Diagnostic accuracy of airway ultrasound in confirming the endotracheal tube depth in critically ill children

IF 2.7 3区 医学 Q1 EMERGENCY MEDICINE American Journal of Emergency Medicine Pub Date : 2024-08-14 DOI:10.1016/j.ajem.2024.08.012
{"title":"Diagnostic accuracy of airway ultrasound in confirming the endotracheal tube depth in critically ill children","authors":"","doi":"10.1016/j.ajem.2024.08.012","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Chest X-ray, the established standard of confirming endotracheal tube (ETT) position, has important drawbacks including radiation exposure. Point-of-care airway ultrasound, which has been insufficiently studied in children, can overcome these problems.</p></div><div><h3>Materials and methods</h3><p>This was a prospective cross-sectional study done on children aged 2 months to 17 years undergoing intubation with cuffed ETT in the PICU. The ETT cuff was filled with saline and three ultrasonographic techniques were used– <em>1)</em> Suprasternal (SS) method <em>2)</em> Cricoid (CC) metho and <em>3)</em> Tracheal ring (TR) method. Position of the ETT as determined by ultrasound and X-ray were compared. The main outcomes were sensitivity, specificity, and area under curve (AUC) for ultrasound-based methods vs. X-ray. For the TR method, concordance between the X-ray and ultrasound categories were taken.</p></div><div><h3>Results</h3><p>Total 62 patients were enrolled. The sensitivity and specificity of SS method were 71% (95% CI: 57–83%) and 100% (40–100%). The CC distance method had an AUC of 0.94 (95% CI: 0.86, 1.0). In the TR method, 98% of correct position on X-ray were correctly classified by USG. The agreement between X-ray and ultrasound categories with the cuff between the first and third tracheal rings, was very good [kappa (95% CI): 0.87 (0.70, 1.00), <em>p</em> ≤0.001)].</p></div><div><h3>Conclusion</h3><p>Bedside ultrasound is a good method to confirm ETT depth in children. The tracheal ring method had the best diagnostic accuracy and is easy to perform. The new method using cricoid cuff distance needs further validation in different ICU settings.</p></div>","PeriodicalId":55536,"journal":{"name":"American Journal of Emergency Medicine","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Emergency Medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0735675724003991","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Chest X-ray, the established standard of confirming endotracheal tube (ETT) position, has important drawbacks including radiation exposure. Point-of-care airway ultrasound, which has been insufficiently studied in children, can overcome these problems.

Materials and methods

This was a prospective cross-sectional study done on children aged 2 months to 17 years undergoing intubation with cuffed ETT in the PICU. The ETT cuff was filled with saline and three ultrasonographic techniques were used– 1) Suprasternal (SS) method 2) Cricoid (CC) metho and 3) Tracheal ring (TR) method. Position of the ETT as determined by ultrasound and X-ray were compared. The main outcomes were sensitivity, specificity, and area under curve (AUC) for ultrasound-based methods vs. X-ray. For the TR method, concordance between the X-ray and ultrasound categories were taken.

Results

Total 62 patients were enrolled. The sensitivity and specificity of SS method were 71% (95% CI: 57–83%) and 100% (40–100%). The CC distance method had an AUC of 0.94 (95% CI: 0.86, 1.0). In the TR method, 98% of correct position on X-ray were correctly classified by USG. The agreement between X-ray and ultrasound categories with the cuff between the first and third tracheal rings, was very good [kappa (95% CI): 0.87 (0.70, 1.00), p ≤0.001)].

Conclusion

Bedside ultrasound is a good method to confirm ETT depth in children. The tracheal ring method had the best diagnostic accuracy and is easy to perform. The new method using cricoid cuff distance needs further validation in different ICU settings.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
气道超声在确认重症儿童气管插管深度方面的诊断准确性
背景胸部 X 光检查是确认气管导管(ETT)位置的既定标准,但存在辐射等重要缺点。材料和方法这是一项前瞻性横断面研究,研究对象是在重症监护病房接受带袖带 ETT 插管的 2 个月至 17 岁儿童。ETT 袖套内注入生理盐水,并使用三种超声波技术:1)胸骨上(SS)法;2)环状(CC)法;3)气管环(TR)法。对超声和 X 光确定的 ETT 位置进行了比较。主要结果是超声法与 X 光法的灵敏度、特异性和曲线下面积(AUC)。对于 TR 方法,X 射线和超声类别之间的一致性被考虑在内。SS 方法的敏感性和特异性分别为 71%(95% CI:57-83%)和 100%(40-100%)。CC 距离法的 AUC 为 0.94 (95% CI: 0.86, 1.0)。在 TR 方法中,X 光片上 98% 的正确位置被 USG 正确分类。X 射线和超声分类与第一和第三气管环之间的袖带之间的一致性非常好[kappa (95% CI): 0.87 (0.70, 1.00), p ≤0.001]。气管环法的诊断准确率最高,且操作简便。使用环状袖带距离的新方法需要在不同的重症监护室环境中进一步验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.00
自引率
5.60%
发文量
730
审稿时长
42 days
期刊介绍: A distinctive blend of practicality and scholarliness makes the American Journal of Emergency Medicine a key source for information on emergency medical care. Covering all activities concerned with emergency medicine, it is the journal to turn to for information to help increase the ability to understand, recognize and treat emergency conditions. Issues contain clinical articles, case reports, review articles, editorials, international notes, book reviews and more.
期刊最新文献
Gabapentinoid prescribing patterns and predictors utilizing neural networks:Comment. Why is oral diltiazem protocol more effective than intravenous protocol for acute rate control in the emergency department? Epidemiology of heart failure presentations to United States emergency departments from 2016 to 2023. Characterizing emergency department surgical airway placement in the setting of trauma - A reply with a data-in-brief analysis of the pediatric cricothyrotomy. An update of the severe trauma scoring system using the Korean National Emergency Department Information System (NEDIS) database.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1