Rotational Stability and Visual Performance of Aberration-Free, Hydrophobic Acrylic Monofocal Toric IOL with Enhanced Material.

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY Journal of cataract and refractive surgery Pub Date : 2024-09-04 DOI:10.1097/j.jcrs.0000000000001540
William F Wiley, Alice T Epitropoulos, Jeffrey Whitman, Eva Liang, Ehsan Sadri, George Lau
{"title":"Rotational Stability and Visual Performance of Aberration-Free, Hydrophobic Acrylic Monofocal Toric IOL with Enhanced Material.","authors":"William F Wiley, Alice T Epitropoulos, Jeffrey Whitman, Eva Liang, Ehsan Sadri, George Lau","doi":"10.1097/j.jcrs.0000000000001540","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the rotational stability and visual performance of the enVista toric intraocular lens (IOL) (MX60ET) in cataract patients with pre-existing astigmatism.</p><p><strong>Setting: </strong>6 US sites.</p><p><strong>Design: </strong>Prospective, multicenter.</p><p><strong>Methods: </strong>Cataract patients ≥18 years with pre-existing astigmatism (0.77 D to 4.53 D) underwent phacoemulsification and implantation of enVista toric IOL (MX60ET). Outcome measures were the proportion of patients with absolute IOL axis rotation of ≤5°, uncorrected and corrected distance visual acuities (UDVA and CDVA) at 4 m, uncorrected intermediate visual acuity (UIVA) at 66 cm, manifest refraction, and adverse events (AEs). The patients were followed up on Days 1-2, 7-14, 30-60, and 120-180.</p><p><strong>Results: </strong>Mean astigmatism of 101 eyes (101 subjects) reduced from 1.47 ± 0.64 D preoperatively to 0.38 ± 0.38 D at Days 120-180 (p <0.001) with 88.1% (N=89/101) of eyes achieving astigmatism within 0.75 D. Mean postoperative UDVA and UIVA were 0.10 ± 0.16 and 0.25 ± 0.15 logMAR respectively. While 79.2% (N=80/101) of patients had postoperative UDVA of 20/32 or better, 63.9% (N=62/97) had UIVA of 20/40 or better. The mean toric IOL rotation from the operative visit to Days 30-60 was 1.97 ± 2.06° with 97.4% (N=74/76) of eyes showing toric IOL rotation of 5˚ or less.</p><p><strong>Conclusion: </strong>The enhanced enVista toric IOL (MX60ET) demonstrated excellent rotational stability and astigmatic outcomes indicating good efficacy of the IOL for the correction of astigmatism during cataract surgery.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556826/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001540","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the rotational stability and visual performance of the enVista toric intraocular lens (IOL) (MX60ET) in cataract patients with pre-existing astigmatism.

Setting: 6 US sites.

Design: Prospective, multicenter.

Methods: Cataract patients ≥18 years with pre-existing astigmatism (0.77 D to 4.53 D) underwent phacoemulsification and implantation of enVista toric IOL (MX60ET). Outcome measures were the proportion of patients with absolute IOL axis rotation of ≤5°, uncorrected and corrected distance visual acuities (UDVA and CDVA) at 4 m, uncorrected intermediate visual acuity (UIVA) at 66 cm, manifest refraction, and adverse events (AEs). The patients were followed up on Days 1-2, 7-14, 30-60, and 120-180.

Results: Mean astigmatism of 101 eyes (101 subjects) reduced from 1.47 ± 0.64 D preoperatively to 0.38 ± 0.38 D at Days 120-180 (p <0.001) with 88.1% (N=89/101) of eyes achieving astigmatism within 0.75 D. Mean postoperative UDVA and UIVA were 0.10 ± 0.16 and 0.25 ± 0.15 logMAR respectively. While 79.2% (N=80/101) of patients had postoperative UDVA of 20/32 or better, 63.9% (N=62/97) had UIVA of 20/40 or better. The mean toric IOL rotation from the operative visit to Days 30-60 was 1.97 ± 2.06° with 97.4% (N=74/76) of eyes showing toric IOL rotation of 5˚ or less.

Conclusion: The enhanced enVista toric IOL (MX60ET) demonstrated excellent rotational stability and astigmatic outcomes indicating good efficacy of the IOL for the correction of astigmatism during cataract surgery.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用增强型材料的无像差疏水丙烯酸单焦散光人工晶体的旋转稳定性和视觉效果。
目的:评估 enVista 散光眼内透镜 (IOL) (MX60ET) 在已有散光的白内障患者中的旋转稳定性和视觉表现:设计:前瞻性、多中心:设计:前瞻性、多中心方法:方法:年龄≥18 岁、原有散光(0.77 D 至 4.53 D)的白内障患者接受超声乳化手术,并植入 enVista 散光人工晶体 (MX60ET)。结果测量指标为人工晶体轴绝对旋转≤5°的患者比例、4 米处未校正和校正远视力(UDVA 和 CDVA)、66 厘米处未校正中间视力(UIVA)、明显屈光度和不良事件(AEs)。在第 1-2、7-14、30-60 和 120-180 天对患者进行了随访:结果:101 只眼睛(101 例受试者)的平均散光从术前的 1.47 ± 0.64 D 降低到 120-180 天时的 0.38 ± 0.38 D(P增强型 enVista 散光人工晶体 (MX60ET) 显示出卓越的旋转稳定性和散光效果,表明该人工晶体在白内障手术中矫正散光的效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
期刊最新文献
Ocular Shape of Cataract with Retinitis Pigmentosa: A Case-Control Study. Intraocular Lens Rotational Stability after Cataract Surgery with and without Primary Posterior Continuous Curvilinear Capsulorrhexis. Risk of Zonular Dialysis in Fellow-Eye Cataract Surgeries: A Multicenter Comparative Study. Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema. Analysis of the ESCRS calculator's prediction accuracy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1