Miguel Carreño;Jie Song;Oriol Gomis-Bellmunt;Robert Griñó
{"title":"Design-Oriented Large-Signal Stability Analysis of Synchronous Reference Frame Phase-Locked Loop","authors":"Miguel Carreño;Jie Song;Oriol Gomis-Bellmunt;Robert Griñó","doi":"10.1109/TPWRD.2024.3454533","DOIUrl":null,"url":null,"abstract":"The Synchronous Reference Frame Phase-Locked Loop is a central component of grid-following Voltage Source Converters. Previous research has shown that the differential equation introduced by this loop is a swing equation, similar to that of the synchronous machine. This paper analyzes the large-signal stability of a single converter connected to an infinite-bus system. The outcome is a boundary in the plane of the parameters separating a region of insufficient damping and a region of sufficient damping. Moreover, the boundaries of stability from the small-signal analysis are also included for completeness. The findings are validated via time-domain simulation in EMT models.","PeriodicalId":13498,"journal":{"name":"IEEE Transactions on Power Delivery","volume":"40 3","pages":"1235-1243"},"PeriodicalIF":3.7000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10664459","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Power Delivery","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10664459/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
The Synchronous Reference Frame Phase-Locked Loop is a central component of grid-following Voltage Source Converters. Previous research has shown that the differential equation introduced by this loop is a swing equation, similar to that of the synchronous machine. This paper analyzes the large-signal stability of a single converter connected to an infinite-bus system. The outcome is a boundary in the plane of the parameters separating a region of insufficient damping and a region of sufficient damping. Moreover, the boundaries of stability from the small-signal analysis are also included for completeness. The findings are validated via time-domain simulation in EMT models.
期刊介绍:
The scope of the Society embraces planning, research, development, design, application, construction, installation and operation of apparatus, equipment, structures, materials and systems for the safe, reliable and economic generation, transmission, distribution, conversion, measurement and control of electric energy. It includes the developing of engineering standards, the providing of information and instruction to the public and to legislators, as well as technical scientific, literary, educational and other activities that contribute to the electric power discipline or utilize the techniques or products within this discipline.