Evaluation of X-ray protective goggles in mitigating eye lens radiation exposure during radiopharmaceutical handling and patient care in nuclear medicine.
{"title":"Evaluation of X-ray protective goggles in mitigating eye lens radiation exposure during radiopharmaceutical handling and patient care in nuclear medicine.","authors":"Tomoko Oikawa, Kaori Saito, Keiichi Kurihara, Daisuke Horikawa, Katsuhiko Uruno, Hironori Kajiwara, Shuhei Ohashi, Masatoshi Hotta, Naoyuki Yagi, Hideaki Kitamura, Shinichi Hasegawa, Ryogo Minamimoto","doi":"10.35772/ghm.2024.01023","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study is to estimate eye lens exposure dose when handling radiopharmaceuticals and interacting with patients receiving radiopharmaceuticals, and to verify the usefulness of X-ray protective goggles in mitigating such radiation exposure using phantoms. To evaluate radiation exposure during the handling of radiopharmaceuticals, we employed a fluorescent glass dosimeter to measure the radiation doses associated with <sup>99m</sup>Tc, <sup>123</sup>I, <sup>131</sup>I, <sup>111</sup>In, and <sup>18</sup>F at distances of 30 cm and 60 cm, followed by calculation of the 3 mm dose equivalent rate (3DER). We then estimated the dose reduction rates for various scenarios, including the use of syringe shields and X-ray protective goggles with lead equivalences of 0.07, 0.15, 0.75, and 0.88 mmPb, as well as their combined application. X-ray protective goggles with lead equivalence of 0.75 mmPb outperformed those with 0.07 mmPb and 0.15 mmPb, for all radionuclides and at both source distances. X-ray protective goggles with 0.88 mmPb outperformed those with 0.75 mmPb during handling of <sup>131</sup>I and <sup>111</sup>In at a distance of 30 cm. In the remaining scenarios, X-ray protective goggles with 0.88 mmPb resulted in marginal reductions or no discernible additional effects. The overall shielding effect of X-ray protective goggles was less pronounced for 131I and 18F, but the combined use of a syringe shield with X-ray protective goggles with 0.75 or 0.88 mmPb improved the dose reduction rate for all scenarios. In simulating patient care, X-ray protective goggles with 0.88 mmPb demonstrated a dose reduction effect of approximately 50% or more. X-ray protective goggles could reduce the 3DER for the eye lens, and were more effective when combined with a syringe shield. It is valid to use a lead equivalence of 0.88 mmPb to fully harness the protective capabilities of X-ray shielding goggles when dealing with all five types of nuclides in clinical settings.</p>","PeriodicalId":12556,"journal":{"name":"Global health & medicine","volume":"6 4","pages":"244-250"},"PeriodicalIF":1.9000,"publicationDate":"2024-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11350357/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global health & medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35772/ghm.2024.01023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of this study is to estimate eye lens exposure dose when handling radiopharmaceuticals and interacting with patients receiving radiopharmaceuticals, and to verify the usefulness of X-ray protective goggles in mitigating such radiation exposure using phantoms. To evaluate radiation exposure during the handling of radiopharmaceuticals, we employed a fluorescent glass dosimeter to measure the radiation doses associated with 99mTc, 123I, 131I, 111In, and 18F at distances of 30 cm and 60 cm, followed by calculation of the 3 mm dose equivalent rate (3DER). We then estimated the dose reduction rates for various scenarios, including the use of syringe shields and X-ray protective goggles with lead equivalences of 0.07, 0.15, 0.75, and 0.88 mmPb, as well as their combined application. X-ray protective goggles with lead equivalence of 0.75 mmPb outperformed those with 0.07 mmPb and 0.15 mmPb, for all radionuclides and at both source distances. X-ray protective goggles with 0.88 mmPb outperformed those with 0.75 mmPb during handling of 131I and 111In at a distance of 30 cm. In the remaining scenarios, X-ray protective goggles with 0.88 mmPb resulted in marginal reductions or no discernible additional effects. The overall shielding effect of X-ray protective goggles was less pronounced for 131I and 18F, but the combined use of a syringe shield with X-ray protective goggles with 0.75 or 0.88 mmPb improved the dose reduction rate for all scenarios. In simulating patient care, X-ray protective goggles with 0.88 mmPb demonstrated a dose reduction effect of approximately 50% or more. X-ray protective goggles could reduce the 3DER for the eye lens, and were more effective when combined with a syringe shield. It is valid to use a lead equivalence of 0.88 mmPb to fully harness the protective capabilities of X-ray shielding goggles when dealing with all five types of nuclides in clinical settings.