{"title":"<i>In vivo</i> electrical properties of the healthy liver and the hepatic tumor in a mouse model between 1 Hz and 1 MHz during a thermal treatment.","authors":"Yitong Guo, Weice Wang, Weichen Li, Junyao Li, Mingxu Zhu, Ruteng Song, Wenjing Zhu, Lei Wang, Zhenyu Ji, Xuetao Shi","doi":"10.1080/02656736.2024.2396122","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> Understansding the changing patterns of <i>in vivo</i> electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of <i>in vivo</i> electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C.</p><p><p><b>Methods and materials:</b> The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ <i>in vivo</i>. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple.</p><p><p><b>Results:</b> The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R<sup>2</sup> > 0.9 for livers and R<sup>2</sup> > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (<i>p</i> < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C.</p><p><p><b>Conclusion:</b> We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.</p>","PeriodicalId":14137,"journal":{"name":"International Journal of Hyperthermia","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Hyperthermia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02656736.2024.2396122","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Understansding the changing patterns of in vivo electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of in vivo electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C.

Methods and materials: The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ in vivo. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple.

Results: The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R2 > 0.9 for livers and R2 > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (p < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C.

Conclusion: We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在热处理过程中,健康肝脏和肝肿瘤小鼠模型在 1 赫兹和 1 兆赫之间的体内电特性。
目的:了解目标组织体内电特性的变化规律对于准确监测温度和热疗疗效至关重要。我们的研究旨在研究小鼠模型中健康肝脏和肝脏肿瘤在 30 °C 至 90 °C 温度下,在 1 Hz 至 1 MHz 频率范围内体内电特性的变化规律和可逆性:麻醉小鼠并暴露靶器官。采用波长为 808 纳米的近红外激光作为加热源,对体内器官进行加热。利用连接阻抗分析仪的四针电极获得不同温度下的阻抗,并通过热电偶进行监测:结果:研究结果表明,随着温度的升高,阻抗逐渐下降。此外,阻抗被归一化为 30 °C 时的阻抗,归一化阻抗的实部被定义为 k 值,范围在 0 至 1 之间。结果表明,k 值与温度呈线性相关(肝脏的 R2 > 0.9,肿瘤的 R2 > 0.8)。在 1、10 和 50 kHz 频率下,肝脏和肿瘤之间存在显著差异(p):我们相信,这些结果将有助于射频消融系统的进步和肝脏热处理期间温度监测技术的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.90
自引率
12.90%
发文量
153
审稿时长
6-12 weeks
期刊介绍: The International Journal of Hyperthermia
期刊最新文献
Therapeutic effects of focused ultrasound on vulvar squamous intraepithelial lesions in rat. Evaluation of the therapeutic efficacy of high-intensity focused ultrasound ablation combined with different drugs in the treatment of adenomyosis Heat shock protein-related diagnostic signature and molecular subtypes in ankylosing spondylitis: new pathogenesis insights Hyperthermia and cisplatin combination therapy promotes caspase-8 accumulation and activation to enhance apoptosis and pyroptosis in cancer cells Intravoxel incoherent motion (IVIM)-derived perfusion fraction mapping for the visual evaluation of MR-guided high intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1