Rute C. Dias , Ossi Korhonen , Jarkko Ketolainen , Tuomas Ervasti , João A. Lopes
{"title":"The effect of process parameters on a continuous blending process monitored in-line by near-infrared spectroscopy","authors":"Rute C. Dias , Ossi Korhonen , Jarkko Ketolainen , Tuomas Ervasti , João A. Lopes","doi":"10.1016/j.ejps.2024.106890","DOIUrl":null,"url":null,"abstract":"<div><p>The continuous feeding-mixing system ensures the composition uniformity down to the tableting continuous manufacturing line so that a quality end-product is consistently delivered. Near-infrared spectroscopy (NIRS) enables in-line assessment of the blend's critical quality attributes in real-time. In this study, the effect of total feed rate and impeller speed on the continuous blending process monitored in-line by NIRS was examined by principal component analysis (PCA), ANOVA simultaneous component analysis (ASCA) and partial least squares (PLS) regression. Process data were generated by a factorial experimental design with process parameters and a constant formulation comprised of: 30 % (wt/wt) ibuprofen, 67.5 % (wt/wt) microcrystalline cellulose, 2 % (wt/wt) of sodium starch glycolate and 0.5 % (wt/wt) of magnesium stearate. The PCA hinted at the prevalence of impeller speed effect on ibuprofen concentration due to path length variation of the NIR light caused by the fluidized behaviour in the powder blend as a result of high speed ranges (>300 rpm). The ASCA model indicated that while both impeller speed and total feed rate effects were statistically significant (<em>p</em>-value=0.004), the impeller speed was the factor that contributed the most to the spectral variance (55.5 %). The PLS regression model for the ibuprofen content resulted in a RMSECV of 1.3 % (wt/wt) and showed that impeller speed was yet again the factor that exerted the major influence on spectral variance, owing to its wavelength-dependent effect that prevents common pre-processing techniques from eliminating it across the entire NIR range. The best sample presentation to the NIR probe was achieved at low impeller speed ranges (<600 rpm) and low total feed rates (<15 kg/h), such that it enhanced the PLS model ability to predict the ibuprofen concentration in the blend.</p></div>","PeriodicalId":12018,"journal":{"name":"European Journal of Pharmaceutical Sciences","volume":"202 ","pages":"Article 106890"},"PeriodicalIF":4.3000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0928098724002021/pdfft?md5=5dc93940420444163288b80749282807&pid=1-s2.0-S0928098724002021-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Pharmaceutical Sciences","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0928098724002021","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
The continuous feeding-mixing system ensures the composition uniformity down to the tableting continuous manufacturing line so that a quality end-product is consistently delivered. Near-infrared spectroscopy (NIRS) enables in-line assessment of the blend's critical quality attributes in real-time. In this study, the effect of total feed rate and impeller speed on the continuous blending process monitored in-line by NIRS was examined by principal component analysis (PCA), ANOVA simultaneous component analysis (ASCA) and partial least squares (PLS) regression. Process data were generated by a factorial experimental design with process parameters and a constant formulation comprised of: 30 % (wt/wt) ibuprofen, 67.5 % (wt/wt) microcrystalline cellulose, 2 % (wt/wt) of sodium starch glycolate and 0.5 % (wt/wt) of magnesium stearate. The PCA hinted at the prevalence of impeller speed effect on ibuprofen concentration due to path length variation of the NIR light caused by the fluidized behaviour in the powder blend as a result of high speed ranges (>300 rpm). The ASCA model indicated that while both impeller speed and total feed rate effects were statistically significant (p-value=0.004), the impeller speed was the factor that contributed the most to the spectral variance (55.5 %). The PLS regression model for the ibuprofen content resulted in a RMSECV of 1.3 % (wt/wt) and showed that impeller speed was yet again the factor that exerted the major influence on spectral variance, owing to its wavelength-dependent effect that prevents common pre-processing techniques from eliminating it across the entire NIR range. The best sample presentation to the NIR probe was achieved at low impeller speed ranges (<600 rpm) and low total feed rates (<15 kg/h), such that it enhanced the PLS model ability to predict the ibuprofen concentration in the blend.
期刊介绍:
The journal publishes research articles, review articles and scientific commentaries on all aspects of the pharmaceutical sciences with emphasis on conceptual novelty and scientific quality. The Editors welcome articles in this multidisciplinary field, with a focus on topics relevant for drug discovery and development.
More specifically, the Journal publishes reports on medicinal chemistry, pharmacology, drug absorption and metabolism, pharmacokinetics and pharmacodynamics, pharmaceutical and biomedical analysis, drug delivery (including gene delivery), drug targeting, pharmaceutical technology, pharmaceutical biotechnology and clinical drug evaluation. The journal will typically not give priority to manuscripts focusing primarily on organic synthesis, natural products, adaptation of analytical approaches, or discussions pertaining to drug policy making.
Scientific commentaries and review articles are generally by invitation only or by consent of the Editors. Proceedings of scientific meetings may be published as special issues or supplements to the Journal.