe type can be suggested to customers.</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":"78 4","pages":"532-533"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2024.012968","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
In a joint study carried out by Gerresheimer, Sterigenics and Früh, it could be shown that also NO2 is well suited to terminally sterilize prefilled ophthalmic syringes. In detail 5 topics were addressed: (1) Compare EtO vs. NO2 penetration into the filled syringe; (2) Analyze gas ingress though 4 different plunger stoppers including silicone oil free and standard rubber plungers; (3) Scrutinize gas ingress through 2 different cap designs based on different elastomer properties; (4) Investigate gas permeation through COP plastic barrels compared to glass; (5) Check if the Tyvek®-layer has an influence on either sterilization.Depending on the needs a suitable sterilization method, packaging and syringe type can be suggested to customers.