Alexandre Caubère, Stella Rutigliano, Samuel Bourdon, John Erickson, Moreno Morelli, Moby Parsons, Lionel Neyton, Marc-Olivier Gauci
{"title":"The effect of humeral tray thickness on glenohumeral loads in a reverse shoulder 'smart' implant.","authors":"Alexandre Caubère, Stella Rutigliano, Samuel Bourdon, John Erickson, Moreno Morelli, Moby Parsons, Lionel Neyton, Marc-Olivier Gauci","doi":"10.1007/s00264-024-06282-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to observe the effects of changing humeral tray thickness on the resultant of intraoperative glenohumeral joint loads using a load-sensing system (LSS).</p><p><strong>Methods: </strong>An rTSA was performed on fresh frozen full-body cadaver shoulders by using an internal proprietary LSS on the humeral side. The glenohumeral loads (Newtons) and the direction of the resultant force applied on the implant were recorded during four standard positions (External rotation, Extension, Abduction, Flexion) and three \"complex\" positions of Activity Daily Life (\"behind back\", \"overhead reach\" and \"across chest\"). For each position, the thickness was increased from 0 to 6 mm in a continuous fashion using the adjustment feature of the humeral system. Each manoeuvre was repeated three times.</p><p><strong>Results: </strong>All shoulder positions showed a high repeatability of the glenohumeral load magnitude measured with an intra-class correlation coefficient of over 0.9. For each position, we observed a strong but no linear correlation between humeral tray thickness and joint loads. It was a cubical correlation (r<sub>s</sub> = 0,91) with a short ascending phase, then a plateau phase, and finally a phase with an exponential growth of the loads on the humeral implant. In addition, an increase in trail-poly thickness led to a recentering of force application at the interface of the two glenohumeral implants.</p><p><strong>Conclusion: </strong>This study provides further insight into the effects of humeral implant thickness on rTSA glenohumeral joint loads during different positions of the arm. Data obtained using this type of device could guide surgeons in finding the proper implant balance during rTSA.</p>","PeriodicalId":14450,"journal":{"name":"International Orthopaedics","volume":" ","pages":"2881-2889"},"PeriodicalIF":2.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00264-024-06282-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The aim of this study was to observe the effects of changing humeral tray thickness on the resultant of intraoperative glenohumeral joint loads using a load-sensing system (LSS).
Methods: An rTSA was performed on fresh frozen full-body cadaver shoulders by using an internal proprietary LSS on the humeral side. The glenohumeral loads (Newtons) and the direction of the resultant force applied on the implant were recorded during four standard positions (External rotation, Extension, Abduction, Flexion) and three "complex" positions of Activity Daily Life ("behind back", "overhead reach" and "across chest"). For each position, the thickness was increased from 0 to 6 mm in a continuous fashion using the adjustment feature of the humeral system. Each manoeuvre was repeated three times.
Results: All shoulder positions showed a high repeatability of the glenohumeral load magnitude measured with an intra-class correlation coefficient of over 0.9. For each position, we observed a strong but no linear correlation between humeral tray thickness and joint loads. It was a cubical correlation (rs = 0,91) with a short ascending phase, then a plateau phase, and finally a phase with an exponential growth of the loads on the humeral implant. In addition, an increase in trail-poly thickness led to a recentering of force application at the interface of the two glenohumeral implants.
Conclusion: This study provides further insight into the effects of humeral implant thickness on rTSA glenohumeral joint loads during different positions of the arm. Data obtained using this type of device could guide surgeons in finding the proper implant balance during rTSA.
期刊介绍:
International Orthopaedics, the Official Journal of the Société Internationale de Chirurgie Orthopédique et de Traumatologie (SICOT) , publishes original papers from all over the world. The articles deal with clinical orthopaedic surgery or basic research directly connected with orthopaedic surgery. International Orthopaedics will also link all the members of SICOT by means of an insert that will be concerned with SICOT matters.
Finally, it is expected that news and information regarding all aspects of orthopaedic surgery, including meetings, panels, instructional courses, etc. will be brought to the attention of the readers.
Manuscripts submitted for publication must contain a statement to the effect that all human studies have been approved by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted.
Reports of animal experiments must state that the "Principles of laboratory animal care" (NIH publication No. 85-23, revised 1985) were followed, as well as specific national laws (e.g. the current version of the German Law on the Protection of Animals) where applicable.
The editors reserve the right to reject manuscripts that do not comply with the above-mentioned requirements. The author will be held responsible for false statements or for failure to fulfil the above-mentioned requirements.