{"title":"Comparison of 1- and 3-piece directly 3-dimensional printed indirect bonding trays: An in vitro study","authors":"Merve Nur Eglenen , Gülden Karabiber","doi":"10.1016/j.ajodo.2024.07.015","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>This study aimed to compare the transfer accuracy of indirect bonding trays of different thicknesses and numbers of pieces.</div></div><div><h3>Methods</h3><div>Digital indirect bonding was performed on 56 printed resin models, divided into 4 groups with 14 models in each: 1-mm 1-piece tray (OPT), 2-mm OPT, 1-mm 3-piece tray (TPT), and 2-mm TPT. The trays were designed using Appliance Designer (3Shape A/S, Copenhagen, Denmark). Angular (torque, tip, or angulation) and linear (mesiodistal, buccolingual, occlusogingival, or vertical) differences were compared by using open-source GOM Inspect software (GOM GmbH, Braunschweig, Germany).</div></div><div><h3>Results</h3><div>In the buccolingual direction, the 1-mm TPT (0.180 ± 0.041 mm) was significantly more accurate than the 1-mm OPT (0.240 ± 0.032 mm). In the vertical direction, significant differences were seen between the 1-mm and 2-mm OPTs (1-mm OPT: 0.220 ± 0.043 mm; 2-mm OPT: 0.428 ± 0.143 mm; <em>P</em> = 0.003) and between the 1-mm and 2-mm TPTs (1-mm TPT: 0.210 ± 0.072 mm; 2-mm TPT: 0.340 ± 0.062 mm; <em>P</em> = 0.004) in the total region. In the tip angle, significant differences were seen between the 1-mm and 2-mm OPTs and between the 1-mm OPT and TPT. In the torque angle, a significant difference was seen between the 1-mm TPT <span><math><mrow><mrow><mo>(</mo><mrow><mn>2.815</mn><mo>°</mo></mrow><mspace></mspace><mo>±</mo><mspace></mspace><mrow><mn>0.350</mn><mo>°</mo></mrow><mo>)</mo></mrow><mspace></mspace><mtext>and 2-mm</mtext><mspace></mspace><mtext>TP</mtext><mi>T</mi></mrow></math></span> (2.368° ± 0.245°; <em>P</em> = 0.017).</div></div><div><h3>Conclusions</h3><div>Both the thickness and the splitting of the trays impacted the bracket bonding accuracy. The 1-mm trays were more accurate than the 2-mm trays. Despite a few statistically significant differences between the 1-mm OPT and TPT, the 1-mm OPT was recommended for clinical use, considering the designing and placing of the trays.</div></div>","PeriodicalId":50806,"journal":{"name":"American Journal of Orthodontics and Dentofacial Orthopedics","volume":"166 6","pages":"Pages 524-537"},"PeriodicalIF":2.7000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Orthodontics and Dentofacial Orthopedics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0889540624002932","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
This study aimed to compare the transfer accuracy of indirect bonding trays of different thicknesses and numbers of pieces.
Methods
Digital indirect bonding was performed on 56 printed resin models, divided into 4 groups with 14 models in each: 1-mm 1-piece tray (OPT), 2-mm OPT, 1-mm 3-piece tray (TPT), and 2-mm TPT. The trays were designed using Appliance Designer (3Shape A/S, Copenhagen, Denmark). Angular (torque, tip, or angulation) and linear (mesiodistal, buccolingual, occlusogingival, or vertical) differences were compared by using open-source GOM Inspect software (GOM GmbH, Braunschweig, Germany).
Results
In the buccolingual direction, the 1-mm TPT (0.180 ± 0.041 mm) was significantly more accurate than the 1-mm OPT (0.240 ± 0.032 mm). In the vertical direction, significant differences were seen between the 1-mm and 2-mm OPTs (1-mm OPT: 0.220 ± 0.043 mm; 2-mm OPT: 0.428 ± 0.143 mm; P = 0.003) and between the 1-mm and 2-mm TPTs (1-mm TPT: 0.210 ± 0.072 mm; 2-mm TPT: 0.340 ± 0.062 mm; P = 0.004) in the total region. In the tip angle, significant differences were seen between the 1-mm and 2-mm OPTs and between the 1-mm OPT and TPT. In the torque angle, a significant difference was seen between the 1-mm TPT (2.368° ± 0.245°; P = 0.017).
Conclusions
Both the thickness and the splitting of the trays impacted the bracket bonding accuracy. The 1-mm trays were more accurate than the 2-mm trays. Despite a few statistically significant differences between the 1-mm OPT and TPT, the 1-mm OPT was recommended for clinical use, considering the designing and placing of the trays.
期刊介绍:
Published for more than 100 years, the American Journal of Orthodontics and Dentofacial Orthopedics remains the leading orthodontic resource. It is the official publication of the American Association of Orthodontists, its constituent societies, the American Board of Orthodontics, and the College of Diplomates of the American Board of Orthodontics. Each month its readers have access to original peer-reviewed articles that examine all phases of orthodontic treatment. Illustrated throughout, the publication includes tables, color photographs, and statistical data. Coverage includes successful diagnostic procedures, imaging techniques, bracket and archwire materials, extraction and impaction concerns, orthognathic surgery, TMJ disorders, removable appliances, and adult therapy.