Evaluation of a vacuum insulated temperature calibration device to calibrate thermistor characteristics for skin cancer diagnosis

IF 0.4 4区 工程技术 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Electrical Engineering in Japan Pub Date : 2024-06-12 DOI:10.1002/eej.23471
Homei Fujita, Takashi Nonaka, Yasushi Hosokawa, Takuma Kogawa, Fuhui Guo, Yuya Iseki, Miyo Yokota, Takahiro Okabe, Shigenao Maruyama
{"title":"Evaluation of a vacuum insulated temperature calibration device to calibrate thermistor characteristics for skin cancer diagnosis","authors":"Homei Fujita,&nbsp;Takashi Nonaka,&nbsp;Yasushi Hosokawa,&nbsp;Takuma Kogawa,&nbsp;Fuhui Guo,&nbsp;Yuya Iseki,&nbsp;Miyo Yokota,&nbsp;Takahiro Okabe,&nbsp;Shigenao Maruyama","doi":"10.1002/eej.23471","DOIUrl":null,"url":null,"abstract":"<p>Recent methods using thermistors as an early detection of skin cancer require the higher resolution of 5 mK. Previously, the authors developed a vacuum insulated temperature device that calibrates the resistance temperature characteristics of thermistors, so that it improves the temperature resolution and accuracy of skin cancer diagnosis. In this study, the operational methods of the calibration system were compared for improving further accuracy using the temperature calibration device and the oil tank calibration device. The results of the comparison indicated that the temperature calibration device is probably as accurate as the oil tank calibration device.</p>","PeriodicalId":50550,"journal":{"name":"Electrical Engineering in Japan","volume":"217 3","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering in Japan","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/eej.23471","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Recent methods using thermistors as an early detection of skin cancer require the higher resolution of 5 mK. Previously, the authors developed a vacuum insulated temperature device that calibrates the resistance temperature characteristics of thermistors, so that it improves the temperature resolution and accuracy of skin cancer diagnosis. In this study, the operational methods of the calibration system were compared for improving further accuracy using the temperature calibration device and the oil tank calibration device. The results of the comparison indicated that the temperature calibration device is probably as accurate as the oil tank calibration device.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估用于校准皮肤癌诊断热敏电阻特性的真空绝热温度校准装置
最近使用热敏电阻作为皮肤癌早期检测的方法需要 5 mK 的较高分辨率。此前,作者开发了一种真空绝缘温度装置,可校准热敏电阻的电阻温度特性,从而提高皮肤癌诊断的温度分辨率和准确性。在这项研究中,为了进一步提高准确性,使用温度校准装置和油箱校准装置对校准系统的操作方法进行了比较。比较结果表明,温度校准装置可能与油箱校准装置一样准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Electrical Engineering in Japan
Electrical Engineering in Japan 工程技术-工程:电子与电气
CiteScore
0.80
自引率
0.00%
发文量
51
审稿时长
4-8 weeks
期刊介绍: Electrical Engineering in Japan (EEJ) is an official journal of the Institute of Electrical Engineers of Japan (IEEJ). This authoritative journal is a translation of the Transactions of the Institute of Electrical Engineers of Japan. It publishes 16 issues a year on original research findings in Electrical Engineering with special focus on the science, technology and applications of electric power, such as power generation, transmission and conversion, electric railways (including magnetic levitation devices), motors, switching, power economics.
期刊最新文献
Issue Information Development of fatigue prediction system for bogie frame using a dynamic analysis model based on high-speed and high-precision stress estimation method Design and improvement of torque characteristics of half-wave rectified variable field flux motor with axial gap structure Evaluation of a vacuum insulated temperature calibration device to calibrate thermistor characteristics for skin cancer diagnosis Centralized control of large-scale wind farm for system frequency stabilization of the power system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1