Clinton van der Westhuizen, Mae Newton-Foot, Pieter Nel
{"title":"Performance comparison of three commercial multiplex molecular panels for respiratory viruses at a South African academic hospital.","authors":"Clinton van der Westhuizen, Mae Newton-Foot, Pieter Nel","doi":"10.4102/ajlm.v13i1.2415","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Respiratory infections are a major contributor to hospital admissions. Identification of respiratory pathogens by means of conventional culture and serology methods remains challenging. Multiplex molecular assays are an appealing alternative that endeavours to be rapid, more accurate and less arduous.</p><p><strong>Objective: </strong>The study aimed to compare the clinical performance of three commercial multiplex molecular assays for respiratory viruses.</p><p><strong>Methods: </strong>Forty-eight respiratory specimens obtained from patients at Tygerberg Hospital in the Western Cape province of South Africa were studied. These specimens were collected between May 2020 and August 2020. The results of the Seegene Anyplex™ II RV16, FilmArray<sup>®</sup> Respiratory 2.1 <i>plus</i> Panel (FARP), and QIAstat-Dx<sup>®</sup> Respiratory SARS-CoV-2 Panel (QRP) were analysed based on the overlapping targets. A composite reference standard was applied to provide a standard reference for comparison.</p><p><strong>Results: </strong>The overall sensitivity of the Seegene Anyplex™ II RV16 was 96.6% (57/59), the FARP 98.2% (56/57) and the QRP 80.7% (46/57). The overall specificities were 99.8% (660/661), 99.0% (704/711) and 99.7% (709/711), respectively. The QRP failed to detect coronaviruses and parainfluenza viruses in 41.7% (5/12) and 28.6% (4/14) of positive specimens, respectively, while the FARP produced the lowest target specificity of 88.4% (38/43) for rhinovirus/enterovirus.</p><p><strong>Conclusion: </strong>The overall specificity of all three platforms was comparable; however, the sensitivity of the QRP was inferior to that of the ARV and FARP.</p><p><strong>What this study adds: </strong>This study adds to the body of performance characteristics described for respiratory multiplex panels, especially in the African context where molecular diagnostics for infectious diseases are gaining momentum.</p>","PeriodicalId":45412,"journal":{"name":"African Journal of Laboratory Medicine","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11369576/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/ajlm.v13i1.2415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Respiratory infections are a major contributor to hospital admissions. Identification of respiratory pathogens by means of conventional culture and serology methods remains challenging. Multiplex molecular assays are an appealing alternative that endeavours to be rapid, more accurate and less arduous.
Objective: The study aimed to compare the clinical performance of three commercial multiplex molecular assays for respiratory viruses.
Methods: Forty-eight respiratory specimens obtained from patients at Tygerberg Hospital in the Western Cape province of South Africa were studied. These specimens were collected between May 2020 and August 2020. The results of the Seegene Anyplex™ II RV16, FilmArray® Respiratory 2.1 plus Panel (FARP), and QIAstat-Dx® Respiratory SARS-CoV-2 Panel (QRP) were analysed based on the overlapping targets. A composite reference standard was applied to provide a standard reference for comparison.
Results: The overall sensitivity of the Seegene Anyplex™ II RV16 was 96.6% (57/59), the FARP 98.2% (56/57) and the QRP 80.7% (46/57). The overall specificities were 99.8% (660/661), 99.0% (704/711) and 99.7% (709/711), respectively. The QRP failed to detect coronaviruses and parainfluenza viruses in 41.7% (5/12) and 28.6% (4/14) of positive specimens, respectively, while the FARP produced the lowest target specificity of 88.4% (38/43) for rhinovirus/enterovirus.
Conclusion: The overall specificity of all three platforms was comparable; however, the sensitivity of the QRP was inferior to that of the ARV and FARP.
What this study adds: This study adds to the body of performance characteristics described for respiratory multiplex panels, especially in the African context where molecular diagnostics for infectious diseases are gaining momentum.
期刊介绍:
The African Journal of Laboratory Medicine, the official journal of ASLM, focuses on the role of the laboratory and its professionals in the clinical and public healthcare sectors,and is specifically based on an African frame of reference. Emphasis is on all aspects that promote and contribute to the laboratory medicine practices of Africa. This includes, amongst others: laboratories, biomedical scientists and clinicians, medical community, public health officials and policy makers, laboratory systems and policies (translation of laboratory knowledge, practices and technologies in clinical care), interfaces of laboratory with medical science, laboratory-based epidemiology, laboratory investigations, evidence-based effectiveness in real world (actual) settings.