Impact of device variability and protocol differences on kidney function during normothermic machine perfusion: A comparative study using porcine and human kidneys.

IF 2.2 3区 医学 Q3 ENGINEERING, BIOMEDICAL Artificial organs Pub Date : 2024-08-28 DOI:10.1111/aor.14851
Veerle A Lantinga, Asel S Arykbaeva, Nora A Spraakman, Elwin W P Blom, Tobias M Huijink, Dorottya K de Vries, Rutger J Ploeg, Ian P J Alwayn, Henri G D Leuvenink, Cyril Moers, L Leonie van Leeuwen
{"title":"Impact of device variability and protocol differences on kidney function during normothermic machine perfusion: A comparative study using porcine and human kidneys.","authors":"Veerle A Lantinga, Asel S Arykbaeva, Nora A Spraakman, Elwin W P Blom, Tobias M Huijink, Dorottya K de Vries, Rutger J Ploeg, Ian P J Alwayn, Henri G D Leuvenink, Cyril Moers, L Leonie van Leeuwen","doi":"10.1111/aor.14851","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>A growing interest in renal normothermic machine perfusion (NMP) has resulted in more clinically available perfusion devices. While all perfusion systems have the same aim, there are significant differences in their circuits, pumps, sensors, and software. Therefore, our objective was to assess the impact of different perfusion protocols and devices on kidney function and perfusion parameters during NMP.</p><p><strong>Methods: </strong>Porcine kidneys were subjected to 30 min of warm ischemia, 24 h of static cold storage, and subsequently perfused for 6 h using (1) the Kidney Assist (KA) machine with a pressure of 75 mm Hg, (2) the KA device incorporating several adjustments and a pressure of 85 mm Hg (modified KA), or (3) the Perlife (PL) perfusion device (n = 4). Consecutively, discarded human kidneys were perfused using the KA or modified KA (n = 3) protocol.</p><p><strong>Results: </strong>The PL group quickly reached the device's upper flow limit and consequently received a significantly lower pressure compared to the KA groups. The arterial pO<sub>2</sub> was significantly lower in the PL group. Yet, hemoglobin concentration increased over time, and oxygen consumption was significantly higher compared to the KA groups. Fractional sodium excretion was significantly lower in the PL group. Tissue ATP levels, urine production, and creatinine clearance rates did not differ between groups. In human kidneys, the modified KA group showed significantly lower vascular resistance, higher oxygen delivery, and lower levels of lactate in the perfusate compared to the KA group.</p><p><strong>Conclusions: </strong>This study shows that perfusion characteristics and kidney function are significantly influenced by the perfusion protocol and the device and its settings during normothermic machine perfusion and therefore should be interpreted with caution.</p>","PeriodicalId":8450,"journal":{"name":"Artificial organs","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/aor.14851","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: A growing interest in renal normothermic machine perfusion (NMP) has resulted in more clinically available perfusion devices. While all perfusion systems have the same aim, there are significant differences in their circuits, pumps, sensors, and software. Therefore, our objective was to assess the impact of different perfusion protocols and devices on kidney function and perfusion parameters during NMP.

Methods: Porcine kidneys were subjected to 30 min of warm ischemia, 24 h of static cold storage, and subsequently perfused for 6 h using (1) the Kidney Assist (KA) machine with a pressure of 75 mm Hg, (2) the KA device incorporating several adjustments and a pressure of 85 mm Hg (modified KA), or (3) the Perlife (PL) perfusion device (n = 4). Consecutively, discarded human kidneys were perfused using the KA or modified KA (n = 3) protocol.

Results: The PL group quickly reached the device's upper flow limit and consequently received a significantly lower pressure compared to the KA groups. The arterial pO2 was significantly lower in the PL group. Yet, hemoglobin concentration increased over time, and oxygen consumption was significantly higher compared to the KA groups. Fractional sodium excretion was significantly lower in the PL group. Tissue ATP levels, urine production, and creatinine clearance rates did not differ between groups. In human kidneys, the modified KA group showed significantly lower vascular resistance, higher oxygen delivery, and lower levels of lactate in the perfusate compared to the KA group.

Conclusions: This study shows that perfusion characteristics and kidney function are significantly influenced by the perfusion protocol and the device and its settings during normothermic machine perfusion and therefore should be interpreted with caution.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
常温机器灌流期间设备变异性和方案差异对肾功能的影响:使用猪肾和人肾进行的比较研究。
导言:随着人们对肾脏常温机器灌注(NMP)的兴趣与日俱增,临床上出现了更多的灌注设备。虽然所有灌注系统的目的相同,但其电路、泵、传感器和软件却存在很大差异。因此,我们的目标是评估不同的灌注方案和设备对 NMP 期间肾功能和灌注参数的影响:对猪肾脏进行 30 分钟的温缺血和 24 小时的静态冷藏,然后使用(1)压力为 75 毫米汞柱的肾脏辅助(KA)设备、(2)经过多次调整、压力为 85 毫米汞柱的 KA 设备(改良 KA)或(3)Perlife(PL)灌注设备(n = 4)灌注 6 小时。连续使用 KA 或改进型 KA(n = 3)方案对废弃的人类肾脏进行灌注:结果:与 KA 组相比,PL 组很快就达到了设备的流量上限,因此压力明显降低。PL 组的动脉 pO2 明显降低。然而,随着时间的推移,血红蛋白浓度增加,耗氧量明显高于 KA 组。PL 组的钠排泄率明显较低。组织 ATP 水平、尿量和肌酐清除率在各组之间没有差异。在人体肾脏中,与 KA 组相比,改良 KA 组的血管阻力明显降低,氧输送量增加,灌注液中的乳酸水平降低:本研究表明,在常温机器灌注过程中,灌注特征和肾功能受灌注方案、设备及其设置的影响很大,因此应谨慎解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Artificial organs
Artificial organs 工程技术-工程:生物医学
CiteScore
4.30
自引率
12.50%
发文量
303
审稿时长
4-8 weeks
期刊介绍: Artificial Organs is the official peer reviewed journal of The International Federation for Artificial Organs (Members of the Federation are: The American Society for Artificial Internal Organs, The European Society for Artificial Organs, and The Japanese Society for Artificial Organs), The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, The International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation. Artificial Organs publishes original research articles dealing with developments in artificial organs applications and treatment modalities and their clinical applications worldwide. Membership in the Societies listed above is not a prerequisite for publication. Articles are published without charge to the author except for color figures and excess page charges as noted.
期刊最新文献
Improving the hemocompatibility of centrifugal mechanical circulatory support devices at low flow rates. Early left ventricular unloading during extracorporeal membrane oxygenation in cardiogenic shock: A systematic review and meta-analysis. Safety and efficacy of surgical revascularization with percutaneous ventricular assist device for acute myocardial infarction complicated by cardiogenic shock: Japanese national registry study. Evaluation of extra-corporeal membrane oxygenator cannulae in pulsatile and non-pulsatile pediatric mock circuits. Stimulation of the withdrawal reflex in gait training after stroke: A systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1