Mustafa A Altaha, Shawn Bailey, Sebastian Mafeld, Arash Jaberi, Kong Teng Tan
{"title":"Axillary compared to brachial access for endovascular procedures.","authors":"Mustafa A Altaha, Shawn Bailey, Sebastian Mafeld, Arash Jaberi, Kong Teng Tan","doi":"10.1177/17085381241279142","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Limited knowledge exists regarding access site complication rates between trans-axillary and trans-brachial approaches with sheath sizes ≥6Fr. We retrospectively reviewed our institution experience with access site complications for percutaneous trans-axillary and trans-brachial arterial interventions using sheath sizes ranging from 6Fr to 10Fr.</p><p><strong>Methods: </strong>We examined 67 endovascular interventions performed over 18 months, restricted to sheath sizes of 6Fr to 10Fr. Procedures utilizing trans-brachial (41 cases) and trans-axillary (26 cases) approaches under sonographic guidance were included. Cases involving hemodialysis accesses and those requiring surgical cut-down were excluded. The primary outcome measure was the occurrence of major access site complications (SIR grade-II/III) within 30 days, with data collected on hemostasis method, sheath size, and complications. Statistical analysis involved ANCOVA and Fisher's exact tests, with significance set at <i>p</i> < .05.</p><p><strong>Results: </strong>Successful percutaneous arterial access was achieved in all cases using either approach (trans-axillary or trans-brachial). Closure devices were employed in all axillary punctures and in 71% of brachial punctures. Major access site complications occurred in 7 out of 41 cases (17%) in the trans-brachial group and in 4 out of 26 cases (15%) in the trans-axillary group. However, there was no statistically significant difference in complication rates between the two groups, regardless of access site or sheath size.</p><p><strong>Conclusion: </strong>Trans-axillary access serves as a safe and effective upper limb access method for percutaneous endovascular procedures requiring sheath size of 7Fr or larger when compared to trans-brachial approach.</p>","PeriodicalId":23549,"journal":{"name":"Vascular","volume":" ","pages":"17085381241279142"},"PeriodicalIF":1.0000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17085381241279142","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Limited knowledge exists regarding access site complication rates between trans-axillary and trans-brachial approaches with sheath sizes ≥6Fr. We retrospectively reviewed our institution experience with access site complications for percutaneous trans-axillary and trans-brachial arterial interventions using sheath sizes ranging from 6Fr to 10Fr.
Methods: We examined 67 endovascular interventions performed over 18 months, restricted to sheath sizes of 6Fr to 10Fr. Procedures utilizing trans-brachial (41 cases) and trans-axillary (26 cases) approaches under sonographic guidance were included. Cases involving hemodialysis accesses and those requiring surgical cut-down were excluded. The primary outcome measure was the occurrence of major access site complications (SIR grade-II/III) within 30 days, with data collected on hemostasis method, sheath size, and complications. Statistical analysis involved ANCOVA and Fisher's exact tests, with significance set at p < .05.
Results: Successful percutaneous arterial access was achieved in all cases using either approach (trans-axillary or trans-brachial). Closure devices were employed in all axillary punctures and in 71% of brachial punctures. Major access site complications occurred in 7 out of 41 cases (17%) in the trans-brachial group and in 4 out of 26 cases (15%) in the trans-axillary group. However, there was no statistically significant difference in complication rates between the two groups, regardless of access site or sheath size.
Conclusion: Trans-axillary access serves as a safe and effective upper limb access method for percutaneous endovascular procedures requiring sheath size of 7Fr or larger when compared to trans-brachial approach.
期刊介绍:
Vascular provides readers with new and unusual up-to-date articles and case reports focusing on vascular and endovascular topics. It is a highly international forum for the discussion and debate of all aspects of this distinct surgical specialty. It also features opinion pieces, literature reviews and controversial issues presented from various points of view.