Ida Arentz Taraldsen MD, Rasmus Mogelvang MD, PhD, Frederik Fasth Grund MD, PhD, Christian Hassager MD, DMSc, Peter Søgaard MD, DMSc, Charlotte Burup Kristensen MD, PhD
{"title":"Increased preload and echocardiographic assessment of diastolic function","authors":"Ida Arentz Taraldsen MD, Rasmus Mogelvang MD, PhD, Frederik Fasth Grund MD, PhD, Christian Hassager MD, DMSc, Peter Søgaard MD, DMSc, Charlotte Burup Kristensen MD, PhD","doi":"10.1111/echo.15917","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Aims</h3>\n \n <p>Echocardiographic diastolic parameters are used to diagnose and monitor increased left ventricular filling pressure (LVFP) and we hypothesized that increased loading conditions cause increased E/e′. Our aim was to assess the effect of preload augmentation on diastolic parameters among both healthy subjects and subjects with known cardiac disease.</p>\n </section>\n \n <section>\n \n <h3> Methods and results</h3>\n \n <p>We included 129 subjects merged from two cohorts; one dialysis cohort (<i>n</i> = 47) and one infusion cohort (<i>n</i> = 82). Echocardiography was performed immediately before and after hemodialysis (HD) or saline infusion, under low and high loading conditions. Elevated LVFP was defined as septal E/e′ ≥ 15 and/or lateral E/e′ ≥ 13 at high-loading conditions. The population was divided according to elevated LVFP (<i>n</i> = 31) and normal LVFP (<i>n</i> = 98). The load difference for the population was 972 ± 460 mL, with no differences in load difference between elevated and normal LVFP (<i>p NS</i>). The subjects with elevated LVFP were older (63 ± 11 vs. 46 ± 16 years, <i>p <</i> .001), and had lower LV ejection fraction (50 ± 14 vs. 59 ± 8.1%, <i>p <</i> .01). After augmented preload, EDV increased in the normal LVFP group (<i>p <</i> .01) but remained unchanged in the elevated LVFP group (<i>p NS</i>). Both E and e′ increased among the subjects with normal LVFP, whereas E/e′ remained unchanged (∆E/e′ +.1 [-.5–1.2]), <i>p NS</i>). Among the subjects with elevated, LVFP we observed increased E but not e′, resulting in significantly increased E/e′ (∆ average E/e′ +2.4 [0–4.0], <i>p</i> <i><</i> .01).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Augmented preload does not seem to affect E/e′ among subjects with normal LVFP, whereas E/e′ seems to increase significantly among subjects with elevated LVFP.</p>\n </section>\n </div>","PeriodicalId":50558,"journal":{"name":"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques","volume":"41 9","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/echo.15917","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/echo.15917","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Aims
Echocardiographic diastolic parameters are used to diagnose and monitor increased left ventricular filling pressure (LVFP) and we hypothesized that increased loading conditions cause increased E/e′. Our aim was to assess the effect of preload augmentation on diastolic parameters among both healthy subjects and subjects with known cardiac disease.
Methods and results
We included 129 subjects merged from two cohorts; one dialysis cohort (n = 47) and one infusion cohort (n = 82). Echocardiography was performed immediately before and after hemodialysis (HD) or saline infusion, under low and high loading conditions. Elevated LVFP was defined as septal E/e′ ≥ 15 and/or lateral E/e′ ≥ 13 at high-loading conditions. The population was divided according to elevated LVFP (n = 31) and normal LVFP (n = 98). The load difference for the population was 972 ± 460 mL, with no differences in load difference between elevated and normal LVFP (p NS). The subjects with elevated LVFP were older (63 ± 11 vs. 46 ± 16 years, p < .001), and had lower LV ejection fraction (50 ± 14 vs. 59 ± 8.1%, p < .01). After augmented preload, EDV increased in the normal LVFP group (p < .01) but remained unchanged in the elevated LVFP group (p NS). Both E and e′ increased among the subjects with normal LVFP, whereas E/e′ remained unchanged (∆E/e′ +.1 [-.5–1.2]), p NS). Among the subjects with elevated, LVFP we observed increased E but not e′, resulting in significantly increased E/e′ (∆ average E/e′ +2.4 [0–4.0], p< .01).
Conclusion
Augmented preload does not seem to affect E/e′ among subjects with normal LVFP, whereas E/e′ seems to increase significantly among subjects with elevated LVFP.
期刊介绍:
Echocardiography: A Journal of Cardiovascular Ultrasound and Allied Techniques is the official publication of the International Society of Cardiovascular Ultrasound. Widely recognized for its comprehensive peer-reviewed articles, case studies, original research, and reviews by international authors. Echocardiography keeps its readership of echocardiographers, ultrasound specialists, and cardiologists well informed of the latest developments in the field.