Characterizing patterns of diffusion tensor imaging variance in aging brains.

IF 1.9 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Medical Imaging Pub Date : 2024-07-01 Epub Date: 2024-08-24 DOI:10.1117/1.JMI.11.4.044007
Chenyu Gao, Qi Yang, Michael E Kim, Nazirah Mohd Khairi, Leon Y Cai, Nancy R Newlin, Praitayini Kanakaraj, Lucas W Remedios, Aravind R Krishnan, Xin Yu, Tianyuan Yao, Panpan Zhang, Kurt G Schilling, Daniel Moyer, Derek B Archer, Susan M Resnick, Bennett A Landman
{"title":"Characterizing patterns of diffusion tensor imaging variance in aging brains.","authors":"Chenyu Gao, Qi Yang, Michael E Kim, Nazirah Mohd Khairi, Leon Y Cai, Nancy R Newlin, Praitayini Kanakaraj, Lucas W Remedios, Aravind R Krishnan, Xin Yu, Tianyuan Yao, Panpan Zhang, Kurt G Schilling, Daniel Moyer, Derek B Archer, Susan M Resnick, Bennett A Landman","doi":"10.1117/1.JMI.11.4.044007","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>As large analyses merge data across sites, a deeper understanding of variance in statistical assessment across the sources of data becomes critical for valid analyses. Diffusion tensor imaging (DTI) exhibits spatially varying and correlated noise, so care must be taken with distributional assumptions. Here, we characterize the role of physiology, subject compliance, and the interaction of the subject with the scanner in the understanding of DTI variability, as modeled in the spatial variance of derived metrics in homogeneous regions.</p><p><strong>Approach: </strong>We analyze DTI data from 1035 subjects in the Baltimore Longitudinal Study of Aging, with ages ranging from 22.4 to 103 years old. For each subject, up to 12 longitudinal sessions were conducted. We assess the variance of DTI scalars within regions of interest (ROIs) defined by four segmentation methods and investigate the relationships between the variance and covariates, including baseline age, time from the baseline (referred to as \"interval\"), motion, sex, and whether it is the first scan or the second scan in the session.</p><p><strong>Results: </strong>Covariate effects are heterogeneous and bilaterally symmetric across ROIs. Inter-session interval is positively related ( <math><mrow><mi>p</mi> <mo>≪</mo> <mn>0.001</mn></mrow> </math> ) to FA variance in the cuneus and occipital gyrus, but negatively ( <math><mrow><mi>p</mi> <mo>≪</mo> <mn>0.001</mn></mrow> </math> ) in the caudate nucleus. Males show significantly ( <math><mrow><mi>p</mi> <mo>≪</mo> <mn>0.001</mn></mrow> </math> ) higher FA variance in the right putamen, thalamus, body of the corpus callosum, and cingulate gyrus. In 62 out of 176 ROIs defined by the Eve type-1 atlas, an increase in motion is associated ( <math><mrow><mi>p</mi> <mo><</mo> <mn>0.05</mn></mrow> </math> ) with a decrease in FA variance. Head motion increases during the rescan of DTI ( <math><mrow><mi>Δ</mi> <mi>μ</mi> <mo>=</mo> <mn>0.045</mn></mrow> </math> mm per volume).</p><p><strong>Conclusions: </strong>The effects of each covariate on DTI variance and their relationships across ROIs are complex. Ultimately, we encourage researchers to include estimates of variance when sharing data and consider models of heteroscedasticity in analysis. This work provides a foundation for study planning to account for regional variations in metric variance.</p>","PeriodicalId":47707,"journal":{"name":"Journal of Medical Imaging","volume":"11 4","pages":"044007"},"PeriodicalIF":1.9000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11344569/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JMI.11.4.044007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: As large analyses merge data across sites, a deeper understanding of variance in statistical assessment across the sources of data becomes critical for valid analyses. Diffusion tensor imaging (DTI) exhibits spatially varying and correlated noise, so care must be taken with distributional assumptions. Here, we characterize the role of physiology, subject compliance, and the interaction of the subject with the scanner in the understanding of DTI variability, as modeled in the spatial variance of derived metrics in homogeneous regions.

Approach: We analyze DTI data from 1035 subjects in the Baltimore Longitudinal Study of Aging, with ages ranging from 22.4 to 103 years old. For each subject, up to 12 longitudinal sessions were conducted. We assess the variance of DTI scalars within regions of interest (ROIs) defined by four segmentation methods and investigate the relationships between the variance and covariates, including baseline age, time from the baseline (referred to as "interval"), motion, sex, and whether it is the first scan or the second scan in the session.

Results: Covariate effects are heterogeneous and bilaterally symmetric across ROIs. Inter-session interval is positively related ( p 0.001 ) to FA variance in the cuneus and occipital gyrus, but negatively ( p 0.001 ) in the caudate nucleus. Males show significantly ( p 0.001 ) higher FA variance in the right putamen, thalamus, body of the corpus callosum, and cingulate gyrus. In 62 out of 176 ROIs defined by the Eve type-1 atlas, an increase in motion is associated ( p < 0.05 ) with a decrease in FA variance. Head motion increases during the rescan of DTI ( Δ μ = 0.045 mm per volume).

Conclusions: The effects of each covariate on DTI variance and their relationships across ROIs are complex. Ultimately, we encourage researchers to include estimates of variance when sharing data and consider models of heteroscedasticity in analysis. This work provides a foundation for study planning to account for regional variations in metric variance.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
老化大脑中弥散张量成像差异模式的特征。
目的:由于大型分析会合并不同地点的数据,因此深入了解不同数据源的统计评估差异对于有效分析至关重要。弥散张量成像(DTI)显示出空间变化和相关噪声,因此必须注意分布假设。在此,我们分析了生理学、受试者顺应性以及受试者与扫描仪之间的相互作用在理解 DTI 变异性中的作用,并以同质区域中衍生指标的空间方差为模型:我们分析了巴尔的摩老龄化纵向研究(Baltimore Longitudinal Study of Aging)中 1035 名受试者的 DTI 数据,这些受试者的年龄从 22.4 岁到 103 岁不等。每个受试者都进行了多达 12 次纵向研究。我们评估了由四种分割方法定义的感兴趣区(ROI)内 DTI 标量的方差,并研究了方差与协变量之间的关系,协变量包括基线年龄、距基线时间(称为 "间隔")、运动、性别以及是第一次扫描还是第二次扫描:在不同的 ROI 中,协变量的影响是异质和双侧对称的。会话间隔与楔回和枕回的FA方差呈正相关(p≪0.001),但与尾状核呈负相关(p≪0.001)。男性的右侧丘脑、丘脑、胼胝体和扣带回的FA方差明显更高(p≪0.001)。在夏娃 1 型图谱定义的 176 个 ROI 中,有 62 个 ROI 的运动增加(P 0.05)与 FA 方差减小相关。在 DTI 重新扫描期间,头部运动会增加(Δ μ = 0.045 mm/体积):结论:各协变量对 DTI 方差的影响及其在各 ROI 之间的关系非常复杂。最终,我们鼓励研究人员在共享数据时加入方差估计值,并在分析中考虑异方差模型。这项工作为研究规划提供了基础,以考虑度量方差的区域差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Medical Imaging
Journal of Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
4.20%
发文量
0
期刊介绍: JMI covers fundamental and translational research, as well as applications, focused on medical imaging, which continue to yield physical and biomedical advancements in the early detection, diagnostics, and therapy of disease as well as in the understanding of normal. The scope of JMI includes: Imaging physics, Tomographic reconstruction algorithms (such as those in CT and MRI), Image processing and deep learning, Computer-aided diagnosis and quantitative image analysis, Visualization and modeling, Picture archiving and communications systems (PACS), Image perception and observer performance, Technology assessment, Ultrasonic imaging, Image-guided procedures, Digital pathology, Biomedical applications of biomedical imaging. JMI allows for the peer-reviewed communication and archiving of scientific developments, translational and clinical applications, reviews, and recommendations for the field.
期刊最新文献
In-silico study of the impact of system design parameters on microcalcification detection in wide-angle digital breast tomosynthesis. Estimation of the absorbed dose in simultaneous digital breast tomosynthesis and mechanical imaging. Breathing motion compensation in chest tomosynthesis: evaluation of the effect on image quality and presence of artifacts. Automated assessment of task-based performance of digital mammography and tomosynthesis systems using an anthropomorphic breast phantom and deep learning-based scoring. Our journey toward implementation of digital breast tomosynthesis in breast cancer screening: the Malmö Breast Tomosynthesis Screening Project.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1