Research on live detection technology of distribution network cable insulation deterioration state based on harmonic components

IF 2 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Iet Generation Transmission & Distribution Pub Date : 2024-08-16 DOI:10.1049/gtd2.13238
Ran Hu, Haisong Xu, Xu Lu, Anzhe Wang, Zhifeng Xu, Yuli Wang, Daning Zhang
{"title":"Research on live detection technology of distribution network cable insulation deterioration state based on harmonic components","authors":"Ran Hu,&nbsp;Haisong Xu,&nbsp;Xu Lu,&nbsp;Anzhe Wang,&nbsp;Zhifeng Xu,&nbsp;Yuli Wang,&nbsp;Daning Zhang","doi":"10.1049/gtd2.13238","DOIUrl":null,"url":null,"abstract":"<p>Due to the limitations imposed by urban power grid outages for maintenance, on-line harmonic current detection technology for distribution network cables is expected to become an effective supplement to traditional offline diagnostic methods, enhancing the real-time diagnosis of distribution network cable insulation conditions. This study established a 10 kV distribution network cable test platform and prepared typical defective cables subjected to moisture and long-term thermal aging. Using COMSOL finite element electromagnetic simulation, the magnetic flux evolution laws of the cable insulation under typical defects were obtained. Experimental tests provided the harmonic current characteristics and statistical features of cables with typical defects. Based on these data, a method for analysing the degradation degree of distribution network cables was constructed using least absolute shrinkage and selection operator (LASSO) regression analysis. Furthermore, a defect-type identification method based on cluster analysis was proposed. Results indicate that the odd harmonics and the 4th harmonic of the distribution network cable's harmonic current are closely related to the cable's degradation state. A model integrating principal component analysis (PCA) data dimensionality reduction and expectation-maximization clustering analysis achieved a recognition accuracy of up to 75.64% in distinguishing between moisture-affected and normal cable states. The proposed on-line detection and evaluation methods can effectively identify high-risk cables with latent defects.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13238","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13238","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Due to the limitations imposed by urban power grid outages for maintenance, on-line harmonic current detection technology for distribution network cables is expected to become an effective supplement to traditional offline diagnostic methods, enhancing the real-time diagnosis of distribution network cable insulation conditions. This study established a 10 kV distribution network cable test platform and prepared typical defective cables subjected to moisture and long-term thermal aging. Using COMSOL finite element electromagnetic simulation, the magnetic flux evolution laws of the cable insulation under typical defects were obtained. Experimental tests provided the harmonic current characteristics and statistical features of cables with typical defects. Based on these data, a method for analysing the degradation degree of distribution network cables was constructed using least absolute shrinkage and selection operator (LASSO) regression analysis. Furthermore, a defect-type identification method based on cluster analysis was proposed. Results indicate that the odd harmonics and the 4th harmonic of the distribution network cable's harmonic current are closely related to the cable's degradation state. A model integrating principal component analysis (PCA) data dimensionality reduction and expectation-maximization clustering analysis achieved a recognition accuracy of up to 75.64% in distinguishing between moisture-affected and normal cable states. The proposed on-line detection and evaluation methods can effectively identify high-risk cables with latent defects.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于谐波成分的配电网电缆绝缘劣化状态带电检测技术研究
由于城市电网停电检修的限制,配网电缆谐波电流在线检测技术有望成为传统离线诊断方法的有效补充,提高配网电缆绝缘状况的实时诊断能力。本研究建立了 10 kV 配电网电缆测试平台,并制备了受潮和长期热老化的典型缺陷电缆。利用 COMSOL 有限元电磁仿真,获得了典型缺陷下电缆绝缘的磁通演化规律。实验测试提供了具有典型缺陷的电缆的谐波电流特性和统计特征。在这些数据的基础上,利用最小绝对收缩和选择算子(LASSO)回归分析,构建了配电网电缆劣化程度的分析方法。此外,还提出了一种基于聚类分析的缺陷类型识别方法。结果表明,配电网电缆谐波电流的奇次谐波和 4 次谐波与电缆的劣化状态密切相关。主成分分析(PCA)数据降维与期望最大化聚类分析相结合的模型在区分受潮电缆和正常电缆状态方面的识别准确率高达 75.64%。所提出的在线检测和评估方法可有效识别存在潜在缺陷的高风险电缆。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iet Generation Transmission & Distribution
Iet Generation Transmission & Distribution 工程技术-工程:电子与电气
CiteScore
6.10
自引率
12.00%
发文量
301
审稿时长
5.4 months
期刊介绍: IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix. The scope of IET Generation, Transmission & Distribution includes the following: Design of transmission and distribution systems Operation and control of power generation Power system management, planning and economics Power system operation, protection and control Power system measurement and modelling Computer applications and computational intelligence in power flexible AC or DC transmission systems Special Issues. Current Call for papers: Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf
期刊最新文献
Front Cover: Disturbance observer-based finite-time control of a photovoltaic-battery hybrid power system Security constrained optimal power shutoff for wildfire risk mitigation Disturbance observer-based finite-time control of a photovoltaic-battery hybrid power system Multi-agent reinforcement learning in a new transactive energy mechanism Optimized operation of integrated electricity-HCNG systems with distributed hydrogen injecting
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1