Yazan Mohsen, Nora Großmann, Jennifer Draheim, Marc Horlitz, Florian Stöckigt
{"title":"Coronary sinus signal amplitude: A predictor of the atrial substrate and low voltage areas.","authors":"Yazan Mohsen, Nora Großmann, Jennifer Draheim, Marc Horlitz, Florian Stöckigt","doi":"10.1111/pace.15070","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Low voltage areas (LVA) are pivotal in atrial fibrillation (AF) pathogenesis, influencing local left atrial LA excitation and perpetuating AF occurrences. While pulmonary vein isolation (PVI) with cryo-balloon (CB) ablation is effective for AF, it doesn't provide insights into the LA substrate or detect LVA, which affects ablation success rates. This study examines whether LA voltage and LVAs can be anticipated by analyzing the voltage signal amplitude at the coronary sinus (CS) catheter, which is standard in CB and radiofrequency ablation procedures.</p><p><strong>Methods: </strong>A retrospective analysis of 284 patients with recurrent AF undergoing RF catheter ablation was conducted at a high-volume EP center in Germany. The correlation between LA voltage and LVA with the CS signal was explored.</p><p><strong>Results: </strong>The signal amplitude in the CS significantly correlated with voltage in LA walls, particularly in the proximal CS (correlation coefficient ρ = 0.81, p < 0.001). A CS signal cut-off of 1.155 mV effectively predicted severe atrial LVAs (>40%) with a sensitivity of 90.7% and a specificity of 100%. While a threshold of 1.945 mV identified patients with no significant atrial LVAs (<5%) with a sensitivity of 88% and a specificity of 50% (AUC: 0.81, 95% CI: 0.71-0.89, p < 0.001).</p><p><strong>Conclusion: </strong>The CS signal amplitude is associated with the LA voltage. Due to its potential as a diagnostic tool for atrial LVAs, the signal amplitude in the CS could provide valuable information about the LA substrate, especially when 3D mapping is not feasible.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15070","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Low voltage areas (LVA) are pivotal in atrial fibrillation (AF) pathogenesis, influencing local left atrial LA excitation and perpetuating AF occurrences. While pulmonary vein isolation (PVI) with cryo-balloon (CB) ablation is effective for AF, it doesn't provide insights into the LA substrate or detect LVA, which affects ablation success rates. This study examines whether LA voltage and LVAs can be anticipated by analyzing the voltage signal amplitude at the coronary sinus (CS) catheter, which is standard in CB and radiofrequency ablation procedures.
Methods: A retrospective analysis of 284 patients with recurrent AF undergoing RF catheter ablation was conducted at a high-volume EP center in Germany. The correlation between LA voltage and LVA with the CS signal was explored.
Results: The signal amplitude in the CS significantly correlated with voltage in LA walls, particularly in the proximal CS (correlation coefficient ρ = 0.81, p < 0.001). A CS signal cut-off of 1.155 mV effectively predicted severe atrial LVAs (>40%) with a sensitivity of 90.7% and a specificity of 100%. While a threshold of 1.945 mV identified patients with no significant atrial LVAs (<5%) with a sensitivity of 88% and a specificity of 50% (AUC: 0.81, 95% CI: 0.71-0.89, p < 0.001).
Conclusion: The CS signal amplitude is associated with the LA voltage. Due to its potential as a diagnostic tool for atrial LVAs, the signal amplitude in the CS could provide valuable information about the LA substrate, especially when 3D mapping is not feasible.
期刊介绍:
Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.